This Quick Start Guide is intended for experienced installing technicians. It is a basic reference to ensure all connections are properly made.
It is for models VAX-CR-35L-OSDP and VAX-CSR-6.2-OSDP. For additional information please refer to Vicon's website www.vicon-security.com.
1.0 Introduction
A key component of a physical security electronic access control
system, a mobile-ready reader combining BLE and contactless
smartcard technologies is based on RFID technology. In operation it is
capable of reading data stored on a contactless smartcard credential
via high frequency—or reading data from mobile credential stored in a
smartphone’s wallet app via BLE technology—and without physical
contact, and then passing the data obtained to the physical access
control system. Access control systems typically manage and record
the movement of individuals through a protected area, such as a
locked door.
2.0 Mounting Provisions
Each reader may be installed either indoors or outdoors. Mounting
options shown in the table below. Use supplied #6 mounting screws,
or equivalent security screws, for installation.
Model Mullion Mount Single-Gang Wall Mount*
VAX-CR-35L-OSDP • •
VAX-CSR-6.2-OSDP •
*Plastic or metal
3.0 Cable Requirements
Cable, 4 conductor, 22 or 24 AWG [65 mm or 51 mm] twisted pair,
over-all shield and UL approved (Belden 8273, or equivalent).
Maximum bus length: 4,000 ft – 24 AWG (1,219 m)
Maximum distance between: 1,640 ft – 24 AWG (500 m)
4.0 Reader Wiring
OSDP
Twisted Pair Conductor Function
Pair 1 Red DC (8-14 VDC)
Black Ground
Pair 2 Green RS-485 Tx+
White RS-485 Tx-
5.0 Output Formats
The SIA standard OSDP protocol is supported for clear and secure
channel communication.
Default Address: 0
Default Baud rate: 9600bps (bits per second)
Default Secure Channel Key:
SCBK_D = 0x303132333435363738393A3B3C3D3E3F.
OSDP Protocol Technical Support:
SIA OSDP Application Profile: Basic Reader (OSDP v2.2 and higher)
6.0 Grounding
Shield (drain) continuity must run from the reader to the access panel.
Shield (drain) and reader ground must be tied together at the access
panel and connect to an earth ground at one point.
7.0 Power
Reader may be powered by the access panel. A linear power supply is
recommended for best operation.
8.0 Voltage and Current
Voltage: 8 to 14 VDC
Current Draw: 60mA typical, 250mA peak
9.0 Read Mode
Reader (OSDP “PD”) operation is controlled by the access panel
(OSDP “ACU”) per the OSDP specification.
10.0 Connection
Connection must be done in accordance with NFPA 70. Do not
connect to a receptacle controlled by a switch. Connect to a power
limited DC voltage source.
11.0 Troubleshooting
1. When the reader is first powered on it will beep 4-times, and the
LED will shine red.
2. Presenting a supported access credential will result in the reader
beeping and the LED flashing once.
3. Mobile operation is optimized for smartphones supporting BLE
(Bluetooth LE) version 4.2 or newer. Further, for the downloading of
mobile access credentials, a stable, high-quality internet
connection is recommended.
4. OSDP communications with the panel will be established after the
reader has completed its start-up sequence. The panel can query
the reader for status using OSDP commands. Note, at this point,
the access panel controls the reader beeper and LED functionality.
If the reader does not recognize the card or tag (no beep, no LED
flash), refer to possibe OSDP communications errors detected at the
access control panel. Please see the table on reverse side for
additional possible causes and solutions.
Quick Installation Guide
VAX-CR-35L-OSDP and VAX-CSR-6.2-OSDP
Mobile-Ready Contactless Smartcard Readers with OSDP Support
XX274-31

Possible Cause Corrective Action
OSDP misconfiguration,
not configured for OSDP,
secure channel mismatch
Confirm panel is configured for
OSDP. Confirm panel and reader are
both configured for Secure Channel
(or both unencrypted.) Confirm PD
address and speed.
Incorrect cabling Verify gauge, connections and
cabling length
Not enough power 12 VDC recommended
Incorrect credential used Verify if credential technology
is supported
Reader/access panel not
properly grounded
Earth ground needed—verify shield
and reader ground are tied at access
panel and connect to ground at
one point
Supply generating
interference
Linear power supply recommended,
verify switching power supply
before use
Should any of the corrective actions mentioned above not improve
performance, disconnect the reader from the access panel and power
it with a separate power supply or 9VDC battery, and re-test card
functionality, with an OSDP panel simulator if necessary. By powering
the readers separately, most variables that may lead to reduced
performance can be eliminated. OSDP issues often require a packet
trace, which the installer or panel vendor should be prepared to
provide if there are problems. Should the problem persist, please
contact Vicon Technical Support.
Operating Temperature: –31° F to +150° F (–35° C to +66° C)
Operating Humidity: 0% to 90% Relative Humidity
IP Rating: IP67
Many Vicon Readers carry the following certifications:
FCC Compliance Statement: This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by Farpointe Data could
void the user's authority to operate the equipment.
Product can be used without license conditions or restrictions in all European Union
countries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain,
Sweden, United Kingdom, as well as other non-EU countries, including Iceland,
Norway, and Switzerland.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions: (1) This device may not cause
interference. (2) This device must accept any interference, including interference that
may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est
conforme aux CNR d’Innovation, Sciences et Développement économique Canada
applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage; (2)
L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
For proper PIN security with keypad readers, please review our
PIN Best Practices Reference Document.
QUICK START GUIDE
VAX-CR-35L-OSDP AND VAX-CSR-6.2-OSDP
MOBILE-READY CONTACTLESS SMARTCARD
READERS WITH OSDP SUPPORT
©2021 Vicon Industries. All rights reserved. Vicon and its logo are registered
U.S. trademarks and VAX and its logo are trademarks of Vicon Industries Inc.
All other trademarks are the property of their respective owners.
www.vicon-security.com
P/N: 8009-8274-31-00
Vicon Industries Inc.
Tel: 631-952-2288
Toll Free: 800-645-9116
Fax: 631-951-2288
24-Hour Technical Support:
800-34-VICON (800-348-4266)
UK: 44/(0) 1489-566300
Product specifications are subject to
change without notice.
REV June 2021
This manual suits for next models
1