Understanding before use
Dear customer, thank you for purchasing the NT-3 oxygen generator. Using it, there
will be a healthy and friendly atmosphere surrounding lucky you. If you can tell us
your product suggestions and service opinions, we will Would appreciate your help
very much.
Please read these instructions carefully, so that you can quickly and thoroughly
understand how to use this oxygen generator, and keep this instruction for future
reference or forwarding to any future users.
This manual explains and stipulates the operating conditions and performance,
specifications, operating environment requirements and test results of the pulse
oxygen enricher.
If you understand the following knowledge, you will be able to use theoxygen
generator specified in this manual more reasonably:
1. Rejuvenate brain activity;
2. Oxygen is used for skin care;
3. How does oxygen restore sub-health fatigue;
4. Reduce the harm of alcohol and cigarettes;
5. Softening and deodorizing;
6. Other related environmental and health information and products.
Product Features
Features of this product Adopting PSA's safe and reliable oxygen production
technology, the battery is separated from the host, which is convenient for users to
replace a larger or smaller battery pack, and is convenient for reasonable
arrangements when going out.
The small size, beautiful appearance, and efficient pulse oxygen supply are
especially suitable for users who need to move.
- 1 -

Start using oxygen generator
Preparation before use:
1. Before starting the oxygen generator for the first time, please familiarize yourself
with the main accessories, which will be used later.
2. Instructions for use of the adapter and battery
(1) Due to transportation control reasons, the external batteries only retain the
power for testing when they leave the factory, or there is no power at all. Therefore,
the battery needs to be fully charged before the first use.
(2) Battery charging method:
a. Connect one end of the AC adapter to 100~240VAC, and the other end to the
charging socket of the battery. At this time, the AC adapter indicator lights up in red,
indicating that the battery is charging, and the battery is fully charged for about 4-6
hours; when the AC adapter indicates When the light turns green, it indicates that
the battery is fully charged. At this time, you can disconnect the AC adapter and the
battery.
b. Connect one end of the AC adapter to 100~240VAC and the other end to the
charging socket of the battery. At the same time, connect the output end of the
battery to the power input socket of the oxygen enrichment machine, and then
press the power switch of the oxygen enrichment machine to start the machine.
Charge while oxygen. In this mode, the time to fully charge the battery is related to
the working gear of the machine, and the time to fully charge is about 4-10 hours.
The use of oxygen generator:
1. Please place the product correctly, ensure that the air inlet and outlet are
unobstructed, and the distance from the outside to other objects or walls is at least
10cm;
2. Connect the oxygen inhaler;
3. Connect the power input socket of this product to the output plug of the AC
adapter or external battery;
4. Press the power switch, the device will start the oxygen production of this product;
Important statement
1.This oxygen generator is for health maintenance and life quality improvement
purposes, and cannot be used as life extension or medical equipment.
2. Do not use the device before reading and understanding the contents of the
manual, otherwise it may cause injury or damage to the product due to improper
operation.
3. Do not smoke, light candles or use other open flames when using this equipment.
4. If you need to smoke, please follow the following important safety measures: turn
off the device, remove the oxygen tube, and leave the room of the device.
5. Please clearly place the sign of "oxygen generator, please do not smoke" in the
room with the equipment.
Receipt inspection
1. Check equipment and accessories
NO. Name QTY
1Main machine 1 unit
2AC adaptor 1 set
3Use manual 1 pcs
4Disposable oxygen inhaler 1 set
5External battery 1 pcs
6Diagonal shoulder bag 1 pcs
7Warranty card/certificate 1 pcs
8Car line 1 pcs
Please check whether it is sufficient according to the above list. If there is any
missing, please contact the sales to make up the difference or return the goods.
- 2 - - 3 -

5.The product is turned on and enters the power-on state, and immediately starts
pulse oxygen supply. There are four timing time periods to choose from, 40 minutes,
60 minutes, 80 minutes and 180 minutes, and it will automatically shut down when it
is used.
The use of nasal oxygen inhaler
1. Connect one end of the oxygen inhalation tube to the nasal inhaler and the other
end to the oxygen output port of the device.
2. When using the oxygen inhaler, the tube must be connected correctly and not
folded, so as not to inhale oxygen normally;
3. See the following
Specific operation
1. Take out the oxygen generator and insert the output plug of the power supply or
battery pack into the power socket of the oxygen generator. If it is from a low
temperature environment to a room temperature environment, it needs to be placed
for 4 hours before performing this operation, such as from outdoors-100C gets
indoor 200C, it needs to be placed for 4 hours before use.
2. Standard battery pack
3. Take out the nasal suction tube and insert the air inlet of the nasal suction tube
into the air outlet of the oxygen generator;
4.Put on the nasal straw, as shown in the picture below
5.Press the power switch button of the oxygen generator, you will hear a beep, and
the machine starts to work;
6.If you need to adjust the different use time, press the green SET button and
follow the instructions to set: 40 minutes, 60 minutes, 80 minutes, 180 minutes, a
total of 4 time levels;
The timing setting button only works when the machine
is turned on, and it cannot be used after the machine is
turned off.
On the left is the charger socket. The rubber cap
should be fastened when not in use to prevent short
circuit damage to the battery or accidents.
The one on the right is the output line, which can be
plugged into the power socket of the oxygen
generator to supply power to the oxygen generator.
The upper one is the air outlet connector, the lower one
is the power socket, which can be connected to a
battery pack or a power adapter
Turn on or turn off the button; in the off state, click
to turn on, and in the on state, click to
- 4 - - 5 -

