Venmar 550VF1 User manual

INSTALLATION AND USER GUIDE
FOR RESIDENTIAL USE ONLY
REGISTER YOUR PRODUCT ONLINE AT: WWW.VENMAR.CA
24009 rev. A
!
AB0039
CENTRAL VACUUM POWER UNITS
!
MODELS SFDB-DK, SFDB-DL AND SFDB-DM
VENMAR VENTILATION ULC WWW.VENMAR.CA 1-877-896-1119
550VF1 / 650VF1 / 700VF1

2
SAVE THESE INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following:
GENERAL INFORMATION . . . . . . . . . 3
TOOL LISTING . . . . . . . . . . . . . . . . . . . . .3
W
ORKING WITH PLASTIC TUBING. . . . . . . . . . . . . 3
WALL INLET INSTALLATION . . . . . . . . 3
V800W CANSWEEP®
UNDER CABINET INSTALLATION . . . . 4-5
V800W CANSWEEP®
BASEBOARD WALL INSTALLATION . . . . 6
POWER UNIT INSTALLATION . . . . . . 7-9
LOCATING THE POWER UNIT . . . . . . . . . . . . . .7
CHANGING INTAKE LINE DIRECTION . . . . . . . . . . . 7
MOUNTING THE POWER UNIT . . . . . . . . . . . . . .8
FITTING MAIN LINE TO POWER UNIT . . . . . . . . . . .9
GROUNDING INSTRUCTIONS . . . . . . . 9
WIRING . . . . . . . . . . . . . . . . . . . . . . . .9
OPERATION AND MAINTENANCE . . .10-11
WHEN TO CHANGE BAG OR EMPTY DEBRIS PAIL . . . . 10
H
OW TO EMPTY DEBRIS PAIL
(650VF1 AND 700VF1 POWER UNITS ONLY) . . . . . 10
DISPOSABLE BAG REPLACEMENT
(550VF1 POWER UNIT ONLY) . . . . . . . . . . . . 10
PERMANENT FILTER
(650VF1 AND 700VF1 POWER UNITS ONLY) . . . . . 10
REMOVAL AND INSTALLATION OF PERMANENT FILTER
(650VF1 AND 700VF1 POWER UNITS ONLY) . . . . . 10
REMOVAL AND INSTALLATION OF HEPA FILTER
(700VF1 POWER UNIT ONLY) . . . . . . . . . . . . 11
MOTOR FOAM FILTER (ALL UNITS) . . . . . . . . . . . 11
TROUBLESHOOTING GUIDE. . . . . . . 12
SERVICE PARTS . . . . . . . . . . . . . 13
WARRANTY . . . . . . . . . . . . . . . . 14
TABLE OF CONTENTS
WARNING
To reduce the risk of fire, electric shock or injury:
1. Do not use on wet surfaces or outdoors.
2. Do not vacuum liquids or fine powders (such as drywall dust).
3. Do not use to pick up flammable or combustible liquids such
as gasoline or use in areas where they may be present.
4. Do not pick up anything that is burning or smoking, such as
cigarettes, matches, or hot ashes.
5. Do not allow to be used as a toy.Close attention is necessary
when used by or near children.
6. Use only as described in this manual. Use only
manufacturer's recommended attachments.
7. Keep hair, loose clothing, fingers and all parts of body away
from openings and moving parts.
8. Turn off all controls before unplugging.
9. Use extra care when cleaning on stairs.
10. Do not handle plug or appliance with wet hands.
11. Do not use with damaged cord or plug. If appliance is not
working as it should, if it has been dropped, damaged,
left outdoors, or dropped into water, return it to a Service
Center.
12.Keep your work area well lighted.
13.Connect to a properly grounded outlet only. See grounding
instructions shown on page 9.
14.When performing installation, servicing or cleaning the unit,
it is recommended to wear safety glasses and gloves.
15.When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at
his own expenses.
CAUTION
1. Do not put any object into openings. Do not use with any
opening blocked; keep free of dust, lint, hair and anything
that may reduce air flow.
2. Ensure air flows freely and exhausts unobstructed from top
or side outlet.
3. Do not use without filter (or filters, according to the model)
in place.
4. Do not use to blow leaves or debris.
5. Do not place any object on top of the unit.
6. Do not install the unit horizontally.
7. Do not use the pail as a wash bucket.
8. Do not use the pail as a stool.
9. Avoid picking up sharp objects.
10. This appliance is for use on a standard 120 VAC, dedicated
15-amp branch circuit. Some brands of house panel
breakers may be more sensitive to startup current than
others (for example, Square D brand). In the event where
nuisance tripping of the house panel breaker occurs*, we
recommend changing the breaker with an “HM” type of the
same AMP rating.
* after ensuring that the circuit is DEDICATED to the central
vacuum unit, meaning that there is no other electrical
device connected to the central vacuum unit circuit.
11. Do not unplug the unit by pulling on cord. To unplug, grasp
the plug, not the cord.
12.Store your vacuum cleaner indoors in a clean, dry area, and
away from extreme temperatures.
13.Any servicing other than that recommended in this manual
should be performed by an authorized service facility.
14.We recommend that your unit be inspected by a specialized
technician once a year.
!

