V-tech DT601FE/KP User manual

English
User Manual
2-Wire Video Outdoor Station
DT601FE/KP
1
4 5 6
98
0 #
7
2 3
*
DT-ENG-601FE/KP-V1 151019


Contents
1.Parts and Functions............................................................................................. 1
2.Terminal Descriptions .......................................................................................... 1
3.Door Station Mounting......................................................................................... 2
4.System Wiring and Connections ......................................................................... 3
5.Fisheye Camera Function ................................................................................... 7
6. Functions Setting Up .......................................................................................... 7
7.Unlock Operations............................................................................................... 15
8. Precaustions....................................................................................................... 15
9.Specications ...................................................................................................... 15
10.Cables Requirements........................................................................................ 16

-1-
1.Parts and Functions
DT601FE/KP Side View Mounting box
220 mm
120 mm
1
4 5 6
98
0 #
7
2 3
*
Camera Lens
Speaker
Touch Sensitive
Digital Keypad
Nameplate
Call Button
Microphone
Night Light
Screws for panel
mounting
1
4 5 6
98
0 #
7
2 3
*
2.Terminal Descriptions
1 2 3
Lock Control Jumper
BUS
PL
S+ S-
Main Connect Port
•Lock Control Jumper: To select the lock type.
•Main Connect Port: To connect the bus line and the electronic locks.
•BUS: Connect to the bus line, no polarity.
•PL: External lock power input, connect to the power positive(power +).
•S+: Lock power(+) output.
•S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).

-2-
3.Door Station Mounting
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
1 2
43
Drill a hole in the wall to match the size of the
mounting box and attach to the wall.
Attach the panel to the mounting box and
use screws supplied to fix the panel
Connect the cable correctly
Placing Name Label
Use a screwdriver to unscrew the screw,
and cock the host , then Placing Name
Label.
DT601FE/KP Mounting

-3-
Basic Connection
4.System Wiring and Connections
BUS(IM) BUS(DS)
PC6
AC~
-
+
L1 L2 PL S+ S-
Doorbell Button
Switch
1 2 3
ON
DIPS
Electric Lock Connection
EB
*
LOCK
BUS PL S+S-
Jumper position in 2-3
1 2 3
Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power-on-to-unlock type
should be used.
2. The door lock is limited to 12V, and holding
current must be less than 250mA.
3. The door lock control is not timed from Exit
Button(EB).
4. The Unlock Mode Parameter of Monitor
must be set to 0 (by default).

-4-
LOCK
Take off the Jumper
POWER
SUPPLY
BUS PL S+S-
Unlock parameter setting(set in monitor)
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according
to the lock.
2. The inside relay contact is restricted to AC or DC
24V/1A.
3. The jumper must be taken off before connecting.
4. Setup the Unlock Mode of Monitor for different
lock types.
•Power-on-to-unlock type:Unlock Mode=0
(by default)
•Power-off-to-unlock type:Unlock Mode=1
Note:
1.must connect DT601(F)/KP correctly before setting.
2.the parameter will be saved in DT601(F)/KP automatically,so you need only set on one monitor.
3.Here we take DT47M(the monitor) for example, please refer to the corresponding user manual.
1.Touch icon on
main menu page.
2.Touch UNLOCK
button and hold for 2s.
3.A digital keypad will be
shown.
About
Local Address 00.00
Video Standard AUTO
System Verson 00.01.00
Display Driver 1.0
Front 1.0
UI 1.0
INSTALLER SETUP 123
_

-5-
Multi Door Stations Connection
100~240VAC
DBC4A
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
PC6
AC~
4# Camera
L1 L2 PL S+ S-
(Device Address:3)
3# Camera
L1 L2 PL S+ S-
(Device Address:2)
2# Camera
L1 L2 PL S+ S-
(Device Address:1)
1# Camera
L1 L2 PL S+ S-
(Device Address:0)
Basic IN-OUT Wiring Mode
Multi Monitors Connection
Code=14Code=15
(Device Address:0)
BUS(IM) BUS(DS)
PC6
AC~
100~240VAC
Code=0
NOTE:Here we take DT47M(the monitor) for example.
1
4 5 6
98
0 #
7
2 3
*

