Vesta GL-988 User manual

Rev20120706
GL-988
VESTA ALKALINE WATER IONIZER
OPERATION MANUAL
Ver. P-USA
Manufactured by GL Group Co., Ltd.
Warning: Incorrect installation and /or operation could void your valuable warranty.
Please protect your investment! Read this manual carefully.
GL-988

02 03
03
04/05
06/07
08
09
10
11
12
13
14
15
16/17/18/19
20
21
22
23
Now that’s POWER!
Industry-first technology!
AutoAdjust™ optimizer automatically adjusts the ionizing power giving
the best performance and ionization for your particular water source.
Smart Switch™ next generation SMPS power supply provides the most
stable and efficient power platform.
Patented Biostone Filter Technology ensures you
peace of mind, knowing your water is not only
alkaline and ionized, but cleaned.
AutoClean fully automatic post use cleaning
– unlike other ionizers, never wait for your
alkaline water and protect your investment.
Key Features:
• 9 high-efficiency platinum titanium electrodes deliver more power per
square inch than larger less sophisticated electrodes requiring large wattage.
Think small. Think efficient.
• Advanced self-diagnostic MICOM circuitry system
• Widest range of 274 pH and ORP selections
• Energy-saving advanced water flow sensor
• Compact size – smaller than other 9 electrode ionizers
• Sleek mirror faced elegant design by Samsung
• Aesthetic touch screen sensors
You have just purchased the finest, most advanced water system in the world!
Your new ionizer is designed to provide you with many years of the cleanest,
healthiest and most “functional” water available. There are many specific uses
and benefits of this amazing water, so read this manual carefully to learn how
to get both optimum performance out of your ionizer and to protect your investment.
Your new ionizer produces filtered alkaline, ionized water. Just exactly what is that?
Your ionizer employs computer accurate and selectable magnetic energy to perform
electrolysis through patented platinum bonded titanium electrodes inside a water cell.
Inside this advanced cell, the magnetic energy separates the water into an alkaline
(high pH) and acid (low pH) stream without using any chemicals. Ionizing the water
in this way re-structures the molecules and reduces their cluster size, binds extra
oxygen molecules, and concentrates ionized, absorbable and beneficial minerals like
Calcium, Magnesium and Potassium.
Contents
CONGRATULATIONS ON YOUR NEW PURCHASE!

Important safety warnings and precautions Installation warnings
04 05
Warning Legend
WARNING
The following symbols are used for different levels of warning.
DANGER
DANGER
CAUTION
: Could cause personal injury or have an adverse effect on health.
: Could cause damage to ionizer and possibly void your warranty.
: Please read these pages carefully. They contain very important information
to protect you and the valuable warranty on your ionizer.
If you have a chronic disease or serious health issue then please consult with a
health care provider before using the ionizer.
Do not drink alkaline water if you have achlorhydria.
Consult a health care provider before using acidic water if you have:
- Sensitive skin
- Allergies
Only use potable drinking water in your ionizer.
If on hard water please ask about pre-treatment options
Well water and water from smaller systems should be tested for safety before
using with an ionizer, and may require pre-filtering.
If you have never consumed alkaline water – start off with the lowest alkaline setting (level 1)
to begin with. Let your body adjust slowly and naturally for 4-7 days. After this initial adjustment
period, you may gradually increase the alkalinity of the water.
Customers in hard water areas may need additional treatment otherwise risk voiding their valuable
warranty. If unsure about the quality of your water please contact a water specialist.
Precautions : Do not use the following types of water.
Contaminated Salt water or Softened water
Turbid water How water over 104 Fahrenheit / 40 Celsius
Do not use your ionizer at
voltages other than specified
(AC 110V FOR USA). Use a GFI
outlet. Do not plug in your
ionizer where it will exceed
the rating of outlet or electric
wiring. Failure to do so can
result in fire, injury and/or
damage to yourself, wiring or
ionizer!
Protect your ionizer from
freezing temperatures or from
direct sunlight.
When using the unit in a cold
place, remove the filter after
use to prevent the filter from
freezing.
The acidic water hose should
be installed so that the end is
lower than the connection at
the elbow on the ionizer. The
water should flow freely down
from the elbow.
Be sure that the ionizer is
connected to a COLD water
source. Connecting it to a hot
water source could damage
the water cell or other parts
of the ionizer.
Keep the power cord and your
ionizer away from hot surfaces
or appliances - failure to do
so may result in electric shock
or fire!
Do not try to fix the ionizer
yourself. Call the dealer to
have it fixed by a qualified
technician.
Don't move the unit by the
front cover. The unit could be
damaged or cause you bodily
injury if the cover falls off and
the main body falls.
Move the unit by putting both
hands underneath it. This will
prevent the unit from falling
during movement.
Don't use the unit in a dusty
place. This may cause the unit
to malfunction.
If the power cord develops a
break or short, stop using the
unit and call customer service
to have it replaced.
If Acidic 3 level is used for 10+ minutes, the unit may power off as a protection againgst overheating.
The unit will operate again after it cools down.