3
TOOL LISTING
Depending on the installation, the use of the following tools
may be required:
Wire strippers, 1/4’’ and 1/2” drill bits, utility knife, putty knife,
2½’’ hole saw, keyhole saw, hammer, cold chisel, level,
flashlight, drill, electrical tape, Phillips no. 2 screwdriver,
wrench, hacksaw, tape measure, safety glasses.
Power tools are recommended to make the installation proceed
quickly. A mask and gloves should be worn when cutting
ducting and using glue.
WORKING WITH PLASTIC TUBING
CUTTING TUBING
Measure the length of tube needed. Allow 5/8” of tubing for
inserting into fittings and 1½” for placing into flexible tubing.
Cut the plastic tubing with a hacksaw, ensuring that the cut
is exactly square. Use wire cutters or tin snips to cut flexible
tubing, 8” lengths of flexible tubing should not be cut.
Use a small knife or steel wool to remove any burrs from the
inside of the tube.
Use a file to slightly bevel the outside of the tube so that it will
easily slide into the fitting. Use steel wool or a light grained
sandpaper to buff the surface of the tube which will be glued.
MAKING A JOINT
Insert the tube into the fitting,
aligning both parts as they will be
installed. Mark the tube and the
fitting to quickly realign the joint.
Apply cement in an inch-wide
band to the outside of the tube.
Insert the tube into the fitting with
the alignment marks a quarter
turn apart, and then quickly push
and turn the fitting to align the
marks and spread the cement.
Allow 1 minute for the joint to dry.
CEMENTING FLEXIBLE
TUBING
Ensure the ends of the flexible tubing are even. When joining
flexible tubing to plastic tubing or to an inlet mounting plate,
apply cement to both the inside of the flexible tubing and the
outside of the plastic tubing or mounting plate tubing ring.Twist
both pieces while joining them to evenly spread the glue. Allow
5 minutes for the cement to set in flexible tubing.
SECURE WIRE TO
TUBING
The low-voltage power wiring is
run along with the tubing. Use
electrical tape to secure the
wire to the tubing. Tape the wire
approximately every 12" to 18".
MAKING THE WALL INLET CUTOUT
The wall inlet should be located 18” on-center from the floor
and directly in line with the attic or basement inlet tubing hole
previously drilled in the wall plate or header. The wall inlet
cutout must be exactly 37∕8” high by 27∕8” wide.
ATTACHING THE INLET MOUNTING PLATE
(V144)
Reach through the inlet hole and locate the inlet tubing. Pull
the flexible tubing through the inlet hole and remove the
low-voltage wiring from inside the tube.
Remove the nail flange
from the inlet mounting
plate (see illustration at
right). Apply cement to
both the inside of the
flexible tubing and to the
outside of the mounting
plate’s tube ring. Insert
the mounting plate’s
tube ring in the flexible
tubing and twisting the
pieces as you join them
to spread the cement, and align the mounting plate in a vertical
position.
Now, strip the ends of the two low-voltage wires, and then
connect the wires to the screw terminals on the back of the
inlet cover. When the wiring is complete, assemble the inlet
cover to the tube guard and mounting plate.
COMPLETING
THE INLET
ASSEMBLY
Once you have attached
the mounting plate to the
flexible tubing, pull the
low-voltage wire through
the top wiring hole in the
mounting plate.
INSTALLING
THE INLET (V111)
Place the inlet into the
wall cutout (the inlet
cover remains on the
outside). Hold the inlet
in place and gradually
tighten down each screw
a little bit at a time.
GENERAL INFORMATION WALL INLET INSTALLATION
AO0010
AO0011
INLET MOUNTING
PLATE
AE0024A
AO0045
AR0040