-6-
With DBC4A Wiring Mode
Code=0
OFF ON
OFF ON
DBC4A
A B C D
DBC4A
A B C D
Impedance
switch
Impedance
switch
(Device Address:0)
NOTE:Here we take DT47M(the monitor) for example.
100~240VAC
BUS(IM) BUS(DS)
PC6
AC~
Code=2
Code=1
Code=3
Code=12
Code=14
Code=13
Code=15
1
4 5 6
98
0 #
7
2 3
*

-7-
Note that this function requires the monitor with sheye function to support.
Press CALL button on outdoor station and the Monitor rings with screen on, or during
monitoring state, the visitors' image will be shown on screen:
In ve direction pad mode, you can zoom in or zoom out the range of monitoring to
identify everyone at the entrance.
When you press any lattice of
the ve direction pad, the lattice
screen will be enlarged to full
screen.
Press to return to the full screen
mode; Press , , to move, in
order to see individuals up close.
5. Fisheye Camera Function
6. Functions Setting Up
This section explains the settings of each function,please refer to the following table:
About the setting mode:
Input the master code to switch to the setting mode, and input the corresponding setting code to perform the
settings for the function you want. After settings have been made, input the following setting codes to continue the
setting operation. Press " " to exit the setting mode.
•The example is set as cancel button and # as conrm button,please refer to */# function
setting for detail information.
•Forbid to slide to touch the digital keypad,it may cause mistaken key,the correct operation is
using your nger to press the digital you desired.
•You should press“confirm”button after finish inputting the code number each
time,otherwise,the operation will be canceled automatically in 10s.

-8-
Order Setting items Setting range Default value Setting code
1 Reset all settings 1234 -00
2 Setting the master code 1 ~ 12 digits
Valid keys:0 ~ 9 1234 01
3Setting the key
illumination time
10 to 99 seconds/
continually lit 10 seconds 02
4 Setting the unlock time 01 to 99 seconds 1 seconds 03
5 Setting the unlock mode 0:opened/1:closed opened 04
6Operation tone settings 0:on/1:off on 05
7 Reset code settings 1234 - 06
8 &# function settings 0:Normal/1:Reverse Normal 07
9Call tone settings 0:Enable/1:Disable Enable 08
10 Interference resistant
grade settings Valid keys:0 ~ 5 2 09
11 MIC Adjustment Valid keys:0~9 7 10
12 SPK Adjustment Valid keys:0~9 4 11
13 Display Scene Valid keys:0~2 0 12
14 Night Light Level Valid keys:0~5 4 13
15 Device Address Valid keys:0~3 0 14
16 Reserve(not used) Reserve Reserve 15~17
17 Setting the code
forTemporary1
1 ~ 12 digits
Valid keys:0~9 - 18
18 Setting the code
forTemporary2
1 ~ 12 digits
Valid keys:0~9 - 19
19 Setting the code for user
group1
1 ~ 12 digits
Number of codes:40
Valid keys:0~9
- 20~59
20 Setting the code for user
group2
1 ~ 12 digits
Number of codes:40
Valid keys:0~9
- 60~99
21 Work Mode 0:A partment/1:Villa 1(villa) 100
22 Call Address Valid keys: 0 - 9 00 101

