2.2 Installing the V1600WM Wall Mount
NOTE:
Use stainless steel hardware for all
out-
NOTE:
Never use lag screws in the end grain of
door installations. wood.
Bolts or screws should preferably extend through the
structure with nuts and washers used on the opposite
side. If the mount must be attached to a blind structure
with no access to the rear, make certain that the fasteners
or studs used have a minimum pull-out strength of 400
pounds each. Studs should be either anchored in concrete
or welded to steel.
To install the
V16OOWM,
secure the aluminum base to
the wall surface with four (4) l/4-inch (0.635 cm) lag
screws or machine screws with appropriate nuts and
washers. A knockout cable port is provided for cabling.
See Figure 1 for mounting dimensions.
2.3 Installing the V1600AH
The
V1600AH
consists of three parts, the base, the
platform, and the clamp, plus related hardware. Note the
relationship of the base, clamp, and platform before
removing the hex bolt for installation. The stainless steel
l/4-20 hex bolt,
l/4-inch
washer, and the l/4-20 nut are
required to install the
V1600AH
on the
V1600WM.
Some units are packed with a corrugated cardboard piece
which holds the parts in proper relationship during
shipping. Remove this cardboard and discard it. Refer
to Figures 2 and 3 throughout the following procedure.
1.
Place the round edge of the V1600AH base onto the
mounting platform of the
V1600WM.
2.
Insert the clamp diagonally (with flat side facing up)
inside the
V1600AH
mounting plate. Position the
clamp horizontally and lower it until it rests on the
rounded edges of the mounting plate.
3. Place the
V1600AH
mounting plate with the in-
serted clamp onto the
V1600AH
base. Slide the
washer onto the
l/4-20
hex bolt and insert the
threaded end into the bottom of the
V1600WM,
upwards through the hole in the center of the mount.
Place the hex nut on the bolt at the top of the clamp
and hand tighten, followed by an additional turn to
lock. Make sure the nut is recessed in the hexagonal
recess in the center of the clamping piece.
CAUTION:
Further tightening could damage the
A
unit. Overtightening is not necessary
4.
To position the adjustable head, loosen the hex bolt
on the bottom of the mount, adjust the head to the
desired position, and retighten the bolt.
This completes the installation of the
V1600WM
and
V1600AH.
3. MAINTENANCE
The
V16OOWM
does not require any maintenance.
2
x457-997