4
Template
Align the template
(cut from this
instruction sheet)
onto the kick plate to
the desired location,
and trace the outline
of the area.
Mark Center
Cut out the desired
opening and
discretely mark the
center of the
opening on the floor.
Drill a small
reference hole
along the
center line
behind the
kick plate
through the
subfloor.
Locate the
reference hole from
beneath the
subfloor. Cut a
4” x 4” access hole
on your chosen
position along the
center line under
the kick space.
Cabinet Space
Kick Space
Kick Plate
Opening
Reference
Hole
4" x 4" Access
Hole
V800W CANSWEEP®
TEMPLATE
6¾"
2⅜"
If by any chance the opening was cut too big,
a trim plate (part number V801W) is available
to provide a perfect cover.
Trim plate
V800W CANSWEEP® UNDER CABINET INSTALLATION

5
Solvent weld a coupling
to a piece of 2” central
vacuum pipe, long enough
to reach the 4” x 4” access
hole from the opening on
the kick plate (Fig. A).
Friction fit the other end
of the coupling to the
CanSweep®until secure.
Do not glue, friction fit only
(Fig. B).
Insert the
CanSweep®/pipe
into the opening on
the kick plate.
Use a 90° sweep
elbow fitting to
determine a cut
mark on the other
end of the pipe.
Then cut the pipe
at the mark.
Slide the
low voltage wires
into the
CanSweep®clips
as shown to
complete the wiring
connections.
Slide the
CanSweep®/pipe
and low voltage
wires into the
opening on
the kick plate. Glue
both ends of the
elbow to the piping
system, and then
secure the
CanSweep®to the kick plate with the 2 supplied screws.
Fig. A
Fig. B
Screws
Glue elbow
to pipe
V800W CANSWEEP® UNDER CABINET INSTALLATION (CONT'D)

6
Template
Choose a desired
position on the baseboard
between two studs.
Place the template (cut
from this instruction sheet)
on the position, and trace
the outline of the area.
2" x 4" Bottom Plate
Trim the opening on
the baseboard and
through the drywall
until reaching the
2" x 4" bottom wall
plate.
Against the edge of the
2" x 4" bottom plate, mark the
center of the opening.
Reference
Hole
2" x 4"
Bottom Plate
Make piping
connections as
required and
ready the short
90° elbow in position
behind the CanSweep®.
Make sure that the opening of the elbow will securely
attach onto the spigot on the back of the CanSweep®
when it is time for connection.
Slide the
CanSweep®and
low voltage wires
into the opening
on the
baseboard.
Friction fit the
CanSweep®
spigot into the elbow. Secure the CanSweep®to the
baseboard with the 2 supplied screws.
Do not glue
CanSweep®to
the elbow.
Attach wires
Mark Center
Drill a small reference hole
at the mark through the subfloor to below.
Locate the reference hole from below
and measure back 1
7/8”. Use a 2” hole saw
to remove the 2"x4" bottom plate
section behind the opening.
Reference Hole 1⅞"
Slide the low volt wires into the CanSweep®clips
as shown to complete the wiring connections.
V800W CANSWEEP® BASEBOARD WALL INSTALLATION

