FRONT PANEL CONTROLS
ON/OFF ....................................Meter Lamp Switch
3000W/300W.............................Range Switch
PEAK/AVG................................Selection Switch
REAR PANEL CONNECTIONS
RF OUTPUT..............................SO-239 Connector
RF INPUT..................................SO-239 Connector
POWER CONNECTOR ...........2.5 mm coaxial type jack
INSTALLATION
. Connect the coax connector labeled RF INPUT to the transmitter
using PL-259 connectors. If using an antenna tuner, the PM-30
should be placed between the transmitter and antenna tuner.
2. Connect the coax connector labeled RF OUTPUT to the antenna
using a PL-259 connector. If using an antenna tuner, the RF
OUTPUT is connected to the antenna tuner input.
Note: Vectronics recommends using high quality coax cable for all
coax connections.
3. If a lighted meter is desired, a 9- 2Vdc power supply, such as the
AC- 2, must be connected to the power jack on the back of the unit.
This is a 2.5mm coaxial type jack with the center positive.
OPERATION
. Set the desired power range by using the push-button switch on the
front panel labeled POWER 3000W/300W. With the switch in the out
position, the 300W range is selected. When the switch is locked in,
the 3000W range is selected.