V9360W Hemispheric Camera with Advanced WDR
Hardware User’s Manual
-Digital Input (2) - An alarm input for connecting devices that can toggle between an open
and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. The
device will detect the change in digital input and transmit the signal to video surveillance
servers.
Pin 1 GND Ground. Connect with Pin 3 for DI control loop.
Pin 2 12 V Provides power to external devices with a
maximum current of 100 mA.
Voltage: 12 VDC,
Max: 1.2 W
Pin 3 Digital Input 1 Connect to GND (Pin 1) to activate or leave
floating (unconnected) to deactivate.
Must not be exposed
to voltages greater
than 30 VDC.
Pin 4 Digital
Output 1
Connect to Pin 2 through external devices for
DO loop. If used with an external relay, a diode
must be connected in parallel with the load for
protection against transient voltages.
Max load = <100 mA
Max voltage = 24 VDC
(to the transistor)
Pin 5 GND Ground. Connect with Pin 7 for DI control loop.
Pin 6 12 V Provides power to external devices with a
maximum current of 100 mA.
Voltage: 12 VDC,
Max: 1.2 W
Pin 7 Digital Input 2 Connect to GND (Pin 5) to activate or leave
floating (unconnected) to deactivate.
Must not be exposed
to voltages greater
than 30 VDC.
Pin 8 Digital
Output 2
Connect to Pin 6 through external devices for
DO loop. If used with an external relay, a diode
must be connected in parallel with the load for
protection against transient voltages.
Max load = <100 mA
Max voltage = 24 VDC
(to the transistor)
Connect input/output devices to the camera as follows:
1. Attach the cables for the device securely to the supplied green connector block.
2. Once cables are connected, push connector block into the terminal connector on camera.
Digital Input/Output Connector
7) Micro SDHC Card Slot*
Insert a Micro SDHC card (*customer supplied) for local recording on camera.
9