About this manual
Dimensions : inch (mm)
INSTRUCTION MANUAL XX166-02
Before installing and using the camera, please read this manual carefully.
Be sure to keep it handy for later reference.
This installation should be made by a qualified service person and should
conform to the National Electric Code, ANSI/NFPA 70 and all local codes.
Installers should use appropriate hardware mounting materials.
PRECAUTIONS
■Do not open or modify
Do not open the case except during maintenance and
installation, as it may be dangerous and cause damages.
■Do not put objects inside the unit
Make sure that no metal objects or flammable substances
get inside the camera. It could cause fire, short-circuits or damages.
■Be careful when handling the unit
To prevent damage, do not drop the camera or subject
it to strong shock or vibration.
■Install away from electric or magnetic fields
■Protect from humidity and dust
■Protect from high temperature
Be careful when installing close to the ceiling , in a kitchen
or boiler room, as the temperature may rise to high levels.
■Cleaning
Dirt can be removed from the case only by wiping it
with a soft cloth moistened with a soft detergent solution.
■Mounting Surface
The mounting surface material must be strong enough to support the
camera.

TROUBLESHOOTING
LENS ADJUSTMENT
Before sending the camera out for repair, check the items below.
If the problem persists after checking these items, contact
your service center.
■If no image appears
Is the coaxial cable attached securely?
Are the power and voltage normal?
Has the iris of the lens inside the camera been
adjusted correctly (with the level volume) ?
Is there adequate illumination?
■If the image is unclear
Is the lens in focus?
Is the lens dirty?
Dirt or fingerprints on the lens can adversely affect the
images. Gently wipe any dirt or fingerprints off the lens
with a soft cloth or lens cleaning paper and cleaning
fluid (commercially available).
Is the monitor adjusted correctly?
WARNING:
TO PREVENT THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR
MOISTURE.
1. Adjust the panning(360˚) and tilt(60˚) position.
2. Set the zoom position by using Zoom Lever Screw.
3. Set the focus by using Focus Lever Screw.
4. Loosen set screws to adjust roll (turns camera position top/bottom).
PAN - 360˚
TILT - 60˚
Zoom
Focus
Set Screw
(2x)
ROLL

SPECIFICATION - VC-600, VC-600S
SPECIFICATION - VC-610, VC-610S
GENERAL Spec NTSC PAL
HQ Interline Transfer CCD 1/3" 410K Pixels Color 1/3" 470K Pixels Color
Total Number of Pixels 811(H) x 508(V) 795(H) x 596(V)
Scanning System 525 Lines 625 Lines
Horizontal Resolution
Sensitivity to Light [30IRE]
Gamma Correction
Shutter Speed 1/60 - 1/100,000[NTSC] 1/50 - 1/100,000[PAL]
S/N Ratio
Synchronization
Video Output
Control DIP Switch
BLC
ME/AE
ATW/AWB
AGC
Electrical Spec
Operating Voltage
Power Consumption
Mechanical Spec
Operation Temp
Air Humidity
Lens Mount
Connections via
550TV Lines
0.03fc, 0.3Lux(Scene) With F1.2 Lens
0.45
> 48dB [AGC off]
Internal (12VDC) / External (Line Lock, 24VAC)
1.0Vp-p/75ohm Composite
DIP Switch Select ON/OFF
DIP Switch Select ME/AE (ON/OFF)
DIP Switch Select ON/OFF
12VDC(11-20V), 24VAC(20-27V)
12VDC -2.3W, 24VAC - 2.6W
DIP Switch Select ATW/AWB (ON/OFF)
14°F ~ 131°F ( -10°C ~ +55°C )
Up to max.90%
3.3-12mm
BNC(VIDEO), 2P WIRE(Power)
GENERAL Spec NTSC PAL
CCD Type 1/3" 410K Pixels Color 1/3" 470K Pixels Color
Total Number of Pixels 811(H) x 508(V) 795(H) x 596(V)
Scanning System 525 Lines 625 Lines
Horizontal Resolution
Sensitivity to Light [30IRE]
Gamma Correction
Shutter Speed 1/60 - 1/100,000[NTSC] 1/50 - 1/100,000[PAL]
S/N Ratio
Synchronization
Video Output
Control DIP Switch
ME/AE
ATW/AWB
WDR ON/OFF
AGC MAX ON
Electrical Spec
Operating Voltage
Power Consumption
Mechanical Spec
Operation Temp
Air Humidity
Lens Mount
Connections via
DIP Switch Select ATW/AWB (ON/OFF)
DIP Switch Select ME/AE (ON/OFF)
Up to max.90%
14°F ~ 131°F ( -10°C ~ +55°C )
DIP Switch Select ON/OFF
DIP Switch Select WDR (ON/OFF)
BNC(VIDEO), 2P WIRE(Power)
0.45
0.06fC, 0.6Lux(Scene) With F1.2 Lens
480TV Lines
1.0Vp-p/75ohm Composite
Internal (12VDC) / External (Line Lock, 24VAC)
> 45dB [AGC off]
12VDC -3.9W, 24VAC - 4.0W
12VDC(11-20V), 24VAC(20-27V)
3.3-12mm