06 07
Before installation, please check to ensure you have the following accessories.
Parts and features Parts and features
User manual Tubing
and Grey hose
Reagent drops
Optional diverter
Fuse
Flexible hose
Diverter
and screw anchors,
Hose clamp
Collett Tool
Installation accessories
Name of parts (Front)
Name of parts (Back)
Name of parts (Base)
1
7
8
2
5
4
3
6
10
911
9) Water Inlet (1/4”)
10) Power switch (On/Off)
11) Power socket
12) Water outlet (PVC)
6) Speaker grill
7) Wall mount hole
8) Filter covers (L/R)
1) Water outlet cap
2) Flexible hose
3) Display indicators
4) Buttons
5) Water supply valve (Knob)
12
Note: The Water inlet (¼”) comes with a
removable plug that needs to be removed
prior to cold water inlet tube installation.
Please see page 09 Installation to faucet
Step 6 for further instruction.”

08 09
Control panel features Installation to faucet
Control Panel Display
Audio functions
Installation to faucet
Place the water ionizer near
the sink where the ionizer
will be installed.
1 2
4
5
6
3
Remove the aerator from the
faucet
Remove the compression nut
from the diverter valve and
thread the plastic supply
tubing through it, making
sure to keep the threads of
the compression nut facing
the diverter valve.
Attach the plastic supply
tubing to the diverter by
pressing it onto the compres-
sion nipple and securing
the compression nut to the
diverter valve.
Attach the diverter valve to
the faucet using any included
adapter rings necessary. Be
sure to clean any exposed
threads and apply plumbers
tape to prevent leaks. If
installing to a pull-out/spray
stlye faucet, please contact
your dealer for information
on a specialty adapter that
may be required.
4567
8 9
10
11 12
13
14 15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
ORP Meter Indicator
Level Indicator
Sleep Indicator
Cleaning Indicator
Low Flow Indicator
Menu Selection Indicator
Check Unit Indicator
Alkaline Water Button
Menu Selector Button
Purified Water Button
Acidic Water Button
Filter Reset Button
pH Level Indicator
Primary Filter Life Indicator
Secondary Filter Life Indicator
“It is being washed now.”
“Clean water is being extracted now.”
“First grade alkaline water is being extracted now.”
“Second grade alkaline water is being extracted now.”
“Third grade alkaline water is being extracted now.”
“Fourth grade alkaline water is being extracted now.”
“First grade acidic water is being extracted now.”
“Second grade acidic water is being extracted now.”
“Third grade acidic water is being extracted now.”
When automatic cleaning is on
When Alkaline water is selected
When Acidic water is selected
When Purified water is selected
Optional Diverter
To connect water inlet hose, first remove the ¼” Red plug from the cold water inlet fitting by sliding the
collet tool between the Red plug and the white collett to release the Red plug. With the collet tool in
this position, the Red plug can be pulled out of the cold water inlet fitting. With the Red plug removed,
simply press the ¼” white water inlet tube into the water inlet fitting making sure to press firmly to ensure
a proper seal. To connect the Acidic water outlet, slide the hose clamp approximately 1” over one end of
the Grey Acidic water outlet hose. Slide the end with the hose clamp over the barbed Acidic water outlet
fitting. Using a pair of needle nose pliers, compress the two tabs of the hose clamp together, and slide the
hose clamp over the section of hose that is surrounding the barbed fitting and release the tabs.”
Table of contents
Other Vesta Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Atlantic Ultraviolet
Atlantic Ultraviolet Mighty Pure MP16A owner's manual

SunSun
SunSun CBG-500 Operation manual

Hayward
Hayward XStream Filtration Series owner's manual

Contech
Contech DownSpout StormFilter Operation and maintenance

Teka
Teka Airfilter MINI operating instructions

Wisy
Wisy LineAir 100 Installation and operating instructions

Schaffner
Schaffner Ecosine FN3446 Series User and installation manual

Pentair
Pentair FLECK 4600 SXT Installer manual

H2O International
H2O International H20-500 product manual

Renkforce
Renkforce 2306241 operating instructions

Neo-Pure
Neo-Pure TL3-A502 manual

STA-RITE
STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual