2
Table of contents: page
1. Description of construction ........................................................................................................................ 3
2. Instructions for product disposal after its service life expiration ................................................................ 3
3. Guarantee.................................................................................................................................................. 4
3
1. Description of construction
The storage tanks are used as accumulators that store thermal energy produced by the solid fuel boiler and
this energy is then continuously passed to heating system of central heating and hot service water.
The storage tanks constitute an accessory to:
•Systems with heat pump
•Solar systems
•Solid fuel boilers.
The storage tanks have 8 connections on the front side and 1 on top, allowing the connection of different
options. As standard the tanks are equipped with three sockets for sensors and water drain valve at the
bottom of the tank. Storage tanks can be supplied without thermal insulation or with thermal insulation.
The tank is removable and made of soft polyurethane foam. If we want to install a solid fuel boiler in cascade
with boiler on heating oil or gas boiler, with a fireplace and solar panels then the installation of storage tank is
recommended. In case of connecting the solar panels it is necessary to separate heating water circuit from
the antifreeze circuit in the solar system for example by using a external plate heat exchanger.
It is also recommended in case of boilers that are adapted to operation in an open system and you want to
have an installation working in a closed system. The tanks are not enamelled therefore they only are
adapted to the storage of neutral media (e.g. demineralised heating water, glycol, etc.). The maximum
allowable operating pressure in the tank is 3 bar (0.3 MPa).
In the table below there are given the values of wall thickness and material used for the manufacture of
storage tanks AkuECONOMY:
Storage tank
Tank
diamete
r
[Ø]
Bottom
Material
Shells
Material
Material thickness Material thickness
Nominal
[mm] Minimal
[mm]
S235JR
Nominal
[mm] Minimal
[mm]
S235JR
500 600 3 2,5 3 2,5
800 790 3 2,5 3 2,5
1000 790 4 2,5 3 2,5
1500 900 4 2,5 3 2,5
2000 1100 4 2,5 3 2,5
2. Instructions for product disposal after its service life expiration
VIADRUS a.s. is a contractual partner of the firm EKO–KOM a.s., its client number being F00120649.
Packages are in compliance to ČSN EN 13427.
Because the product is constructed of common materials its individual parts are recommended to be
disposed through a firm dealing with waste collection and disposal.
The heater wrapping should be disposed of in following way:
- plastic foil, cardboard cover and the wooden pallet into the common waste
- metal strap for strapping – through a firm dealing with waste collection and disposal
- wooden base, is designated for a single usage and no longer can be used as a product. Its disposal is
subject to Act. 477/ 2001 Sb. a 185/2001 Coll.as amended.
In case that the product has lost its serviceability you can take advantage of product “take back
service” (if this is established); in case that the originator has declared that it is a scrap it must be
handled according to the valid legislation of relevant country.
4
3. Guarantee
Guarantee of an enamel storage tank is 24 months.
The guarantee includes the above period, but the maximum the period of warranty plus 12 months from the
date of manufacture.
The manufacturer for the validity of his guarantee requires:
–To inspect storage tanks regularly once a year. Only an authorized service organization is qualified to
exercise the inspections.
–To document all records on carried out guarantee and after-guarantee repairs and annual inspections in
an annex to this manual guarantee certificate.
Every fault must be notified immediately after having been discovered and always in writing.
In case of an infringement of above instructions the guarantees provided by the manufacturer will
not be recognized.
The guarantee does not apply to:
- faults caused by improper assembly and improper attendance of the product and faults caused
by improper maintenance;
- product damage arisen from transport or other mechanical damage;
- the faults caused by an unsuitable way of storing;
- faults caused by failure to observe instructions stated in this manual.
