Vent-Axia SUNB3000BL User manual

INSTRUCTION MANUAL
Model:- SUNB3000BL
CAUTION
Read Instructions Carefully
For Safe Installation and
Heater Operation
CONTENTS
MAIN TECHNICAL DATA
INSTALLATION CAUTION
WALL/CEILING INSTALLATION
MAINTENANCE
STORAGE AND DISPOSAL
THANK YOU FOR PURCHASING
Thank you for purchasing this quality Heater. To ensure correct function and safety, please read all
instructions before using the product and keep all instructions for future reference.
WARNING
When using electrical appliances, basic safety precautions should always be followed to
reduce the risk of fire, electrical shock and personal injury. This Heater must be permanently installed and
hard wired by a qualified electrician, Do not extend the supplied cord.

MAIN TECHNICAL DATA
BEFORE INSTALLATION CAUTION
IMPORTANT
HEATER INSTALLATION AND ELECTRICAL CONNECTION MUST
BE DONE BY A LICENSED ELECTRICIAN.
THE LAMP IS NOT A REPLACEABLE ITEM
Theinfraredheaterisdesignedforsafeoperation.Nevertheless,installation,maintenanceandoperationofthe
heatercanbedangerous.Observingthefollowingprocedureswillreducetheriskoffire,electricshock,injuryto
personsandkeepinstallationtimetoaminimum.Savetheseinstructionsforfutureuse.
THESEINSTRUCTIONSSHOULDBEREADCAREFULLYANDRETAINEDFORFUTUREREFERENCE.
Wecannotbeliableforanydamagescausedbyfailuretoobservetheseinstructions.
IMPORTANT:
1. Read all instructions before using this heater.
2. Remove the unit from its packaging and check to make sure it
is in good condition before using.
3. Do not let children play with packaging.
4. Check the household voltage to ensure it matches the heater’s
rated specification.
5. Check the power cord carefully before using to ensure there is
no damage. DO NOT EXTEND.
6. Before working on the electrics, be sure to turn off the power.
When energising the unit, be sure your hands are dry to
prevent electric shock.
SUNB3000BL
IP Rating: IP54
Rated Voltage: 220 - 240V ~ 50Hz
Heater Power Input: 3000W
Dimensions:
Weight: 4.2 kg

7. This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, such as
furniture, pillows, bedding, papers, clothes, and curtains at
least 3 feet (1 m) from the front of the heater and keep them
away from the sides and rear.
8. Do not use near or in the immediate vicinity of a bath or
swimming pool or any wet areas.
9. To protect against electric shock, do not immerse cord in water
or any other liquids.
10. Do not insert or allow foreign objects to enter any ventilation
openings, as this may cause an electric shock, fire or damage
to the heater.
11. Disconnect the heater when not in use, if applicable.
12. Connect to properly grounded outlets only.
13. Always Permanently Hard wire the heater using appropriate
rigid metallic, flexible or liquid tight conduit suitable for an
IP54 rated installation. Never extend the supplied cord.
14. Do not allow cord to overhang the counter top where it can be
easily pulled by children.
15. Do not put fingers or foreign objects into the grille while in
operation.
16. Do not leave the appliance unattended when in use.
17. No liability can be accepted for any damage caused by non-
compliance with these instructions or any other improper use
or mishandling.
18. This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities
or lack of experience and knowledge unless they have been
given supervision or instruction concerning the use of the
appliance by a person responsible for their safety. Children
and vulnerable people should be supervised to ensure they do
not play with the appliance.
19. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.

