STANDARD DETECTOR MOUNTING 4” BASE VDOT-UB4
NOT TO BE USED FOR INSTALLATION PURPOSES.
Velocity reserves the right to make changes at any time without
notice in prices, colours, materials, components, equipment, speci-
cations and models and also to discontinue models.
Features
• UL Listed Base
• Compatible to Velocity’s UL Listed detectors
• Contains a locking screw for tamper protection
• 4 terminals to be used depending on detectors
• Mounts to 3-1/2” octagonal and 4” octagonal electrical
boxes
Description
VDOT-UB4 Standard Base is a 4 inch mounting base for Velocity’s
UL listed detectors that can be mounted to 3-1/2 inch and 4
inch octagonal electrical boxes. The base contains no electrical
circuit so that the base is used as a terminal block. The base is
supplied with 4 terminals that are used depending on the
detector heads. The 12 – 22 AWG eld wire can be connected
to the terminals. VDOT-UB4 contains a locking screw to avoid
unauthorized removal of detectors.
Dimensions
Page 1
Compatible Detector Models
Models Description
VDOT-PY Addressable Photoelectric Smoke Detector
VDOT-PYH Addressable Multisensory Detector
VDOT-H2 Addressable Heat Detector
VDOT-H2-H Addressable High-temp. Heat Detector
VDOT-DPH Addressable Dual Optical / Heat Detector
Distributed By
hp://www.velocitydetecon.com
GLT-299-6-6 Rev.0
Zeta Alarms Limited
72-78 Morfa Road, Swansea
SA1 2EN
Tel: +44 1792 455 175 FAX: +44 1792 455 176
All specicaons are subject to change without any noce.
For more informaon, contact with VELOCITY.
Wiring
VDOT-UB4 contains a locking screw to avoid unauthorized
removal of detectors.
Mounting
VDOT-UB4 is designed to be mounted to 3-1/2” and 4”
octagonal electrical boxes.
Specications
Specicaons VDOT-UB4
Operating Temperature -10°C to +83°C (14°F to 181.4°F)
Storage Temperature -20°C to +60°C (-4°F to 140°F)
Relative Humidity ≤ RH 95 % non-condensing
Environment Indoor, dry use only
Terminal AWG12-22
Dimensions φ104 mm x H 15 mm
Weight 65 g
Standard UL268 and UL521
Page 2
Installation Diagrams
Analog Addressable Wiring
When connected to analog addressable detectors such as VDOT-PY, VDOT-PYH, VDOT-H2, VDOT-DPH, etc.

Other Velocity Security Sensor manuals

Velocity VCode User manual

Velocity

Velocity VCode User manual

Velocity VDOT-H2 User manual

Velocity

Velocity VDOT-H2 User manual

Velocity VDOT-WGES24 Series User manual

Velocity

Velocity VDOT-WGES24 Series User manual

Velocity VL-W-M User manual

Velocity

Velocity VL-W-M User manual

Popular Security Sensor manuals by other brands

Inficon ELT3000 Translation of the original operating instructions

Inficon

Inficon ELT3000 Translation of the original operating instructions

SubSurface Instruments AquaTrac user manual

SubSurface Instruments

SubSurface Instruments AquaTrac user manual

Schaller Automation VN115/87plus EX Operation manual

Schaller Automation

Schaller Automation VN115/87plus EX Operation manual

Westfalia 961151 instruction manual

Westfalia

Westfalia 961151 instruction manual

Inovonics EE1261 installation instructions

Inovonics

Inovonics EE1261 installation instructions

Monitor Technologies DustAlarm ES Installation & operation

Monitor Technologies

Monitor Technologies DustAlarm ES Installation & operation

Nortech TD136 user manual

Nortech

Nortech TD136 user manual

Evolveo ACS PIRT manual

Evolveo

Evolveo ACS PIRT manual

LUXOMAT PD4-M-DALI/DSI-1C-FC Installation and operating instruction

LUXOMAT

LUXOMAT PD4-M-DALI/DSI-1C-FC Installation and operating instruction

Endress+Hauser NAR 300 operating instructions

Endress+Hauser

Endress+Hauser NAR 300 operating instructions

Schonstedt Loki series user guide

Schonstedt

Schonstedt Loki series user guide

Haneco SKYLUX Smart Control installation guide

Haneco

Haneco SKYLUX Smart Control installation guide

PCB Piezotronics TORKDISC 5302D-01A/012AC080AT Installation and operating manual

PCB Piezotronics

PCB Piezotronics TORKDISC 5302D-01A/012AC080AT Installation and operating manual

Interlogix TX-2413-03-1 Installation sheet

Interlogix

Interlogix TX-2413-03-1 Installation sheet

Safescan 155 Series manual

Safescan

Safescan 155 Series manual

Moldex Spectacle Kit 0098 User instructions

Moldex

Moldex Spectacle Kit 0098 User instructions

B.E.G. LUXOMAT net PD4-M-DAA4G Installation and operating instruction

B.E.G.

B.E.G. LUXOMAT net PD4-M-DAA4G Installation and operating instruction

Tecnosystemi Toolsplit TSCE-300 user manual

Tecnosystemi

Tecnosystemi Toolsplit TSCE-300 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.