-9-
1
4 5 6
98
0 #
7
*
2 3
Input the master code.
(Default: [ ] +[#] )
- All settings will restore to their
default value.
-
When power on or activate
the reset all setting item,the
keypad checking will carry out,
during this time,the key
illumination will blink and the
touching operation is forbidden,
after finish checking,the key
illumination will stop blinking
and sent out a long sound of beep
- The master code is allowed 1~12
digits,the same code cannot be set
for both the user code and the
master code,it is recommended
that you modify the default master
code.
- The unlock time can be set on
both monitor and door station,
and the valid value is the number
you set last time.
(white)
The color of key indicator
Beep+, Beep
Beep+, Beep Beep+, Beep Beep+, Beep Beep+, Beep
Beep+ Beep+ Beep+ Beep+
Inputting of code (ex.: 10)
range:00 or 10~99
Inputting of code (ex.: 09)
range:01~99
3.Setting the key
illumination time
4.Setting the
unlock time
2.Setting the master code
(Default 1234) (Default 10s) (Default 1s)
Inputting of new master code
(ex.: 4321)(1~12 digits)
Input the setting code.
Inputting of code
Input the setting code.
1.Reset all settings
00+#
1234+# 4321+#
01+#
10+# 09+#
Input the setting code.
02+#
Input the setting code.
03+#
- If the key illumination time is set
to 00,the key illumination will light
up all the time when power on.
- If the key illumination time is set to
10~99,the key illumination will light
up for 10~99 seconds.At this mode,
the key illumination lights off in
standby mode, touching any digital
key can illuminate,but this is the
invalid digital.
(yellow)
The color of key indicator
(yellow)
The color of key indicator
(yellow)
The color of key indicator
(yellow)
The color of key indicator
The color of key indicator
(green white)
The color of key indicator The color of key indicator The color of key indicator
(green white) (green white)(green white)
-
When the “ cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
-
When there isn’t any operation in 10s, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
Beep, Beep+
*
(The color
of standby)
The color of
key indicator
-
When setting failure, the color of key indicator will turn red , the buzzer beeps.
Each operation is indicated by the lighting up of the
different color of digital key and nameplate , and by the
sounding of the buzzer.

-10-
Input the master code.
(Default: [ ] +[#]) Beep+, Beep
Beep+, Beep Beep+, Beep Beep+, Beep Beep+, Beep
Beep+
Beep+Beep+ Beep+
7.Reset code setting 8. &# function setting6.Setting operation tone
(Default ON) (Default Normal)(Default 0(opened))
Input the setting code.
Inputting of code
Input the setting code.
5.Setting the unlock mode
04+# 05+#
range:0:(open)/1:(close)
1+#
0/1 0/1 0/1
1+# 1+#1234+#
Input the setting code.
06+#
Input the setting code.
07+#
(ex.: 1)
Inputting of code Inputting of code Inputting of code
range:0:(on)/1:(off)
(ex.: 1)
range:0:(normal)/1:(reverse)
(ex.: 1)
*
*
*
- The unlock mode can be set on
both monitor and door station,
and the valid value is the number
you set last time.
- When the operation tone is
set to 0,pressing the digital
keypad will sent out a sound
of beep.
- When the operation tone is
set to 1,pressing the digital
keypad will blink one time.
- Cancel all the passwords except
the master code.
- Restore the master code to
default value(1,2,3,4)
- When the item is set to 0,press
the button to cancel the input,
and press the # button to confirm
the input.
- When the item is set to 1,press
the # button to cancel the input,
and press the button to confirm
the input .
(white)
The color of key indicator
(yellow)
The color of key indicator
The color of key indicator
(yellow)
The color of key indicator
The color of key indicator
(yellow)
The color of key indicator
The color of key indicator
(yellow)
The color of key indicator
The color of key indicator
(green white)
(green white) (green white) (green white)
-
When the “ cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
-
When there isn’t any operation in 10s, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
Beep, Beep+
*
(The color
of standby)
The color of
key indicator
-
When setting failure, the color of key indicator will turn red , the buzzer beeps.

-11-
Input the master code.
(Default: [ ] +[#]) Beep+, Beep
Beep+, Beep Beep+, Beep
Beep+ Beep+
10.Interference resistant
grade setting
Input the setting code.Input the setting code.
9. Call tone setting
08+#
0/1
1+#
09+#
Inputting of code (ex.: 3)
range:0~5
3+#
Inputting of code (ex.: 1)
range:0(enable)/1:(disable)
(Default 2)
(Default enable)
-
The larger you set the
interference resistant grade,
the stronger it will be,but the
sensitivity of the keypad will
be more lower.
- The interference resistant
grade setting also will activate
the keypad checking.
-
If the item is set to 0,the unit will
respond a call tone when pressing
the “CALL” button.
- If the item is set to 1, the unit will
have no responds when pressing
the “CALL” button.
(white)
The color of key indicator
(yellow)
The color of key indicator
The color of key indicator
(green white)
(yellow)
The color of key indicator
The color of key indicator
(green white)
Beep+, Beep
Beep+
11.IMC volume adjust
setting
Input the setting code.
10+#
Inputting of code (ex.: 5)
range:0~9
5+#
(Default:7)
(yellow)
The color of key indicator
The color of key indicator
(green white)
Beep+, Beep
Beep+
12.SPK volume adjust
setting
Input the setting code.
11+#
Inputting of code (ex.: 5)
range:0~9
5+#
(Default:4)
(yellow)
The color of key indicator
The color of key indicator
(green white)
- Unlock via password is still available even when the door station is
talking.
- When door station is talking, you can enter the Master code (the
LED turns white upon that) to activate the volume adjusting function:
MIC adjustment: 1 (up), 4 (down);
Sleaker adjustment: 3 (up), 6 (down).
-
When the “ cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
-
When there isn’t any operation in 10s, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
Beep, Beep+
*
(The color
of standby)
The color of
key indicator
-
When setting failure, the color of key indicator will turn red , the buzzer beeps.