7
LOCATING THE POWER UNIT
• Locate the power unit away from the general living area in
an accessible location for cleaning and maintenance.
• Locatethepowerunitwithin6feetofagroundedelectricaloutlet.
The power unit requires a 120 VAC power source, dedicated
15-amp branch circuit.
• Do not locate the power unit close to a source of extreme
heat (i.e.: water heater) or in an area with a high ambient
temperature (i.e.: attic, furnace room).
• If the power unit is located in a closet or a small utility
room, make sure the area is well-ventilated (e.g.: with door
louvers).
CHANGING INTAKE LINE DIRECTION
The intake line connects to the right side of the unit. However,
it is possible to change this configuration; to connect the intake
line to the left side of the unit, follow these steps:
Remove debris pail from power unit by releasing both latches
on sides of the unit, pulling them out and then pushing up.
Detach the pail from unit.
550VF1 only: Grasp
the edges of the bag
collar and pull down;
the bag will slide off
easily. Do not pull on
the bag. Set the bag
aside.
550VF1 only: Using
a Phillips screwdriver
no. 2, remove the
screw tightening the
bag adapter and
intake elbow junction.
Disassemble the
bag adapter from the
intake elbow and set
aside with its screw
and nut.
Allunits:Disassemble
the intake elbow from
the back of the unit
using a 3/8” socket to
remove both retaining
nuts and screws.
All units: Flip the
intake elbow 180°,
then reassemble it to
the unit, taking care to
keep its gasket at its
original position.
NOTE: Ensure the
gasket is not folded in
order to prevent lack of suction, and noise.
550VF1 only:
Reassemble the bag
adapter to the intake
elbow. Align triangle
with small inclined
stud, then tighten
the junction using
the screw and nut
previously removed in
.
550VF1 only: Put the
bag back in place by
grasping the edges of
its collar and insert
over bag adapter. Be
careful not to tear the
bag. Ensure the collar
is positioned between
the taper ring and the
bag stopper on the
bag adapter.
All units: Put the pail back in place.
POWER UNIT INSTALLATION
AD0076
AO0078
550VF1 ONLY
AD0075
550VF1 ONLY
AD0077
AD0078
550VF1 ONLY
AO0080
550VF1 ONLY TAPER RING
BAG STOPPER
WARNING
!
Do not install outdoors. Before being hung, rest the
unit on a leveled surface to prevent the unit to fall
down. When performing installation, servicing or
cleaning the unit, it is recommended to wear safety
glasses and gloves.

8
MOUNTING THE POWER UNIT
Carefully remove debris pail from power unit. Make sure
bag is properly installed in power unit (550VF1 unit only).
Remove the installation kit and securely reinstall debris pail.
Refer to illustration below to maintain minimum walls and
floor clearance dimensions.
Position and install the wall mounting bracket with the
provided screws. Refer to illustration in the right column for
proper mounting dimensions.
Use the provided mounting screws to secure the mounting
bracket on the wall through upper and lower mounting
holes.
Hang power unit onto wall mounting bracket. Ensure
the back brackets of the power unit are engaged with
corresponding wall bracket fingers (or top fingers and lower
tab for 550VF1 model; see figure below). Pull the power unit
down to secure.
POWER UNIT INSTALLATION (CONT'D)
C
L
3/4” TYP.
32 7/8”
1” TYP.
45¼”
MIN.
HEIGHT
18 ¹/8”18 ¹/8”
UPPER
MOUNTING
HOLES
LOWER
MOUNTING
HOLES
AD0079A
CAUTION
Ensure to screw the wall mounting bracket directly
to a wall stud for a solid installation.
18” minimum
above floor
12” minimum
from ceiling
12”
minimum
TOP VIEW
FRONT VIEW
MINIMUM CLEARANCE DIMENSIONS
12”
minimum
AD0039A
AD0074
650VF1 AND 700VF1
550VF1

