Contact Us +1 844 GO VIAVI)
(+1 844 468 4284)
To reach the VIAVI office nearest you,
visit viavisolutions.com/contacts.
© 2020 VIAVI Solutions Inc.
Product specifications and descriptions in this
document are subject to change without notice.
7. Press the Results Soft Key to view the
Test Results screen.
8. Tap the Signal Lead tab at the bottom of
the screen and tap the RTS and DTR
buttons.
9. Press the Restart soft key .
Figure 4: Test Results Screen, Signal Leads
10. Using the drop-down menus, select
“HS Datacom/BERT” for the right results
display.
11. Allow the test to run for desired duration
and verify the following:
•Pattern Sync LED is green.
•Bit Error Rate result does not exceed
your required threshold. (0.00E+00 if
pass/fail threshold unknown)
Figure 5: Test Results Screen, HS Datacom/BERT
12. In the T-BERD’s Quick Config menu,
change “Pattern” to the next value in the
test plan.
13. Press the Restart soft key to reset
results.
14. Allow test to run for desired duration and
verify the following:
•Pattern Sync LED is green.
•Bit Error Rate does not exceed your
required threshold. (0.00E+00 if
pass/fail threshold unknown)
15. Repeat steps 12 through 14 for all Patterns
in the test plan.