-12-
Input the master code.
(Default: [ ] +[#]) Beep+, Beep
Beep+, Beep Beep+, Beep
Beep+ Beep+
14.Night light level
setting
Input the setting code.Input the setting code.
13. Display scene setting
12+#
0/1
1+#
13+#
Inputting of code (ex.: 3)
range:0~5
3+#
Inputting of code (ex.: 1)
range:0~2
(Default 4)
(Default 0)
- Night Light Level:0~5.
-The higher the number, the brighter
the night lights.
-
Scene0: Standby(blue), calling
(blue blinks rapidly), talking(blue
blinks slowly), unlock(green).
- Scene1: Standby(green), calling
(green blinks rapidly), talking
(greenblinks slowly), unlock(blue).
- Scene2: Standby(blue), calling
(yellow), talking(red), unlock(green).
(white)
The color of key indicator
(yellow)
The color of key indicator
The color of key indicator
(green white)
(yellow)
The color of key indicator
The color of key indicator
(green white)
Beep+, Beep
Beep+
15.Device address setting
Input the setting code.
14+#
Inputting of code (ex.: 0)
range:0~3
0+#
(Default:0 )
(yellow)
The color of key indicator
The color of key indicator
(green white)
-
Device address Settings:
0(device address:0),1(device
address:1),2(device address:2),
3(device address:3).
-
When the “ cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
-
When there isn’t any operation in 10s, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
Beep, Beep+
*
(The color
of standby)
The color of
key indicator
-
When setting failure, the color of key indicator will turn red , the buzzer beeps.

-13-
Input the master code.
(Default: [ ]+[#] ) Beep+, Beep
Beep+, Beep Beep+, Beep Beep+, Beep Beep+, Beep
Beep+ Beep+ Beep+ Beep
Inputting of code (ex.: 2011)
1~12 digits
Inputting of code (ex.: 2012)
1~12 digits
18.Setting the code
for user group1
19.Setting the code
for user group2
17.Setting the code
forTemporary2
Input the setting code.Input the setting code.
16.Setting the code
forTemporary1
18+# 19+# 21+# 60+#
2011+#
Inputting of code (ex.: 1006)
1~12 digits
1006+#
Inputting of code (ex.: 2011)
1~12 digits
2010+# 2012+#
Input the setting code.
(ex.:21)
Input the setting code.
(ex.:60)
20~59 60~99
- When input the correct temporary password to release the door,
the system will clear the temporary password after 60 seconds
automatically.But you should know that the password is valid within
60 seconds after inputing the correct temporary password
- The temporary1 is used to release the first lock,and the temporary
2 is used to release the second lock(the second lock need external
device to support).
- If the password length exceeds 12 digits, the system will sent out
the sound of “beep,beep,beep,beep”,and the digitals you input before
will be cleared at the same time.
- The temporary code can not be set the same as the master code
and user code.
- The user code group1 is used to release the first lock,and the user code
group2 is used to release the second lock(the second lock need external
device to support).
- The user code group1 and user code code group2 can contain 40
group passwords
- If the password length exceeds 12 digits, the system will sent out the
sound of “beep,beep,beep,beep”,and the digitals you input before will
be cleared at the same time.
- The user code can not be set the same as the master code and
temporary code.
(white)
The color of key indicator
(yellow)
The color of key indicator
The color of key indicator
(green white)
(yellow)
The color of key indicator
The color of key indicator
(green white)
(yellow)
The color of key indicator
The color of key indicator
(green white)
(yellow)
The color of key indicator
The color of key indicator
(green white)
-
When the “ cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
-
When there isn’t any operation in 10s, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
Beep, Beep+
*
(The color
of standby)
The color of
key indicator
-
When setting failure, the color of key indicator will turn red , the buzzer beeps.