9
FITTING MAIN LINE TO POWER UNIT
Run house vacuum line up to the elbow behind the power
unit. Insert the end of the line in the elbow opening and
secure house vacuum line by hand tightening the screw
and nut provided (see illustration below) DO NOT GLUE.
Assemble exhaust tubing to exhaust outlet on top or top
side of the unit, according to the power unit model. DO NOT
GLUE.
NOTE FOR 700VF1 UNIT ONLY
If desired, the
coupling or elbow
used to connect
the exhaust line to
the top of the unit
may be secured
using two 5/8”
included screws.
See illustration at
right.
NOTE: Using flexible tubing will ease future top cap removal.
Make sure all tubing connections are air tight.
The exhaust should not be vented into a wall, ceiling or
concealed space in the house. It is recommended to vent
the vacuum exhaust air to the outdoors. Exterior vented
exhaust line should end using Model V145 wall cap.
NOTE: For optimal indoor air quality, exhausting the
power unit to the outdoors is recommended but is
not required, especially for 700VF1 unit which is
equipped with an exhaust HEPA filter.
Grounding Instructions – This appliance must be grounded.
If it should malfunction or break down, grounding provides a
path of least resistance for electric current, to reduce the risk
of electric shock.This appliance is equipped with a cord having
an equipment-grounding conductor and grounding plug. The
plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and
ordinances.
WIRING
This appliance is for use on a standard 120 VAC, dedicated
15-amp branch circuit with a NEMA 5-15R receptacle. Make
sure that the power unit is connected to an outlet and has a
grounding attachment plug that looks like the plug shown in
illustration below. No adapter should be used with this power
unit.
NOTE: Inlet leads to be connected to power unit low voltage
tabs using crimp connectors (included in parts bag)
and low voltage harness.
POWER UNIT INSTALLATION
(CONT'D)GROUNDING
INSTRUCTIONS
AJ0001
INTAKE LINE
SCREW AND
NUT FROM
PARTS BAG
INTAKE LINE TYPICAL CONNECTION
TO POWER UNIT
WARNING
!
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service person
if you are in doubt as to whether the outlet is
properly grounded. Do not modify the plug provided
with the appliance – if it will not fit the outlet, have
a proper outlet installed by a qualified electrician.
AJ0003
AE0044 INLET
CRIMP
CONNECTORS TO
BE CONNECTED
IN LOW VOLTAGE
TABS
INLET INLET
TO
OTHER
INLETS
MODEL V133 (22/2)
LOW VOLTAGE WIRE
INLET LEADS
GROUNDED OUTLETS
GROUNDING PIN

10
Open the wall inlet cover and insert the end of the hose into the
inlet to turn on the vacuum.
For non-switched hoses, inserting the hose automatically turns
on the power unit; removing the hose shuts off the power unit.
Some hoses have switches which can be used to activate
power unit. The ON/OFF switch located on the power unit
needs to be kept in the OFF position.
As you vacuum, dirt and dust are carried to the power unit
where they remain in a bag or in the debris pail (according to
the power unit model).
Use the cleaning tools as you would for any other vacuum
cleaner. Avoid picking up very large debris or lengthy as these
kinds of objects may become lodged in the hose or tubing.
WHEN TO CHANGE BAG* OR EMPTY
DEBRIS PAIL
With a 6 U.S. gallons (22.7 liters) capacity, under normal
conditions the bag/debris pail requires changing/emptying
approximately twice a year. If the bag/debris pail is full, you will
notice a reduced suction from the system. Unless this loss of
suction is caused by a blockage in the system, changing the
bag or emptying the debris pail will solve the problem.
NOTE: Even if not filled to capacity, if the bag seems tightly
stretched when removing the debris pail, changing
the bag will prevent it from tearing.
* Only 550VF1 unit is equipped with a disposable bag (391C).
HOWTO EMPTYDEBRIS PAIL(650VF1
AND 700VF1 POWER UNITS ONLY)
To empty the debris pail, release both latches on sides of the
unit by pulling out and then pushing up. Holding the pail by the
latches, lower it from unit. Carry pail to trash receptacle and
dispose of debris. Put the pail back in its place.
DISPOSABLE BAG REPLACEMENT
(550VF1 POWER UNIT ONLY)
To remove the disposable bag, release both latches on
sides of the unit by pulling out and then pushing up. Remove
the pail from unit. Grasp the edges of the bag collar and pull
down. The bag will slide off easily. Do not pull on the bag.
Unfold the new bag.
Grasp collar where indicated on the new bag and insert over
bag adapter. Be careful not to tear the bag. Ensure the collar
is positioned between the taper ring and the bag stopper on
the bag adapter (see illustration below). Put the pail back in
its place.
PERMANENT FILTER
(650VF1 AND 700VF1 POWER UNITS
ONLY)
This filter protects the motor and stops small particles from
escaping to the outside of the power unit wihout the need to
replace it. The filter cleans itself by moving up when the power
unit starts, and dropping down when the unit is turned off.
Under normal use, there is no need to maintenance this filter.
It is possible to remove it to inspect the motor foam filter, or
to replace it if ever it has been damaged (by sharp debris, for
example).
REMOVAL AND INSTALLATION OF
PERMANENT FILTER (650VF1 AND
700VF1 POWER UNITS ONLY)
Remove the pail from unit.
To remove the permanent
filter, use pull tab (A)
located on edge of filter to
pull and loosen filter from
inlet chamber wall. Squeeze
from both sides of the filter
to the center of the housing.
Then, carefully remove it
from the unit.
Squeeze the filter in order
to move it past the inlet
opening (B) Let the filter
bear against the unit wall
by releasing the pressure.
Make sure to place the rigid
ring in its groove to ensure
proper sealing.
NOTE: Make sure the filter is
installed so that the pull
tab (A) is accessible
for future filter removal.
OPERATION AND MAINTENANCE
AO0081
TAPER RING
BAG STOPPER
AA0005
A
AD0084
A
AD0085
B
CAUTION
Be sure to reinstall filter properly. Appropriate
location is critical to insure proper protection of
the motor.

11
OPERATION AND MAINTENANCE (CONT'D)
CAUTION
Operating the power unit without the motor foam
filter will void the warranty.
AD0086
WARNING
!
Risk of warm surfaces and sharp edges. It is
recommended to wear safety gloves while handling
this HEPA filter.
4 X
AR0053
AB
REMOVAL AND INSTALLATION
OF HEPA FILTER
(700VF1 POWER UNIT ONLY)
NOTE: This is a disposable HEPA filter; do not attempt to
wash it since this will damage it.
This HEPA filter should be replaced every 5 years. Proceed as
follow:
If installed, detach the exhaust line from the top of the unit.
Disassemble upper part from lower part top cap assembly
by pushing on the 4 retaining tabs (one by one) located on
the lower part and pulling on upper part to disengage it.
NOTE: A small flat blade screwdriver can also be used to
pry on the 4 retaining tabs, as shown in illustration A
at the bottom of the page.
Discard the used filter and replace with a new one (part
no. S10941416). Be sure to install it with the gasket on top as
shown in illustration B (at the botton of the page), then snap
in place the upper part of the top cap. If need be, reconnect
the exhaust line to the top cap.
MOTOR FOAM FILTER
(ALL UNITS)
A motor foam safety filter, located at the top of the vacuum
chamber provides protection against dirt being pulled into
the motor if the disposable bag or permanent filter should
accidentally be torn. This filter should be checked and cleaned
if necessary when replacement bag is installed (550VF1
unit only), or when permanent filter is removed (650VF1 and
700VF1 units only). Simply brush filter clean. If the filter is
excessively soiled, hand wash in a water and mild detergent
solution, rinse and let it dry completely on a flat surface before
reinstalling.
REMOVING MOTOR
FOAM FILTER
Remove the debris pail
and disposable bag or
permanent filter. Lift the
center of the wire retaining
the motor foam filter and
slide the filter out of its
location.
REINSTALLING
MOTOR FOAM
FILTER
To reinstall the motor foam
filter, reverse the steps
described above.