■CONNECTIONS
CONNECTIONS AND CAMERA SETTINGS
CAUTION
The use of a UL Listed Class 2 power supply is required to ensure
compliance with electrical safety standards.
Check for polarity when using a 12VDC power supply.
Red (+)
Black (-)
DC12V
AC2 4V
VIDEO

■CAMERA SETTINGS FOR VC-600, VC-600
S
①DIP Switch Functions
(1) Compensating for backlight
ON When backlight is too bright
OFF Normal setting
CAUTION : It will be correctly set by adjusting level volume 5.
(2) Confirming the iris setting
ME(ON) When DC autoiris lens installed
AE(OFF) When fixed iris lens is installed
(3) White balance setting
ATW(ON) Use this under light source below 2500K and
over 9500K of Natrium (Sodium) low
color temperature light
AWB(OFF
)
Use this under light source between 2500K
and 9500K of fluorescent lamp or
incandescent light
(4) Setting gain control (AGC)
For adjusting the sensitivity of the camera.
Use this setting for shooting in dark environments.
ON Normal setting
OFF Set this when there is excessive noise
②Second Video OUT Connector (Option)
If installer is setting with portable monitor, this connector is used.
Be sure to terminate the last video device at 75 ohms.
③IR LED Connector (Option)
If extra IR LED board is attached, this connector is used.
② PORTABLE
MONITOR
③ IR LED ④ LINE LOCK
ADJUSTMENT
⑤ DC LENS
CONTROL
⑥ DC
VARIFOCAL
⑦ POWER
CONNECTOR
①
ON
OFF

④Setting Monitor Synchronization (24 VAC adaptor users)
The camera offers V-phase adjustment over 360°. Vertical
sync disturbance may occur when a switcher is used to switch
between multiple cameras connected to one monitor.
To prevent vertical sync disturbance, adjust ④*.
CAUTION: When using the 12 VDC adaptor, sync setting is
set to internal sync.
⑤Adjusting Level Volume
If the entire image is too dark or bright, or the bakclight
compensation is not correct even after ①is set to "ON",
you need to adjust the level volume.
CCW (LO
W
Closes the lens iris, making the entire image darker
CW (HIGH
)
Opens the lens iris, making the entire image brighter
⑥DC Varifocal Connector
This should be used with ⑤DC IRIS LENS.
⑦Power connector
Connect with AC/DC power, board attached inside.
*Before making any adjustment, confirm that the cameras are
connected to the power supply with the same polarity.
To make an adjustment: While observing the video outputs
from the cameras on an oscilloscope, press the first
camera's V-phase pushbutton. Until vertical sync from
all cameras are in phase. If the first camera's adjustment phase
is insufficient, adjust the second camera's V-phase
contol in the oppposite direction until they are in phase.
■CAMERA SETTINGS FOR VC-610, VC-610
S
OFF ON
1 AE/ME AE ME
2ATW/AWBAWBATW
3 WDR OFF ON
4 AGC MAX OFF ON
NO FUNCTION DIP S/W
⑤ DC LENS
CONTROL
④ LINE LOCK
ADJUSTMENT
② PORTABLE
MONITOR
⑥ DC
VARIFOCAL
⑦ POWER
CONNECTOR
③ IR LED
①