-14-
Input the master code.
(Default: [ ]+[#] ) Beep+, Beep
Beep+, Beep Beep+, Beep
Beep+ Beep+
21.Call address setting
Input the setting code.Input the setting code.
20.Work mode setting
0+#
- Work mode setting:
0(a partment)/1:(villa).
(white)
The color of key indicator
(yellow)
The color of key indicator
The color of key indicator
(green white)
(yellow)
The color of key indicator
The color of key indicator
(green white)
100+# 101+#
(Default:villa:00,16;
a partment:00~31)
(Default:1/villa)
Inputting of code (ex.: 1)
range:0(a partment)/1:(villa)
0+#
Inputting of code (ex.: 1)
range:Valid keys: 0 - 9
- When the work mode is villa,the call
address:00 or 16.
- When the work mode is a partment,
the range of call
address:00~31.
-
When the “ cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
-
When there isn’t any operation in 10s, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
Beep, Beep+
*
(The color
of standby)
The color of
key indicator
-
When setting failure, the color of key indicator will turn red , the buzzer beeps.

-15-
7.Unlock Operations
When the registered user code has been input using the keypad (1~12 digits), the LED background
indicator lights up, the buzzer sounds,and the electric door strike is unlocked.(note that you should
press "#" button(if "#" button is set to conrm button) after input the unlock code)
•The time interval during which the button must be pressed is approximately 10 seconds. If the
time interval exceeds approximately 10 seconds, the input value will be cleared.
•If you make a mistake when inputting the user code,press the" cancel" button and input the user
code again.
•The release function is forbidden and the input operation is disabled for 60 seconds if 10 times
incorrect access codes are continuously attempted. During this time,the buzzer will continuously
sound about 8 times.
Unlocking of user code
1. During calling,pressing "cancel" button can cancel the calling
2. If input the incorrect access code,the buzzer will sound of beep,beep,beep
9.Specications
8. Precaustions
•Power Supply : DC 24V ;
•Power Consumption: Standby 40mA; Working status 160mA;
•Camera: Color ARS; 420 TV Lines;
•Unlocking time: 1~99s
•Lock Power supply: 12Vdc, 280mA(Internal Power);
•Number of relay circuits: 2(the second lock need external device to support)
•Mounting: Flush mounting
•Working temperature: -15ºC ~ +55ºC
•Dimension: 220(H)×120(W)×50(D)mm
•Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If
necessary, please use a little pure water or dilute soap water to clean the dust.
•The unit is weather resistant. However do not spray high pressure water on access control keypad directly.
Excessive moisture may cause problems with the unit.
•You must use the right adaptor which is supplied by the manufacture or approved by the manufacture..
•Pay attention to the high voltage inside the products, please refer service only to a trained and qualified
professional.

-16-
The farest monitor
B
A
C
DBC4A
monitor
monitor
monitor
with two or four monitors
100~240VAC
BUS(IM) BUS(DS)
PC6
AC~
1
4 5 6
98
0 #
7
2 3
*
10.Cables Requirements
The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the
maximum distance which the system can reach.
When Monitor quantity < 20
Cable Usage A B C
Twisted cable 2x0.75 mm260 60 30
Twisted cable 2x1 mm280 80 40
When Monitor quantity > 20
Cable Usage A B C
Twisted cable 2x1 mm270 30 20
Twisted cable 2x1.5 mm270 50 30
Note:If the monitor has been specied the distance,refer to the
parameter.

The design and specications can be modied without notice to the user. Right to interpret
and copyright of this manual are reserved.
DT-ENG-601FE/KP-V1 151019