12
TROUBLESHOOTING GUIDE
PROBLEMS POSSIBLE CAUSES POSSIBLE REMEDY
1. Loss or decrease of
suction occurs. • Debris pail or disposable bag is completely full.
• Debris pail gasket damaged or missing.
• Obstruction in the hose. A blockage in the hose
can be determined by inserting the hose into
any wall inlet and, while power unit is running,
check each additional inlet for normal suction
by holding the palm of your hand over the
open inlet. If normal suction is felt at all other
inlets, insert the hose into a second inlet. If the
blockage still exists it is located in the hose.
However, if the blockage does not occur when
the hose is changed, the blockage is probably
located in the tubing system leading to the
original inlet.
• Obstruction in the tubing system inside the
walls.
• Permanent filter or disposable bag torn.
• Wall inlet cover not properly sealed.
• Exhaust tubing or vent clogged.
• Change the disposable bag or empty debris pail
as described on page 10.
• Replace the debris pail gasket.
• Disconnect the hose from the wall inlet and
insert a blunt instrument into the hose —
slightly smaller in diameter — such as a flexible
garden hose. Push the garden hose through the
cleaning system hose until the obstruction has
been cleared.
• Insert hose end into any inlet to make power unit
running, then place the palm of your hand over
the opposite end of the hose.When you can feel
the suction increase, hold your hand over the
hose end for a few seconds and then quickly
remove your hand. This procedure repeated
several times should clear the obstruction. If the
blockage is not cleared, contact your nearest
Service Center.
• Clean the interior or the unit and install a new
permanent filter (or disposable bag).
• Check all wall inlet covers to be sure they are
closed and sealed tightly.
• Inspect and remove any blockages.
2. Power unit does
not start, or stops
suddenly.
• Defective inlet. Check other wall inlets.
• Power unit internal circuit breaker has been
activated (the reset button is popped up).
• Blown fuse or tripped circuit breaker on house
electrical panel.
• Defective hose.
• Power unit overcurrent protector has been
activated.
3. Power unit runs
continuously when
the hose is removed.
• The unit power switch is in ON position.
• An electrical short has occurred somewhere in
the system.
• Set the unit power switch to OFF position.
• Perform a complete check of all wall inlets and
power unit low voltage control lead connections.
Contact your authorized Service Center.
• Replace defective wall inlet.
• Push on the circuit
breaker reset
button located on
the left side of
the power unit. If
this button pops
up again, contact
your authorized
Service Center.
• Replace fuse or reset circuit breaker on house
electrical panel.Ensure the circuit is DEDICATED
to the central vacuum unit, meaning that there
is no other electrical device connected to the
central vacuum unit circuit.
• Some brands of house panel breakers may be
more sensitive to startup current than others (for
example, Square D brand). Correct the situation
by changing the breaker with an “HM” type of
the same AMP rating.
• Replace hose as required.
• Unplug the power unit, wait at least 15 minutes
and plug the power unit back in.
AC0003
POWER SWITCH
RESET
BUTTON

13
AL0020
SERVICE PARTS
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working
condition, you must use Venmar Ventilation ULC genuine
replacement parts only. Venmar Ventilation ULC genuine
replacement parts are specially designed for each unit
and are manufactured to comply with all the applicable
certification standards and maintain a high standard of
safety. Any third party replacement part used may cause
serious damage and drastically reduce the performance
level of your unit, which will result in premature failing.
Venmar Ventilation ULC also recommends to contact a
Venmar Ventilation ULC certified service depot for all
replacement parts and repairs.
4
11
7
13
KEY NO.PART NO.DESCRIPTION 550VF1 650VF1 700VF1
1S10941410 700VF1 TOP CAP ASSEMBLY (INCLUDING ITEM 5) (UPPER PART)1
S10941412 550VF1 AND 650VF1 TOP CAP ASSEMBLY 11
2 S10941416 700VF1 EXHAUST HEPA FILTER 1
3 S10941414 700VF1 TOP CAP ASSEMBLY (LOWER PART)1
4 66369 MOTOR FOAM FILTER WITH FASTENER 11 1
5 S10941400 GASKET 11 3
6 S10941415 PERMANENT FILTER 11
7 S99670648 DEBRIS PAIL (INCLUDING KEY NO. 8) 1 1 1
8 S10941199 LATCH AND SCREWS 22 2
9 S10941404 LATCH KEEPER WITH SCREWS 22 2
10 S10941405 BAG ADAPTER WITH NUT AND SCREW 1
11 S10941406 INTAKE ELBOW WITH GASKET, SCREWS, AND NUTS 11 1
12 S99670650 EXHAUST PORT WITH GASKET AND SCREWS 11
13 S30390555 UNIT SUPPORT BRACKET 11 1
* 391C DISPOSABLE BAG (SET OF 3) 1
NOTE: Order service parts by “Part No.” — not by “Key No.”
5
6
8
1
3
700VF1 UNIT
550VF1 AND 650VF1 UNITS
9
10
1
2
12
* ITEM NOT SHOWN

