Viavi MAP-200 User manual

Multiple Application Platform
MAP-200
MAP-200 Optical Switch, mOSW-C1
Installation and User Guide
22112369-120 R000
Standard
June 2016

MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 2

MAP-200 Optical Switch mOSW-C1 Installation and User Guide Page 3
June 2016 Document Number: 22112369-120 R000 Status: Standard
Contents
Chapter 1: Document History............................................................................................8
Chapter 2: About this Guide..............................................................................................9
Notice .........................................................................................................................................9
Purpose and Scope ....................................................................................................................9
Assumptions...............................................................................................................................9
Copyright....................................................................................................................................9
Copyright Release ....................................................................................................................10
Trademarks...............................................................................................................................10
Document Ordering Information................................................................................................10
Terms and conditions................................................................................................................10
Chapter 3: Safety & Compliance ...................................................................................... 11
Symbols used in this manual.....................................................................................................11
General Safety..........................................................................................................................12
Labels.......................................................................................................................................13
Regulatory Compliance.............................................................................................................14
Calibration.................................................................................................................................15
WEEE Directive Compliance.....................................................................................................16
CE Certificate............................................................................................................................17
China RoHS Certificate.............................................................................................................18
Chapter 4: General Information ..................................................................................... 19
Key Features............................................................................................................................19
Standard Accessories...............................................................................................................19
Theory of Operation..................................................................................................................20
Configurations...........................................................................................................................20
1CxN Configuration...............................................................................................................20
2DxN Configuration...............................................................................................................21
2ExN Configuration...............................................................................................................21
2Xx2 Configuration................................................................................................................22
Power Trim............................................................................................................................22
Chapter 5: Getting Started ............................................................................................. 24
Required Software....................................................................................................................24
Before Initializing and Operating the Unit..................................................................................24

Contents
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 4
Initial Inspection........................................................................................................................24
Cleaning Instructions ................................................................................................................25
Cleaning the Equipment........................................................................................................25
Cleaning Optical Connectors.................................................................................................25
Cleaning Jumper Connectors................................................................................................27
Installing the mOSW-C1 into a MAP-200 Chassis.....................................................................28
Chapter 6: The mOSW-C1 Graphical User Interface (GUI) .............................................30
Initial Screen.............................................................................................................................30
Instrument Summary.................................................................................................................31
Instrument Summary View....................................................................................................31
1x2 and 2x2 GUI.......................................................................................................................31
Detailed View 1x2 Switch......................................................................................................32
Detailed View 2x2 Switch......................................................................................................33
C-Type GUI...............................................................................................................................33
D-Type GUI...............................................................................................................................34
E-Type GUI...............................................................................................................................35
Simplified Views........................................................................................................................36
Simplified Instrument Summary View....................................................................................36
Other Simplified views...........................................................................................................37
Naming a Cassette ...................................................................................................................38
Chapter 7: Updating the Firmware................................................................................. 42
Updating the MAP-200 Firmware..............................................................................................42
Updating the mOSW-C1 Firmware............................................................................................43
Chapter 8: Remote Commands.......................................................................................46
Definitions.................................................................................................................................46
SCPI Commands Command Tables .........................................................................................46
Common Commands............................................................................................................47
User Commands...................................................................................................................48
Common SCPI Commands.......................................................................................................49
*CLS .................................................................................................................................49
*ESE.................................................................................................................................50
*ESE?...............................................................................................................................52
*ESR?...............................................................................................................................53
*IDN? ................................................................................................................................55
*OPC.................................................................................................................................56
*OPC?...............................................................................................................................57
*RST .................................................................................................................................58
*SRE.................................................................................................................................59
*SRE?...............................................................................................................................60
*STB?................................................................................................................................61
*TST?................................................................................................................................63
*WAI..................................................................................................................................64
*SAV.................................................................................................................................65
*RCL .................................................................................................................................66
Common Application Commands..............................................................................................67
:SYSTem:ERRor?.............................................................................................................67
:BUSY?.............................................................................................................................68

Contents
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 5
:RESet...............................................................................................................................69
:TEST?..............................................................................................................................70
:CONFig?..........................................................................................................................71
:INFOrmation?...................................................................................................................73
:LOCK...............................................................................................................................74
:LOCK?.............................................................................................................................75
LOCK:RELEase................................................................................................................76
:DEVice:INFOrmation?......................................................................................................77
:FAULt:SLOT?...................................................................................................................78
:FAULt:DEVice?................................................................................................................79
:STATus:DEVice?.............................................................................................................81
:STATus:RESet.................................................................................................................83
:ROUTe:CLOSe................................................................................................................83
:ROUTe:CLOSe?..............................................................................................................84
:ROUTe:TRIM...................................................................................................................85
:ROUTe:TRIM?.................................................................................................................86
:ROUTe:WAVelength........................................................................................................87
:ROUTe:WAVelength?......................................................................................................88
:ROUTe:CHANnel:DEScription..........................................................................................89
:ROUTe:CHANnel:DEScription?........................................................................................90
:ROUTe:MONitor?.............................................................................................................91
Chapter 9: Specifications ................................................................................................ 92
mOSW-C1 Parameters.............................................................................................................92
Chapter 10: Technical Support ........................................................................................98
Chapter 11: Service ...........................................................................................................99
Storing and Shipping.................................................................................................................99
Claims and Repackaging ......................................................................................................99
Packing Guidelines With Original Packaging.........................................................................99
Packing Guidelines Without Original Packaging....................................................................99
Returning Shipments to Viavi..............................................................................................100
Chapter 12: Glossary .......................................................................................................101

Figures
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 6
Figures
Figure 1: MAP-200 mOSW Cassette Label: Side Panel...................................................................... 13
Figure 2: MAP-200 mOSW Cassette Labels: Front Panel.................................................................... 13
Figure 3: mOSW Optical Switch........................................................................................................... 19
Figure 4: 1CxN Configuration.............................................................................................................. 20
Figure 5: 2DxN Configuration............................................................................................................... 21
Figure 6: 2Ex2 Configuration ............................................................................................................... 21
Figure 7: 2Xx2 Configuration.............................................................................................................. 22
Figure 8: Front Panel Optical Adapter.................................................................................................. 26
Figure 9: Connector cleaning (connector type can vary)...................................................................... 27
Figure 10: Removing a Faceplate........................................................................................................ 28
Figure 11: Inserting an Optical Cassette.............................................................................................. 29
Figure 12: Typical PTRIM impact for 1CxN with 24 ports or less.......................................................... 95
Figure 13: Typical PTRIM impact for 1CxN with more than 24 ports.................................................... 95

Tables
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 7
Tables
Table 1: Safety Symbols...................................................................................................................... 11
Table 2: mOSW-C1 M xN, N ≥ 4 Specifications ................................................................................... 92
Table 3: mOSW-C1 [1x2] and [2x2] Parameters.................................................................................. 96

MAP-200 Optical Switch mOSW-C1 Installation and User Guide Page 8
June 2016 Document Number: 22112369-120 R000 Status: Standard
Chapter 1: Document History
Document Number /
Revision
Date Comment
22112369-120 R000 June 2016
Initial release with new number.
Changed branding from JDSU to Viavi.
Note that diagrams are not necessarily reflective of the
company name change from JDSU to Viavi.
22021771 R000 March 2013 First release

MAP-200 Optical Switch mOSW-C1 Installation and User Guide Page 9
June 2016 Document Number: 22112369-120 R000 Status: Standard
Chapter 2: About this Guide
Notice
Every effort was made to ensure that the information in this manual was accurate at
the time of printing. However, information is subject to change without notice, and
Viavi reserves the right to provide an addendum to this manual with information not
available at the time that this manual was created.
Purpose and Scope
The purpose of this guide is to help you successfully use the mOSW-C1 cassette.
This guide includes task-based instructions that describe how to install, configure,
use, and troubleshoot the mOSW-C1. Additionally, this guide provides a complete
description of Viavi warranty, services, and repair information, including terms and
conditions of the licensing agreement.
Assumptions
This guide is intended for novice and intermediate users who want to use the
mOSW-C1 effectively and efficiently. Viavi assumes that the user is familiar with
basic telecommunication concepts and terminology.
Copyright
© Copyright June 2016 Viavi Solutions Inc. All rights reserved. Viavi and the Viavi
logo are trademarks of Viavi Solutions Inc. (“Viavi”). All other trademarks and
registered trademarks are the property of their respective owners. No part of this
guide may be reproduced or transmitted, electronically or otherwise, without written
permission of the publisher.

