manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Victron energy
  6. •
  7. Measuring Instrument
  8. •
  9. Victron energy BMV-712 User manual

Victron energy BMV-712 User manual

Other manuals for BMV-712

1

This manual suits for next models

2

Other Victron energy Measuring Instrument manuals

Victron energy BMV-700 User manual

Victron energy

Victron energy BMV-700 User manual

Victron energy BMV-600S User manual

Victron energy

Victron energy BMV-600S User manual

Victron energy EM24 User manual

Victron energy

Victron energy EM24 User manual

Victron energy BMV-710H User manual

Victron energy

Victron energy BMV-710H User manual

Victron energy BMV-700 User manual

Victron energy

Victron energy BMV-700 User manual

Victron energy SmartShunt User manual

Victron energy

Victron energy SmartShunt User manual

Victron energy BMV-600 User manual

Victron energy

Victron energy BMV-600 User manual

Victron energy BMV-702 User manual

Victron energy

Victron energy BMV-702 User manual

Victron energy ET340 User manual

Victron energy

Victron energy ET340 User manual

Victron energy BMV-700H User manual

Victron energy

Victron energy BMV-700H User manual

Victron energy Venus GX User manual

Victron energy

Victron energy Venus GX User manual

Victron energy SmartShunt 500A User manual

Victron energy

Victron energy SmartShunt 500A User manual

Victron energy BMV-501 User manual

Victron energy

Victron energy BMV-501 User manual

Victron energy BMV-712 User manual

Victron energy

Victron energy BMV-712 User manual

Victron energy VM-3P75CT User manual

Victron energy

Victron energy VM-3P75CT User manual

Victron energy SmartShunt User manual

Victron energy

Victron energy SmartShunt User manual

Victron energy BMV-700 User manual

Victron energy

Victron energy BMV-700 User manual

Victron energy BMV-600 User manual

Victron energy

Victron energy BMV-600 User manual

Victron energy BMV-700 User manual

Victron energy

Victron energy BMV-700 User manual

Victron energy SmartShunt SHU050150050 User manual

Victron energy

Victron energy SmartShunt SHU050150050 User manual

Victron energy ET112 User manual

Victron energy

Victron energy ET112 User manual

Victron energy EM24 User manual

Victron energy

Victron energy EM24 User manual

Victron energy ABB B21 User manual

Victron energy

Victron energy ABB B21 User manual

Victron energy BMV-600HS User manual

Victron energy

Victron energy BMV-600HS User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

quick installation guide
Battery monitor
2 3
2 3
4 5
Method B
Method A
BMV-700 & BMV-702
Ø 52-53 mm
52 mm
62,4 mm
31 mm
1
7
FIRST TIMERS
In case of Li-Ion batteries, several
settings may have to be changed after
the setup wizard is completed.
Please refer to the manual.
The BMV will automatically adjust itself
to the nominal voltage of commonly
used battery systems.
Please refer to the manual.
WARNING
Please read this guide carefully to avoid
incorrect connections that can cause the
battery monitor to malfunction and/or create
CſTGJC\CTF
Disconnect the negative pole of the battery
before installation.
V2.0 01-01-2014
Wiring diagrams Connect the negative pole of the battery last!
quick installation guide
BMV-702 congured for STARTER/AUXILIARY-battery monitoring.
BMV-700
BMV-702 congured for battery TEMPERATURE monitoring
Fig. 3
Fig. 4
to battery to load
7
Connect the negative pole of the battery last!
+B2
+B1
UTP
Fig. 1 Fig. 2
+
-
-
-
-
+
-
+
-
+
-
+
+
+
+
+
+
+
+
-
-
-
-
+
-
-
-
+
+
+
Always use busbars when applying midpoint voltage monitoring!
Cables to busbars must all have the same length!
+
+
+
-
+
-
-
Connecting multiple batteries without midpoint voltage monitoring : 24 V
+
+
+
-
+
-
+
-
+
-
+
-
-
-
Applying midpoint voltage monitoring : 24 V
OK WRONG
Due to voltage drop over the + and - cables
midpoint voltages are not identical
Shunt
BMV 702
UTP
+B2
+B1
Fig. 5 Fig. 6
Fig. 7 Fig. 8
GOOD
+
+
+
-
-
-
-
-
-
Midpoints should not be interconnected: one bad
battery can go unnoticed and could damage all
other batteries
Midpoints can be interconnected if corrective action
is taken in case of an alarm.
In case of one string of 2 batteries +B1 and +B2 can
be connected directly to the battery posts.
This cable should be short. Voltage drop over this
cable will distort the midpoint measurement.
V2.0 01-01-2014
-
+
-
+ +
-
+
-
+ +
-
+
-
+ +
+
-
+
-
+
-
+
-
-
-
-
Always use busbars when applying midpoint voltage monitoring!
Cables to busbars must all have the same length!
-
Connecting multiple batteries without midpoint voltage monitoring : 48 V
Applying midpoint voltage monitoring : 48 V
OK WRONG
Due to voltage drop over the + and - cables
midpoint voltages are not identical
Shunt
BMV 702
UTP
+B2
+B1
Fig. 9 Fig. 10
Fig. 11 Fig. 12
Midpoints should not be interconnected: one bad
battery can go unnoticed and could damage all
other batteries
Midpoints can be interconnected if corrective action
is taken in case of an alarm.
In case of one string of 4 batteries +B1 and +B2 can
be connected directly to the battery posts.
-
+
-
+ +
-
+
-
+ +
-
+
-
+ +
+
+
-
+
-
+
-
+
-
-
+
-
+ +
-
+
-
+ +
-
+
-
+ +
-
-
-
-
+
-
+ +
-
+
-
+ +
-
+
-
+ +
+
-
+
-
+
-
+
-
-
-
-
+
-
+
-
+
-
+
-
+
-
-
-
-
GOOD
This cable should be short. Voltage drop over this