The manufacturer reserves the right of alterations made within the product innovation that needn’t
be included in this manual
5
AkuECONOMY 200 L
AkuECONOMY 300 L
AkuECONOMY 500 L
AkuECONOMY 800 L
AkuECONOMY 1000 L
AkuECONOMY 1500 L
AkuECONOMY 2000 L
0
GS8
GS9
GS10
GS11
L
0
GS1
GS2
GS3
GS4
GS5
GS6
GS7
SPUST
water outlet
6
Technical parameters Designation
AkuECONOMY 200 L
Volume l 200
Maxim. permissible temperature
o
C 95
Maxim. permissible pressure bar 3
Dimensions
Water drain valve
Height of connection for boiler water GS1 mm 220
Height of connection for sensors or
thermometer GS2 mm 312
Height of connection for boiler water GS3 mm 483
Height of connection for sensors or
thermometer GS4 mm 603
Height of connection for boiler water GS5 mm 785
Height of connection for sensors or
thermometer GS6 mm 885
Height of connection for boiler water GS7 mm 220
Height of connection for boiler water GS8 mm 553
Height of connection for sensors or
thermometer GS9 mm 785
Height of equipment L mm 1105
Tank diameter (without insulation) d Ø 550
Diameter with insulation) D Ø 700
Insulation made of hardened polyurethane
foam mm 70
External shell skay
Hydraulic connections
Boiler water supply/ return branch of heating water internal
thread 1 1/2”
Connections for sensor and thermometer internal
thread 1/2"
Water drain valve internal
thread 1”
Weight without insulation (empty) kg 60
7
Technical parameters Designation
AkuECONOMY 300 L
Volume l 300
Maxim. permissible temperature
o
C 95
Maxim. permissible pressure bar 3
Dimensions
Water drain valve
Height of connection for boiler water GS1 mm 220
Height of connection for boiler water GS2 mm 390
Height of connection for sensors or
thermometer GS3 mm 500
Height of connection for boiler water GS4 mm 730
Height of connection for sensors or
thermometer GS5 mm 900
Height of connection for boiler water GS6 mm 1070
Height of connection for sensors or
thermometer GS7 mm 1235
Height of connection for boiler water GS8 mm 220
Height of connection for boiler water GS9 mm 560
Height of connection for boiler water GS10
mm 900
Height of connection for boiler water GS11
mm 1235
Height of equipment L mm 1370
Tank diameter (without insulation) d Ø 550
Diameter with insulation) D Ø 700
Insulation made of hardened polyurethane
foam mm 70
External shell skay
Hydraulic connections
Boiler water supply/ return branch of heating water internal
thread 1 1/2”
Connections for sensor and thermometer internal
thread 1/2"
Water drain valve internal
thread 1”
Weight without insulation (empty) kg 75
8
Technical parameters Designation
AkuECONOMY 500 L
Volume l 500
Maxim. permissible temperature
o
C 95
Maxim. permissible pressure bar 3
Dimensions
Water drain valve
Height of connection for boiler water GS1 mm 225
Height of connection for boiler water GS2 mm 460
Height of connection for sensors or thermometer GS3 mm 620
Height of connection for boiler water GS4 mm 920
Height of connection for sensors or thermometer GS5 mm 1155
Height of connection for boiler water GS6 mm 1385
Height of connection for sensors or thermometer GS7 mm 1615
Height of connection for boiler water GS8 mm 225
Height of connection for boiler water GS9 mm 690
Height of connection for boiler water GS10
mm 1155
Height of connection for boiler water GS11
mm 1615
Height of equipment L mm 1905
Tank diameter (without insulation) d Ø 600
Diameter with insulation) D Ø 800
Insulation made of hardened polyurethane foam mm 100
External shell skay
Hydraulic connections
Boiler water supply/ return branch of heating water internal
thread 1 1/2”
Connections for sensor and thermometer internal
thread 1/2"
Water drain valve internal
thread 1”
Weight without insulation (empty) kg 105
9
Technical parameters Designation
AkuECONOMY 800 L
Volume l 800
Maxim. permissible temperature
o
C 95
Maxim. permissible pressure bar 3
Dimensions
Water drain valve
Height of connection for boiler water GS1 mm 250
Height of connection for boiler water GS2 mm 435
Height of connection for sensors or thermometer GS3 mm 570
Height of connection for boiler water GS4 mm 820
Height of connection for sensors or thermometer GS5 mm 1020
Height of connection for boiler water GS6 mm 1215
Height of connection for sensors or thermometer GS7 mm 1410
Height of connection for boiler water GS8 mm 250
Height of connection for boiler water GS9 mm 620
Height of connection for boiler water GS10
mm 1020
Height of connection for boiler water GS11
mm 1410
Height of equipment L mm 1730
Tank diameter (without insulation) d Ø 790
Diameter with insulation) D Ø 990