14
WARRANTY
VENMAR MODELS 550VF1, 650VF1 AND 700VF1
VENMAR VENTILATION ULC
CENTRAL VACUUM POWER UNIT
LIMITED WARRANTY
Venmar Ventilation ULC warrants to the original consumer purchaser that its central vacuum power unit will be free from defects in materials
and workmanship for five (5) years for 550VF1 units, eight (8) years for 650VF1 units and ten (10) years for 700VF1 units. This warranty
covers the parts and labor in an authorized service center for the first three (3) years of the warranty for 550VF1 units, the first five (5) years of
the warranty for 650VF1 units, the first six (6) years of the warranty for 700VF1 units. After these time periods, the parts only will be covered
under this warranty. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During these time periods, Venmar Ventilation ULC will, at its option, repair or replace the power unit or part without charge, which is found
to be defective under normal use and service.THIS WARRANTY DOES NOT APPLY TO THE INSTALLATION OR THE PARTS USED IN THE
INSTALLED TUBING SYSTEM. All central vacuum hoses, electric or air-driven brushes, filters, attachments and accessories are warranted
for one (1) year from the original purchase date with the exception to consumables such as light bulbs and belts.We invite you to register your
product on line at www.venmar.ca. Venmar Ventilation ULC reserves the right to limit this warranty if the product is not registered.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence,
accident, improper maintenance or repair (other than by Venmar Ventilation ULC or an authorized representative), faulty installation or
installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the period as specified for the express warranty.
VENMAR VENTILATION ULC’S OBLIGATION TO REPAIR OR REPLACE, AT VENMAR VENTILATION ULC’S OPTION, SHALL BE THE
PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENMAR VENTILATION ULC SHALL NOT BE LIABLE
FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR
PERFORMANCE. Please do not return your unit to place of purchase. Please visit www.venmar.ca for your closest service center. You may
also call 1-877-896-1119 for the name of an authorized representative in your area. This warranty supersedes all prior warranties.
Warranty service is to be completed by an authorized Service Center designated by Venmar Ventilation ULC. Where applicable, in home
service will be made available only in areas where a contracted service provider offers service during the first three (3) years of the warranty
for 550VF1 units, the first five (5) years of the warranty for 650VF1 units and the first six (6) years of the warranty for 700VF1 units. If in home
service is not available, the product will be repaired or replaced, at Venmar Ventilation ULC’s discretion, by the nearest authorized service
provider. The unit removal and reinstallation works are under the customer responsibility, and Venmar Ventilation ULC cannot be charged for
them.
To qualify for warranty service, you must notify Venmar Ventilation ULC at the address or telephone number stated below. We will then forward
you the authorized service depot in your area.You will be required to present evidence of the original purchase date.
Date of Installation Builder or Installer
Model Number and Product Description
IF YOU NEED ASSISTANCE OR SERVICE
For the location of your nearest Venmar Ventilation ULC dealer, dial toll free: 1-877-896-1119
Please be prepared to provide: Product model number • Date and proof of purchase • The nature of the difficulty
Venmar Ventilation ULC
Product specifications subject to change without notice. Printed in Canada.
This manual suits for next models
2
Table of contents
Popular Portable Generator manuals by other brands

Yamaha
Yamaha FB-01/U owner's manual

Generac Power Systems
Generac Power Systems 0061520 owner's manual

Honeywell
Honeywell HW6200 - Portable Generator NOT owner's manual

Husky
Husky HU40500 Series Operator's manual

Westerbeke
Westerbeke EDT Series Operator's manual

Master Quality Power
Master Quality Power XFG2000 owner's manual