About this Guide
Copyright Release
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 10
Copyright Release
Reproduction and distribution of this guide is authorized for US Government
purposes only.
Trademarks
Viavi is a trademark of Viavi Solutions Inc. in the United States and other countries.
Microsoft, Windows, Windows CE, Windows NT, MS-DOS, Excel, Word and
Microsoft Internet Explorer are either trademarks or registered trademarks of
Microsoft Corporation in the United States and/or other countries. All trademarks and
registered trademarks are the property of their respective companies.
Document Ordering Information
This guide is a product of Viavi's Technical Information Development Department,
issued as part of the MAP-200 suite of documents. The catalog number for this guide
is 22112369-120 R000. It is distributed on the MAP-200 USB drive, 21127440,
shipped with MAP-200 chassis and cassettes.
Terms and conditions
Specifications, terms, and conditions are subject to change without notice. The
provision of hardware, services, and/or software are subject to Viavi’s standard terms
and conditions, available at www.viavisolutions.com/terms.

MAP-200 Optical Switch mOSW-C1 Installation and User Guide Page 11
June 2016 Document Number: 22112369-120 R000 Status: Standard
Chapter 3: Safety & Compliance
Symbols used in this manual
The following symbols and messages can be marked on the unit. Observe all safety
instructions that are associated with a symbol.
Table 1: Safety Symbols
Symbol
Description
CAUTION
See the user manual for instructions on handling and operating the unit safely.
The procedure can result in serious damage to or destruction of the unit if not
carried out following instructions for proper use.
ELECTROSTATIC DISCHARGE (ESD).
See the user manual for instructions on handling and operating the unit safely.
WARNING: LASER SAFETY
The procedure can result in serious injury if not carried out in proper
compliance with all safety instructions. Ensure that all conditions
necessary for safe handling and operation are met before proceeding.
WARNING
The procedure can result in serious injury or loss of life if not carried out in
proper compliance with all safety instructions. Ensure that all conditions
necessary for safe handling and operation are met before proceeding.

Safety & Compliance
General Safety
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 12
General Safety
The MAP-200 system, including functional cassettes complies with CSA/UL/IEC
61010-1.
The following safety information must be observed whenever the unit is operated,
serviced, or repaired. Failure to comply with any of these instructions or with any
precaution or warning contained in this user manual is in direct violation of the
standards of design, manufacture, and intended use of the unit. Viavi assumes no
liability for the customer's failure to comply with any of these safety requirements.
WARNING
To avoid the risk of injury or death always observe the following precautions
before connecting the unit to power, during initialization and during operation of
the unit:
•Use only the type of power cord supplied with the unit.
•Do not use the unit outdoors.
•To prevent potential fire or shock hazard, do not expose the unit to
any source of excessive moisture.
•Do not perform any operating or maintenance procedure that not
described in this user manual. All other repairs must be done by a
qualified Viavi professional.
•Do not operate the unit with its covers or panels removed.
WARNING: LASER SAFETY
To avoid the risk of injury always observe the following precautions before
connecting the unit to power, during initialization and during operation of the
unit:
•Never look into the end of an optical cable connected to an optical
output device that is operating. Laser radiation is invisible, and direct
exposure can severely injure the human eye.
•Turning off the power to the device does not always block the
externally supplied radiation to the connector at the output of the
unit.
•Do not perform any operating or maintenance procedure that not
described in this user manual. All other repairs must be done by a
qualified Viavi professional.
•
Do not operate the unit with its covers or panels removed.