Insulation made of soft polyurethane foam mm 100
External shell skay
Hydraulic connections
Boiler water supply/ return branch of heating water internal
thread 1 1/2”
Connections for sensor and thermometer internal
thread 1/2"
Water drain valve internal
thread 1”
Weight without insulation (empty) kg 125
10
Technical parameters Designation
AkuECONOMY 1000 L
Volume l 1000
Maxim. permissible temperature
o
C 95
Maxim. permissible pressure bar 3
Dimensions
Water drain valve
Height of connection for boiler water GS1 mm 250
Height of connection for boiler water GS2 mm 500
Height of connection for sensors or thermometer GS3 mm 570
Height of connection for boiler water GS4 mm 980
Height of connection for sensors or thermometer GS5 mm 1240
Height of connection for boiler water GS6 mm 1485
Height of connection for sensors or thermometer GS7 mm 1730
Height of connection for boiler water GS8 mm 250
Height of connection for boiler water GS9 mm 740
Height of connection for boiler water GS10
mm 1240
Height of connection for boiler water GS11
mm 1730
Height of equipment L mm 2050
Tank diameter (without insulation) d Ø 790
Diameter with insulation) D Ø 990
Insulation made of soft polyurethane foam mm 100
External shell skay
Hydraulic connections
Boiler water supply/ return branch of heating water internal
thread 1 1/2”
Connections for sensor and thermometer internal
thread 1/2"
Water drain valve internal
thread 1”
Weight without insulation (empty) kg 150
11
Technical parameters Designation AkuECONOMY 1500 L
Volume l 1500
Maxim. permissible temperature
o
C 95
Maxim. Permissible pressure bar 3
Dimensions
Water drain valve
Height of connection for boiler water GS1 mm 330
Height of connection for boiler water GS2 mm 705
Height of connection for sensors or thermometer GS3 mm 915
Height of connection for boiler water GS4 mm 1325
Height of connection for sensors or thermometer GS5 mm 1640
Height of connection for boiler water GS6 mm 1950
Height of connection for sensors or thermometer GS7 mm 2260
Height of connection for boiler water GS8 mm 330
Height of connection for boiler water GS9 mm 1015
Height of connection for boiler water GS10
mm 1640
Height of connection for boiler water GS11
mm 2260
Height of equipment L mm 2700
Tank diameter (without insulation) d Ø 900
Diameter with insulation) D Ø 1100
Insulation made of soft polyurethane foam mm 100
External shell skay
Hydraulic connections
Boiler water supply/ return branch of heating water internal
thread 1 1/2”
Connections for sensor and thermometer internal
thread 1/2"
Water drain valve internal
thread 1”
Weight without insulation (empty) kg 210
12
Technical parameters Designation
AkuECONOMY 2000 L
Volume l 2000
Maxim. permissible temperature
o
C 95
Maxim. Permissible pressure bar 3
Dimensions
Water drain valve
Height of connection for boiler water GS1 mm 385
Height of connection for boiler water GS2 mm 660
Height of connection for sensors or thermometer GS3 mm 800
Height of connection for boiler water GS4 mm 1205
Height of connection for sensors or thermometer GS5 mm 1480
Height of connection for boiler water GS6 mm 1755
Height of connection for sensors or thermometer GS7 mm 2025
Height of connection for boiler water GS8 mm 385
Height of connection for boiler water GS9 mm 930
Height of connection for boiler water GS10
mm 1480
Height of connection for boiler water GS11
mm 2025
Height of equipment L mm 2410
Tank diameter (without insulation) d Ø 1100
Diameter with insulation) D Ø 1300
Insulation made of soft polyurethane foam mm 100
External shell skay
Hydraulic connections
Boiler water supply/ return branch of heating water internal
thread 1 1/2”
Connections for sensor and thermometer internal
thread 1/2"
Water drain valve internal
thread 1”
Weight without insulation (empty) kg 235
13
Intended for user VIADRUS a.s.,
Bezručova 300
735 81 Bohumín
Certificate of warranty and Certificate of quality and completeness of
the storage tank:
AkuECONOMY ……….
Serial number of the storage tank ………………………………………………………………………………
User (surname, first name) ………………………………………………………………………………
Address (street, city, zip code) ………………………………………………………………………………
Phone / Fax ………………………………………………………………………………
Overpressure in the inlet water pipe ................................... kPa
Conditions of the validity of the warranty:
•Installation of the storage tank must be carried out according to " Operating and installation
manual for storage tanks” by a professional firm
•Putting Into operation must be carried out according to "Operating and installation manual for