20. Do not operate any heater with a damaged cord or after the
heater malfunctions, has been dropped or damaged in any
manner. Disconnect power at service panel and have heater
inspected by a reputable electrician before reusing. If the
supply cord is damaged in any way, it must be replaced by the
manufacturer or its service agent or a similarly qualified person
in order to avoid a hazard.
21. Do not run cord under carpet. Do not cover cord with throw
rugs, runners, or similar coverings. Do not route cord under
furniture or appliances. Arrange cord away from traffic area
and where it will not be tripped over.
22. To disconnect heater, turn controls to off, then disconnect from
the supply.
23. To prevent overheating of this appliance, keep the air inlets
and outlets clean and free of anything that may cause
blockage. Check all inlets and outlets from time to time to
ensure it is clear of any dirt or dust accumulation. DO NOT
COVER.
24. Do not use it in areas where gasoline, paint, or flammable
liquids are used or stored.
25. Parts of the heater may exceed 200Ԩ, contact with the heating
tube, reflector, or metal parts near the heating tube, may
cause severe burns. To avoid burns, do not let bare skin touch
hot surfaces.
26. NEVER place hands under the heating elements. ALWAYS
allow heating element to cool at least 10 minutes before
touching the heating tube or adjacent parts.
27. This product contains recyclable materials. Do not dispose
this product as unsorted municipal waste. Please contact your
local municipality for the nearest collection point.
28. The fireguard of this heater is intended to prevent direct
access to heating elements and must be in place when the
heater is in use.
29. The heater guard does not give full protection for young
children and infirm persons.

WARNING
BEFORE INSTALLING THE HEATER, MAKE SURE YOU HAVE TURNED OFF THE MAIN ELECTRICITY SUPPLY.
DO NOT TURN IT BACK ON UNTIL THE HEATER IS FULLY INSTALLED AND READY TO USE.
ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A LICENSED ELECTRICIAN IN ACCORDANCE WITH THE
LATEST WIRING REGULATIONS
INSTALLATION
A wall mounting brackets provided with the
heater which has been specifically designed
to allow this product to be fitted to a ceiling
or wall. Before drilling, ensure the wall or
ceiling are solid and that there are no
hidden water pipes or electric wires. The
heater must be installed no less than 0.5m
from side walls and no less than 1.8m off
the floor.
ATTENTION! The appliance must
be installed on a solid surface like
concrete, wood or metal etc.
Important: Ensure that the supply
cables are well mounted and that
they do not come into contact with
the reflector of the heater or that it
does not trail into heated areas.
The supply cable can be fixed to
the metal mounting bracket
behind the heater with plastic zip ties.
1. This heater must be permanently installed and hard wired by a qualified electrician.
DO NOT EXTEND THE CORD PROVIDED OR USE EXTENSION LEADS.
2. Always disconnect the heater from the electricity supply and allow it to cool before
installation.
3. For ceiling mounting, the lowest part of the heater must be located at or above a minimum
height of 1.8m from ground level, so that the heater cannot be touched when in operation.
4. For ceiling mounting, there must be a 1.8m distance from your appliance to the ground.
5. When installed to the ceiling, there must be a distance of 0.5m between corners and the
appliance.
6. The distance of your appliance from any objects or persons is to be min 1m.
7. The distance from the front side of the heater to materials such as wood, cloth etc., must be
min 1m.
8. When mounting to a ceiling, do not position the heater at an angle more than 90 degrees.

9. The supply cable must be at the lower end of the heater if it is installed at an angle.
10. Keep the supply cord away from the body of the heater as it will get hot during use.
11. Do not install the heater on a flammable surface.
12. Observe the minimum safe distance between the heater body and the flammable surfaces
when mounted.
13. The heater should always have a minimum clearance of 0.5m from a ceiling and adjacent
wall.
14. If the heater is to be used outside, The installing electrician will need to provide the
appropriate rigid metallic, flexible or liquid tight conduit suitable to maintain an IP54
installation.
15. Before drilling ensure that there are no wires or water pipes in the area where the heater is
to be installed.
16. The heater must be installed on the mounting brackets provided.
17. Fasten the brackets securely to the mounting surface and the backside of the heater using
the nuts and screws supplied.
18. Fasten the heater securely on the brackets using the nuts and bolts supplied.
19. The brackets can be used to adjust the direction of the heater, adjust the heater angle by
loosening the two bolts on the wall mounting bracket, and tighten the bolts again when the
desired angle is reached.
20. For bathrooms installation/s - the heater is to be installed so that switches and other
controls cannot be touched by a person in the bath or shower.
WIRING THE HEATER
All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of
your country and MUST be installed by a suitably qualified Electrician. The heater should be
provided with a local isolator switch capable of disconnecting all poles, having a contact separation
of at least 3mm.
WARNING: THE HEATER AND ANCILLARY CONTROL EQUIPMENT
MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE
INSTALLATION / OR MAINTENANCE.
IMPORTANT:- THIS HEATER MUST BE EARTHED
Connecting the power supply cable to the mains (220V-240V ~ AC)
220 V-240 V~ +10 % -10 % 50Hz Single phase power supply. Connect the power supply cable to
the mains as follows: -
Neutral (N) = Blue wire – Live (L)= Brown wire – Earth( ) = Green and yellow wire.
The wires must be connected in a suitable electrical connection box for the installation and must
comply with the applicable standards.
DO NOT EXTEND CORD.
FUNCTION & OPERATION
1. PRESSthepowerbuttonontherighthandsideoftheheaterON.TheheaterwillturnON
2. PRESSthepowerbuttonontherighthandsideoftheheaterOFF.TheheaterwillturnOFF.

EILING
INSTA
MAINTENANCE CAUTIONS
WARNING
BEFORE REPAIRING THE HEATER, MAKE SURE YOU HAVE TURNED OFF THE MAIN ELECTRICITY SUPPLY.
Caution:
When the appliance is not operated for a long period of time, cleaning or maintenance is conducted or when
the location of the heater is changed, the heater should be turned to OFF and disconnect from the electrical
supply. Periodic inspection and removal of dirt and contaminants will ensure that equipment can be
operated safely.
1. Make sure the heater is always switched off before cleaning.
2. Check the Reflector and IR-Filament for dirt, dust or contaminants at least once a month. If
necessary, apply cleaning and maintenance process.
3. The number of checks may be increased considering the amount of the dust in the environment.
4. Check the deformation of the Reflector, Wire and Frame visually while cleaning the appliance. In
case of deformation, consult your technical service.
5. Check the Power Cord and installation visually while cleaning the appliance. In case of deformation,
consult your technical service.
6. Never install the heater under extreme hot environments.
WALL / CEILING INSTALLATION

CLEANING, STORAGE AND DISPOSAL
Regular and careful cleaning helps your infrared heater operate efficiently for many trouble-free years. To
clean your heater, follow steps below:
1. Disconnect the power supply to the heater for your safety before cleaning your appliance.
2. Make sure the heater is cool before continuing.
3. To keep the heater clean, the outer shell maybe cleaned with a soft, damp cloth. You may use a mild
detergent if necessary. After cleaning, dry the unit with a soft cloth. (CAUTION: DO NOT let liquids
enter the heater).
4. DO NOT use alcohol, gasoline, abrasive powders, furniture polish or rough brushes to clean the
heater. This may cause damage or deterioration to the surface of the heater.
5. DO NOT immerse the heater in water
6. Wait until the heater is completely dry before use.
ATTENTION:
1. Always disconnect the heater from the electricity supply and allow it to cool before attempting to work on
it.
2. If the heater has collected dust or dirt inside the unit or around the heating element, have the unit
cleaned by a qualified service agent. Do not operate the heater in this condition.
3. The only maintenance required is cleaning of the external surfaces of the heater.
4. Do not touch the heating element with bare fingers, as residue from your hand could affect the life of the
lamp. If it is accidentally touched, remove the finger marks with a soft cloth moistened with mentholated
spirit or alcohol.
5. Do not attempt to repair or adjust any electrical or mechanical functions on this heater.
6. The heater contains no user serviceable parts. Should the product suffer damage or breakdown, it must
be returned to the manufacturer or its service agent.
7. Damaged supply cords to be replaced by the manufacturer, service agent or similarly qualified person in
order to avoid hazard.
Storage:
Storetheheaterinacool,drylocationwhennotinusetopreventdustanddirtbuildup.Usepackagingcartonto
store.
Ifyoudonotplantousetheheaterforextendedperiodsoftime,itisrecommendedthatitiscleanedandstored
(preferablyinitsoriginalpackaging)inacool,dryplace.
Donotdisposeofelectricalproductswithhouseholdwaste.Pleasecheckwithyourlocalcouncil
foradviceondisposalorrecycling.Ifelectricalappliancesaredisposedofinlandfillsordumps,
hazardoussubstancescanleakintothegroundwaterandgetintothefoodchain,damagingyour
healthandwell‐being.
POBOX1285,CRAWLEY,RH100LY,UK
EUAuthorisedRepresentative:AndaProductsBedrijvenweg177442CXNijverdalNederlandauthorisedrep@andaproducts.nl
497518A0621
Table of contents