Before you begin:
Installation:
Guarantee & Aftercare:
1.
1.
2.
2.
3.
4.
3.
4.
5.
6.
7.
8.
9.
10.
We recommend that this product is installed by a qualified tradesperson
and we accept no liability for products fitted incorrectly, and where the correct
testing procedures have not been used, resulting in the escape of water.
Observe all local plumbing and building codes.
Unpack the product then read these instructions before proceeding. Inspect the
product for damage. If any damage is found, contact our Customer Relations
team.
Make sure that the two G1/2 male connectors are pre-installed under the floor.
Prepare a circular hole in the floor 100mm (4”) minimum, 150mm (6”) maximum,
75mm (3”) deep.
Decorate the floor. (Pay attention to the size of the holes.)
Unscrew and take o lock nut (3), push decorative cover (1) onto the lower
position of tube (2), then screw the lock nut (3) on to the thread as far as it will
go.
Screw the mounting flange (4) onto the tube.
Tighten screw the lock nut (3) on to the mounting flange (4).
Connect cold / hot inlet pipe (7) to two G1/2 male connectors, which is water
supply pipe.
Use screws (5) and expansion screws (6) to fix Flange (4) to the floor.
Push the decorative cover (1) onto the floor.
Screw Outlet pipe (8) to Tube (2), tighten Round Screw nut (9) by hand (Note;
make sure the two plastic washers (10) are in place).
Fit the hose (15) to the outlet pipe,and the handset (12) to the hose, ensuring
sealing washers (13) are in place.
Open the hot and cold water supply, check all the joints and connections for any
leakage before use.
When installing or using tools, extra care must be taken to avoid damaging
the finish or fitting. To maintain the appearance, please ensure it is cleaned
regularly using a clean soft damp cloth only. Abrasive cleaners or detergents
must not be used as they may cause surface deterioration. The company
provides a guarantee against faulty material or manufacture excluding
serviceable parts, providing they have been installed, cared for and used in
accordance with our instructions.
When the water pressure is lower
than 0.7 bar, no water comes out of
from hand shower, pull out and twist
the knob to lock it in position. After
shower, twist the knob, it will then
reset automatically.