storage tanks” by a contractual service organization accredited by the manufacturer
•The faults must be removed by a contractual service organization accredited by the manufacturer
The completeness of the supplied storage tank is guaranteed by the seller
The certificate of warranty is void if not filled out.
The user confirms that:
•he has received the "Operating and Installation manual"
•he has been acquainted with the operation and maintenance of the storage tank
……………………………………..
……………………………………..
……………………………………..
Production date Stamp of the manufacturer Checked by: (signature)
……………………………………..
……………………………………...
……………………………………..
Date of installation Installation company
(stamp, signature) Signature of user
…………………………………….
……………………………………..
……………………………………..
Date of putting into operation Contractual service organization
(stamp, signature) Signature of user
14
Enclosure to the certificate of warranty for the customer- user
Record of the carried out warranty and post warranty repairs and regular annual checks of the
product
Date of
record Carried out activity
Contractual service
organization
(signature, stamp)
Signature of
customer
15
Intended for the contractual service organization VIADRUS a.s.,
Bezručova 300
735 81 Bohumín
Certificate of warranty and Certificate of quality and completeness of
the storage tank:
AkuECONOMY ……….
Serial number of the storage tank ………………………………………………………………………………
User (surname, first name) ………………………………………………………………………………
Address (street, city, zip code) ………………………………………………………………………………
Phone / Fax ………………………………………………………………………………
Overpressure in the inlet water pipe ................................... kPa
Conditions of the validity of the warranty:
•Installation of the storage tank must be carried out according to " Operating and installation
manual for storage tanks” by a professional firm
•Putting Into operation must be carried out according to "Operating and installation manual for
storage tanks” by a contractual service organization accredited by the manufacturer
•The faults must be removed by a contractual service organization accredited by the manufacturer
The completeness of the supplied storage tank is guaranteed by the seller
The certificate of warranty is void if not filled out.
The user confirms that:
•he has received the "Operating and Installation manual"
•he has been acquainted with the operation and maintenance of the storage tank
……………………………………..
……………………………………..
……………………………………..
Production date Stamp of the manufacturer Checked by: (signature)
……………………………………..
……………………………………...
……………………………………..
Date of installation Installation company
(stamp, signature) Signature of user
…………………………………….
……………………………………..
……………………………………..
Date of putting into operation Contractual service organization
(stamp, signature) Signature of user
16
17
Intended for the manufacturer VIADRUS a.s.,
Bezručova 300
735 81 Bohumín
Certificate of warranty and Certificate of quality and completeness of
the storage tank:
AkuECONOMY ……….
Serial number of the storage tank ………………………………………………………………………………
User (surname, first name) ………………………………………………………………………………
Address (street, city, zip code) ………………………………………………………………………………
Phone / Fax ………………………………………………………………………………
Overpressure in the inlet water pipe ................................... kPa
Conditions of the validity of the warranty:
•Installation of the storage tank must be carried out according to " Operating and installation
manual for storage tanks” by a professional firm
•Putting Into operation must be carried out according to "Operating and installation manual for
storage tanks” by a contractual service organization accredited by the manufacturer
•The faults must be removed by a contractual service organization accredited by the manufacturer
The completeness of the supplied storage tank is guaranteed by the seller
The certificate of warranty is void if not filled out.
The user confirms that:
•he has received the "Operating and Installation manual"
•he has been acquainted with the operation and maintenance of the storage tank
……………………………………..
……………………………………..
……………………………………..
Production date Stamp of the manufacturer Checked by: (signature)
……………………………………..
……………………………………...
……………………………………..
Date of installation Installation company
(stamp, signature) Signature of user
…………………………………….
……………………………………..
……………………………………..
Date of putting into operation Contractual service organization
(stamp, signature) Signature of user
18
19
20
Date of updating 46/2012 – GB