Safety & Compliance
Labels
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 13
Labels
Figure 1: MAP-200 mOSW Cassette Label: Side Panel
Figure 2: MAP-200 mOSW-C1 Cassette Labels: Front Panel

Safety & Compliance
Regulatory Compliance
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 14
Regulatory Compliance
•The MAP-200, including functional cassettes complies to: CE requirement
EN61010-1:2001, UL61010-1 and CAN/CSA-C22.2 No.61010-1-04 (see CE
certificate of compliance).
•The MAP-200 is in Installation Category (Over voltage Category) II under IEC
664. The unit is in the Pollution Degree 2 category under IEC61010-1 Safety
Requirements for Electrical Equipment for Measurement, Control, and Laboratory
Use and CAN/CSA-C22.2 No. 61010-1-04 Safety Requirements for Electrical
Equipment for Measurement Control, and Laboratory Use, Part I: General
Requirements.

Safety & Compliance
Calibration
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 15
Calibration
This product is shipped with a certificate of conformance. Calibration is not required.

Safety & Compliance
WEEE Directive Compliance
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 16
WEEE Directive Compliance
Viavi has established processes in compliance with the Waste Electrical and
Electronic Equipment (WEEE) Directive, 2002/96/EC.
This product should not be disposed of as unsorted municipal waste and should be
collected separately and disposed of according to your national regulations. In the
European Union, all equipment purchased from Viavi after 2005-08-13 can be
returned for disposal at the end of its useful life. Viavi will ensure that all waste
equipment returned is reused, recycled, or disposed of in an environmentally friendly
manner, and in compliance with all applicable national and international waste
legislation.
It is the responsibility of the equipment owner to return the equipment to Viavi for
appropriate disposal. If the equipment was imported by a reseller whose name or
logo is marked on the equipment, then the owner should return the equipment
directly to the reseller. Instructions for returning waste equipment to Viavi can be
found in the Environmental section of Viavi’s web site at
http://www.viavisolutions.com/en-us/corporate/about-us/policies-and-standards .If
you have questions concerning disposal of your equipment, contact Viavi’s WEEE
Program Management team at weee.emea@viaisolutions.com .

Safety & Compliance
CE Certificate
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 17
CE Certificate

Safety & Compliance
China RoHS Certificate
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 18
China RoHS Certificate

MAP-200 Optical Switch mOSW-C1 Installation and User Guide Page 19
June 2016 Document Number: 22112369-120 R000 Status: Standard
Chapter 4: General Information
The MAP-200 mOSW Optical Switch is based on Viavi expanded beam and
alignment technologies and exhibits low insertion loss (IL) and high return loss (RL).
It is available in single-switch configurations from 1x2 up to 1x64 and dual
independent switch configurations from 1x2 up to 1x24 and 8 by 1x2.
An important element of an optical test bed, optical switches increase throughput by
enabling time-saving automation, reduce uncertainty from repeated connector mating
and maximizes the use of expensive testers.
Figure 3: mOSW Optical Switch
Key Features
The key features include:
•Low insertion loss ≤ 0.7 dB
•Low polarization dependent loss ≤ 0.04 dB
•Wide wavelength range
•High return loss ≥ 62 dB
Standard Accessories
•USB flash drive with

General Information
Theory of Operation
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 20
oMAP-200 User’s Manual
omOSW User’s Manual
•Certificate of Conformance
•Test Report
Theory of Operation
Large channel count switches use precision motors to position input and/or output
channels for selection. They have one or two input channels, and multiple output
channels. The switch is bidirectional and so inputs and outputs are interchangeable.
Configurations
1CxN Configuration
0
3
2
1
4
N
.
.
A
Figure 4: 1CxN Configuration
The 1CxN configuration allows a single common input to be switched to any of the N
outputs.
This manual suits for next models
1
Table of contents
Other Viavi Switch manuals
Popular Switch manuals by other brands

Perle
Perle IDS-509G quick start guide

TP-Link
TP-Link Omada SG2218P installation guide

Techroutes
Techroutes S3756 Hardware installation manual

HP
HP StorageWorks 2/140 - Director Switch release note

Panasonic
Panasonic AV-UHS500P operating instructions

UTAH SCIENTIFIC