①DIP Switch Functions
(1) Confirming the iris setting
ME(ON) When DC autoiris lens installed
AE(OFF) When fixed iris lens is installed
(2) White balance setting
ATW(ON) Use this under light source below 2500K and
over 9500K of Natrium (Sodium) low
color temperature light
AWB(OFF
)
Use this under light source between 2500K
and 9500K of fluorescent lamp or
incandescent light
(3) WDR mode
ON Wide dynamic function is working
OFF Wide dynamic function is not working
(4) Setting gain control (AGC)
For adjusting the sensitivity of the camera.
Use this setting for shooting in dark environments.
ON Normal setting
OFF Set this when there is excessive noise
②Second Video OUT Connector (Option)
If installer is setting with portable monitor, this connector is used.
Be sure to terminate the last video device at 75 ohms.
③IR LED Connector (Option)
If extra IR LED board is attached, this connector is used.
④Setting Monitor Synchronization (24 VAC adaptor users)
The camera offers V-phase adjustment over 360°. Vertical
sync disturbance may occur when a switcher is used to switch
between multiple cameras connected to one monitor.
To prevent vertical sync disturbance, adjust ④*.
CAUTION: When using the 12 VDC adaptor, sync setting is
set to internal sync.
⑤Adjusting Level Volume
If the entire image is too dark or bright, or the bakclight
compensation is not correct even after ①is set to "ON",
you need to adjust the level volume.
CCW (LO
W
Closes the lens iris, making the entire image darker
CW (HIGH
)
Opens the lens iris, making the entire image brighter
⑥DC Varifocal Connector
This should be used with ⑤DC IRIS LENS.
⑦Power connector
Connect with AC/DC power, board attached inside.

*Before making any adjustment, confirm that the cameras are
connected to the power supply with the same polarity.
To make an adjustment: While observing the video outputs
from the cameras on an oscilloscope, press the first
camera's V-phase pushbutton. Until vertical sync from all cameras
are in phase. If the first camera's adjustment phase
is insufficient, adjust the second camera's V-phase contol
in the oppposite direction until they are in phase.
INSTALLATION
IH
G
F
D
C
A
B
E

The VC-600 and VC-610 can be either mounted to a surface (like
a ceiling or wall) or installed into the ceiling, with or without an
electrical box.
1 Use the philips screwdriver to remove the screw (C).
2 Separate upper case (A) from bottom case (D).
3 For surface mount installations, align the extension
ring (G) with the mounting surface; mark the mounting
screw holes and then drill the four holes. For in-ceiling
installations not mounting to a 4x4 electrical box,
mark the holes in the camera assembly (D) and then
drill the holes. For in-ceiling installations, (G) is not
used.
4 For in-ceiling installations, cut a hole (diameter:
2.9in./73mm) in the ceiling for outing the cables.
5 Route the power cable(s) and video cable(s) to the
installation location.
6 Align the four screw holes in the extension ring (G)
with the screw holes in the ceiling, and then secure
by tightening four screws (F). Secure the camera
assembly (D) in place with screws (F) supplied with
the unit. For in-ceiling installations, align the holes in
(D) with the holes drilled in the ceiling and secure the
camera assembly with the hardware provided. If
installing to an electrical box, secure (D) with the
screws provided.
7 Pass the power cable (I) and video cable (H) from the
camera unit through the cable hole in the ceiling.
8 Carry out the settings and adjustments to the camera.
9 Adjust the dome liner (E) so that the dome camera's
lens is visible from the camera window and then
use a philips screwdriver to attach the dome cover.
10 Connect upper case (A) and bottom case (D).
11 Tighten the screw (C).
INSTALLATION WITH ADAPTER PLATE
1. Install Adapter Plate to existing electrical box in ceiling using 2 8-32 screws.
2. Remove the extension ring from the housing. It is not needed for this
installation.
3. Perform steps 2 and 5-11 from above procedure.

Internet Address: www.vicon-cctv.com
Vicon Industries Inc.
Corporate Headquarters
89 Arkay Drive
Hauppauge, New York 11788
USA
631-952-CCTV (2288)
800-645-9116
Fax: 631-951-CCTV (2288)
European Headquarters
Brunel Way
Fareham, PO15 5TX
United Kingdom
+44(0) 1489 566300
Fax: +44(0) 1489 566322
Vicon Part Number 8009-8166-02-01 Rev 408
Germany
vin-videotronic infosystems
gmbh
Lahnstrasse
D-24539 Neumuenster
Phone: +49 (0) 4321 8790
Fax: +49 (0) 4321 879 47
Far East Office
Unit 5, 17/F, Metropole Square
2 On Yiu Street, Shatin
New Territories,
Hong Kong
(852) 2145-7118
Fax: (852) 2145-7117
This manual suits for next models
3
Table of contents