This manual suits for next models

11

Other Viadrus Water Heater manuals

Viadrus Space Energy 200V User manual

Viadrus

Viadrus Space Energy 200V User manual

Viadrus AkuDuo 350/100 L User manual

Viadrus

Viadrus AkuDuo 350/100 L User manual

Viadrus 200 I User manual

Viadrus

Viadrus 200 I User manual

Viadrus Space Energy 300V User manual

Viadrus

Viadrus Space Energy 300V User manual

Viadrus AkuCOMBI 500/160 L Specification sheet

Viadrus

Viadrus AkuCOMBI 500/160 L Specification sheet

Popular Water Heater manuals by other brands

Chronomite ER-90 208 3P Series Assembly, installation and operation instructions

Chronomite

Chronomite ER-90 208 3P Series Assembly, installation and operation instructions

Haier HP200M2 Installation and service manual

Haier

Haier HP200M2 Installation and service manual

Rinnai REU-VR1620WS Solar 20 Operation & installation manual

Rinnai

Rinnai REU-VR1620WS Solar 20 Operation & installation manual

Noritz N-0751M Instructional manual

Noritz

Noritz N-0751M Instructional manual

Scheer MH Series Installation and maintenance instructions

Scheer

Scheer MH Series Installation and maintenance instructions

Bosch Optiflow Professional GWH12 installation manual

Bosch

Bosch Optiflow Professional GWH12 installation manual

Paloma PH-246CWHA Owner's guide and installation instructions

Paloma

Paloma PH-246CWHA Owner's guide and installation instructions

Takagi T-M32 Installation manual and owner's guide

Takagi

Takagi T-M32 Installation manual and owner's guide

usha Aqua Horizon AH15AH Instruction manual and warranty card

usha

usha Aqua Horizon AH15AH Instruction manual and warranty card

Rheem 65 Specification sheet

Rheem

Rheem 65 Specification sheet

Electrolux EYL85066BT user manual

Electrolux

Electrolux EYL85066BT user manual

Modena Conesso Series User manual book

Modena

Modena Conesso Series User manual book

Siemens DE18401 Installation and operating instructions

Siemens

Siemens DE18401 Installation and operating instructions

Viessmann VITOCELL 300B Installation and service instructions

Viessmann

Viessmann VITOCELL 300B Installation and service instructions

Lotus LTS-3HP Installation and operation guide

Lotus

Lotus LTS-3HP Installation and operation guide

Siemens D03670D4 Installation and operating instructions

Siemens

Siemens D03670D4 Installation and operating instructions

Webasto DBW 2010 installation instructions

Webasto

Webasto DBW 2010 installation instructions

Rinnai RIN80E24 owner's manual

Rinnai

Rinnai RIN80E24 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.