manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ViM
  6. •
  7. Controllers
  8. •
  9. ViM JBRB ECOWATT User manual

ViM JBRB ECOWATT User manual

Other manuals for JBRB ECOWATT

1

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NT00000712-JBRB-KIT-MONTAGE-VENTIDRIVE-AN-210409
INSTRUCTION MANUAL
INSTALLATION | WIRING | COMMISSIONING | MAINTENANCE |
AFNOR CERTIFICATION
ISO 14001
Environnement
AFNOR CERTIFICATION
ISO 9001
Qualité
JBRB ECOWATT®
Replacing COMPACTO/INVENTO controllers
by a VENTIDRIVE controller
COMPOSITION OF THE JBRB ECOWATT® KIT
VENTIDRIVE controller and INTZ
proximity switch mounted on their
bracket.
Pressure pipes Cable 5x1 mm²
2 collars 2 sheet metal screws
6.2x15
Instruction manual NT00000704-JBRB-ECOWATT-AN
TOOLS NEEDED
-Torx screwdriverT20
-Flat screwdriver 2,5 mm
-PZ2 screwdriver
-13" spanner
-15 mm spanner
JBRB ECOWATT®
with COMPACTO/INVENTO controller JBRB ECOWATT®
with VENTIDRIVE controller
GENERALS
When the original DOMEL controller is no longer functional, it
must be replaced by the KIT supplied.This document describes the
operations to be carried out.
Before any intervention, switch o the power supply to the
unit.
JBRB ECOWATT®CODES DESIGNATION
30 Mono 263970 DOMEL-OJ JBRB 30 Mono controller repla-
cement kit
30 Tri 263971 DOMEL-OJ JBRB 30 Tri controller replace-
ment kit
38 Mono 263972 DOMEL-OJ JBRB 38 Mono controller repla-
cement kit
38 Tri 263973 DOMEL-OJ JBRB 38 Tri controller replace-
ment kit
48 Mono 263974 DOMEL-OJ JBRB 48 Mono controller repla-
cement kit
48 Tri 263975 DOMEL-OJ JBRB 48 Tri controller replace-
ment kit
70 Mono 263976 DOMEL-OJ JBRB 70 Mono controller repla-
cement kit
70 Tri 263977 DOMEL-OJ JBRB 70 Tri controller replace-
ment kit
82 Mono 263978 DOMEL-OJ JBRB 82 Mono controller repla-
cement kit
92 Tri 263979 DOMEL-OJ JBRB 92 Tri controller replace-
ment kit
2/4 NT00000712-JBRB-KIT-MONTAGE-VENTIDRIVE-AN-210409
1REMOVE THE COMPARTMENT
-Open the access door.
-Unscrew the 2 M8x20 screws.
-Remove the roof of the unit by unscrewing the 4 clamps.
Clamps
Roof
Door
Disconnect:
-The power cable from the isolating switch.
-The 2 quick connectors at the bottom right of the compartment.
-The pressure points behind the compartment.
Remove the M8 screw from the bottom of the compartment.
Remove the compartment completely from the unit.
Power supply
Quick connectors
Pressure taps
2DISMANTLE THE REB ECOWATT® AND THE BDEZ
REB ECOWATT® :
-Remove the rotating button by pulling it out.
-Unscrew the nut.
-Remove the cover.
-Unscrew the 2 screws holding the terminal block.
-Unwire.
-Unscrew the 2 screws that hold the box to the metal sheet.
BDEZ :
-Blow out the rivets.
REB ECOWATT®
BDEZ
3MOUNTING AND WIRING REB ECOWATT® AND BDEZ
WITH THE VENTIDRIVE CONTROLLER
Fix REB ECOWATT® :
-Use the 2 sheet metal screws 4.2x16.
Fix BDEZ :
-Use 2 sheet metal screws 6.2x15 supplied.
Wiring
Use the supplied cable to connect the REB ECOWATT® with the
VENTIDRIVE controller.
Pressures tubes
3/4 NT00000712-JBRB-KIT-MONTAGE-VENTIDRIVE-AN-210409
4MOUNT THE NEW COMPARTMENT IN THE PRODUCT
-Recover the 2 male quick connectors from the old compartment.
-Replace the 2 female connectors of the motor cable and the
thermo contact cable by the 2 male ones recovered.
-Respect the following wiring:
PE
U
V
W
PE
U
V
W
4-point female
compartment
connector
5-point female
compartment
connector
4-point male
connector
Motor cable
5-point male
connector
Thermocontact
cable
-Connect the quick connectors.
-Connect the pressure sockets at the back of the compartment, as
shown in the picture below:
-Wire the power supply.
-Close the roof.
-Screw on the door.
5SET UP THE UNIT
Please refer to the instruction manual:
-NT00000704-JBRB-ECOWATT-AN supplied with the kit for
unit setting.
4/4 NT00000712-JBRB-KIT-MONTAGE-VENTIDRIVE-AN-210409
VIM - Les prés de Mégy Sud - SOUDAN - CS 60120 - 79401 ST MAIXENT L’ECOLE CEDEX - FRANCE