After power on, the first gear will be on by default, press it again to turn on the
second gear, press the third time to turn on the third light; press the fourth time to
turn on the three lights at the same time;
Timing time indication: each light is on, indicating the corresponding timing time, if
three lights are on at the same time, the timing time is the sum of the three:
=40+60+80=180(min).
Available power supply
1. The external battery pack equipped with this product;
2. The AC adapter equipped with this product;
3. The 12V power supply of the car needs the on-board cable that is equipped with
this product.
7. If you need to stop working during use, just press the red power switch button, or
it will automatically stop working when it is time.
Precautions in use
1.To ensure better oxygen inhalation, please refer to the picture on the right to wear
the oxygen inhaler correctly. When wearing the oxygen inhaler, be careful not to
bend the pipeline to prevent the air path from being blocked.
2.Properly keep and place the battery pack to prevent accidents and help prolong
the life of the product;
3.Remind again, when using this product, do not smoke and keep away from open
flames;
4. Do not use as toys for children, and place them out of the reach of children to
prevent accidents when children play;
Cleaning and maintenance
1. Before cleaning the equipment, please unplug all external devices: such as AC
adapter, external battery, oxygen inhaler, and make sure that the equipment is
turned off.
2. Do not let the equipment get wet or let water enter the equipment. If water enters
the equipment accidentally, please stop using it immediately and contact the dealer
for handling;
3. If the equipment is not to be used for a long time, please wrap the host in a plastic
bag and seal it to prevent the performance of the machine from degr
4. Use at least once a week, no less than 1 hour each time
5. Please disconnect the power supply and battery in time after using the device
each time.
- 6 - - 7 -

Product Name: Oxygen Generator
Model number: NT-3
Scope of application: It is only used for health preservation and improving the
quality of life, not for medical treatment or life continuation.
Oxygen production method: pressure swing adsorption separation method (PSA
method)
Work rate: 30W
Input voltage: DC12V~16. 8V
Four levels of timing: 40 minutes, 60 minutes, 80 minutes, 180 minutes
Product size: 20.5 * 9.5 * 13cm
Product net weight: 1.4Kg
Maximum oxygen production flow (equivalent): 3L/min
Oxygen concentration: 32.5%±2.5(v/v)
Standard battery pack capacity: 2500mAH 14.8V,the highest voltage is 16.8V
The longest use time: 2.5h.
Change a new power
or battery
1
Change a new power
or battery
2
Change a new power
or battery
3
Change a new power
board
4
Not working Not connected
to power supply
Power broken
The charger
doesn’t work
Power line is broken
No AC
Contact the agent or
manufacturer to deal
with it.
5Internal damage
Not working Internal failure
of the machine
Change the correct
power supply
6Incorrect or damaged
power supply
The first light
flashes slowly
The power
supply is
abnormal
Change the correct
power supply
7Incorrect or damaged
power supply
The first light
flashes quickly
The power
supply is
abnormal
Smooth the air inlet
and outlet of the
machine and wait for
the temperature of
the machine to drop
to normal.
8Poor heat dissipation
The second light
flashes slowly
High internal
temperature
Put the machine in
an envi r o n m ent
h i g h e r t h a n 5
degrees Celsius for
4 hours be f o r e
using it.
9
Working environment
temperature is too low
The second light
flashes quickly
The ambient
temperature
is too low
No
10 No
There is a rhythm
like breathing
Normal working
sound
Poor heat dissipation,
the machine can still
work, this time will
increase the heat
dissipation capacity.
11
Poor heat dissipation
Fan noise is
too loud
Temperature
is too high
Product specifications Troubleshooting for general problems
NO. Phenomenon Problems Reason Solution
- 8 - - 9 -

A notice:
Quality assurance and disclaimer
For warranty service, please contact the dealer where you sell the company's
products. This warranty does not apply to the following situations, and the evaluation
of this operation is at the discretion of the manufacturer:
1.Problems caused by normal wear and tear or failure to operate according to the
enclosed user manual;
2. Products whose serial numbers have been removed or destroyed;
3. Products affected by negligence, accident and incorrect operation, maintenance
or storage;
4. Products modified without the explicit written permission of the manufacturer,
including (but not limited to) the use of unauthorized parts or accessories;
5. Products that are damaged by repairing any component without the explicit
consent of the manufacturer;
6. Products damaged due to circumstances beyond the control of the manufacturer
(such as earthquakes, floods, etc.)
7. Products repaired by anyone other than the manufacturer's seller.
8. The above warranty is the only warranty, it replaces any express warranty (if any),
which includes an implied warranty of suitability for a specific purpose;
9. These warranty periods should not exceed the express warranty period specified
in the warranty, and the remedies for breach of the implied warranty are limited to
repair or replacement of defective or problematic products in accordance with the
terms of the warranty.
10. The manufacturer does not assume any responsibility for any subsequent or
incidental
Please refer to the real object. In order to maintain product optimization and better
user experience, the manufacturer reserves the right to update the technology or
function to improve the product without informing the user.
- 10 - - 11 -