manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vimar
  6. •
  7. Network Router
  8. •
  9. Vimar Well-contact Plus User manual

Vimar Well-contact Plus User manual

Other manuals for Well-contact Plus

5

This manual suits for next models

1

Other Vimar Network Router manuals

Vimar WELL-CONTACT PLUS 01506 User manual

Vimar

Vimar WELL-CONTACT PLUS 01506 User manual

Vimar 01506 User guide

Vimar

Vimar 01506 User guide

Vimar 01507 User guide

Vimar

Vimar 01507 User guide

Vimar WELL-CONTACT PLUS 01506 User guide

Vimar

Vimar WELL-CONTACT PLUS 01506 User guide

Vimar WELL-CONTACT PLUS 01506 User manual

Vimar

Vimar WELL-CONTACT PLUS 01506 User manual

Vimar ELVOX TVCC 46260.10P.02 Assembly instructions

Vimar

Vimar ELVOX TVCC 46260.10P.02 Assembly instructions

Popular Network Router manuals by other brands

TRENDnet TEW-435BRM - 54MBPS 802.11G Adsl Firewall M Quick installation guide

TRENDnet

TRENDnet TEW-435BRM - 54MBPS 802.11G Adsl Firewall M Quick installation guide

Siemens SIMOTICS CONNECT 400 manual

Siemens

Siemens SIMOTICS CONNECT 400 manual

Alfa Network ADS-R02 Specifications

Alfa Network

Alfa Network ADS-R02 Specifications

Barracuda Networks Link Balancer quick start guide

Barracuda Networks

Barracuda Networks Link Balancer quick start guide

ZyXEL Communications ES-2024PWR Support notes

ZyXEL Communications

ZyXEL Communications ES-2024PWR Support notes

HPE FlexNetwork 5510 HI Series Openflow configuration guide

HPE

HPE FlexNetwork 5510 HI Series Openflow configuration guide

Allied Telesis AT-AR236E quick start guide

Allied Telesis

Allied Telesis AT-AR236E quick start guide

ADTRAN NetVanta 3458-PoE quick start

ADTRAN

ADTRAN NetVanta 3458-PoE quick start

C&H Technologies EM405-8 manual

C&H Technologies

C&H Technologies EM405-8 manual

Huawei WiFi Mesh 3 Product description

Huawei

Huawei WiFi Mesh 3 Product description

Addonics Technologies ISC8P2G-S Quick install guide

Addonics Technologies

Addonics Technologies ISC8P2G-S Quick install guide

Atel W02 Arch+ Faqs

Atel

Atel W02 Arch+ Faqs

Allnet ALL0333AU user guide

Allnet

Allnet ALL0333AU user guide

Sercomm Genesis OC3505D Quick installation guide

Sercomm

Sercomm Genesis OC3505D Quick installation guide

Billion BIPAC 5102 Series user manual

Billion

Billion BIPAC 5102 Series user manual

TP-Link TD-8817 QIG

TP-Link

TP-Link TD-8817 QIG

Motorola MR1900 user guide

Motorola

Motorola MR1900 user guide

Cisco SOHO Series Regulatory compliance and safety information

Cisco

Cisco SOHO Series Regulatory compliance and safety information

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01507 01 2306
01507
WELL-CONTACT PLUS
By-me KNX IP Router, KNX Secure standard, installation on
DIN rail (60715 TH35), occupies 2 modules size 17.5 mm.
The By-me/KNX router enables communication between parts of a system
comprising By-me devices, grouped together within an “island”, with a system
comprising KNX devices. The messages are transmitted in both directions
according to criteria which define the correspondence of the communication
objects belonging to the specific domains. The router allows up to 500 routing
rules. Each rule is specified by the By-me group address, by the KNX address, by
the direction of communication (from KNX to By-me; from By-me to KNX; both) and
by the type of information exchanged (1 bit, 2 bit, …).
The device is equipped with a TP terminal for connection to the By-me BUS, an
Ethernet connector and a front push button for configuration via ETS. The power
supply is provided by the By-me BUS.
Router 01507 conforms to the KNX Secure requirements on the datapoints defined
in the routing table. A datapoint on the KNX side can be defined for the heartbeat
signal.
CHARACTERISTICS:
• Rated supply voltage: BUS 21- 30 V DC (SELV)
• Max current consumption (on the By-me BUS): <20 mA
• Dissipated power:
- 800 mW average
- 1100 mW maximum
• Operating temperature: - 5°C to + 45°C (indoor use)
• IP20 protection degree
• Protection class III
• Overvoltage category III
• 2 modules of 17.5 mm
CONNECTIONS.
The connection to the bus is made directly from the By-me BUS terminal on the
front of the device. A standard RJ45 connector is available for connection to the
KNX over IP network. The router can be installed inside mounting boxes or panels,
surface mounting or flush mounting with DIN rail (60715 TH35).
CONFIGURATION.
Configuration of the By-me Plus system is carried out using the View Pro App
updated to the latest version (gateway 01410-01411 must be present). On
completion, all the information about the By-me devices can be exported to an
XML file and made available on KNX. The IP KNX Secure router 01548 must be
used to configure the device from one of the tunnelling connections envisaged,
or the IP interface 01547.1 or the USB KNX interface 01540.1 or similar. The
KNX part is configured using the ETS software; a dedicated component, referred to
as a DCA (Device Configuration App), allows you to define the routing rules for the
exchange of messages. The purpose of the DCA is to define the Communication
Objects of the device and allow association of the By-me group address for each
one. Configuration of the KNX group associated with the Communication Object
will be carried out using the standard ETS interface.
The DCA simplifies configuration operations thanks to the copy communication
object function. The copying (cloning) of an entire router is permitted by the
standard ETS functions.
To begin configuring the device and assigning the respective physical address,
press the configuration push button.
All the updated ETS databases can be downloaded from the “Software” section
of the website www.vimar.com.
DEVICE RESET.
Press push button H (LEDs B and C light up) and hold it down for approximately
10 s. When the LEDs are turned off, release the push button and press it again
for approx. 1 s.
INSTALLATION RULES.
• Installation must be carried out by qualified persons in compliance with the
current regulations regarding the installation of electrical equipment in the country
where the products are installed.
• Switch off the power supply before beginning installation.
• Carefully carry out the electrical insulation when making the connections.
• Make sure you keep the 120/230 V lines separate from the SELV conductors.
WEEE - User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life
must be collected separately from other waste. The user must therefore hand the equipment at the end of its
life cycle over to the appropriate municipal centres for the differentiated collection of electrical and electronic
waste. As an alternative to independent management, you can deliver the equipment you want to dispose of
free of charge to the distributor when purchasing a new appliance of an equivalent type. You can also deliver
electronic products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to
electronics distributors with a sales area of at least 400 m2. Proper sorted waste collection for subsequent
recycling, processing and environmentally conscious disposal of the old equipment helps to prevent any
possible negative impact on the environment and human health while promoting the practice of reusing and/
or recycling materials used in manufacture.
CAUTION: Installation of 120/230 V power lines must only be carried out by qualified
persons.
REGULATORY COMPLIANCE.
EMC directive. RoHS directive.
Standards EN IEC 62368-1, EN IEC 61000-6-2, EN IEC 61000-6-3, EN IEC 63044,
EN IEC 63000.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces
of lead.
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01507 01 2306
DESCRIPTION OF LEDS
Green Red
Ethernet KNX over IP line status LED (B)
ON: Correct operation ON: Device factory reset
By-me BUS line status LED (C)
Ethernet KNX over IP line traffic LED (D)
ON: Data traffic presence -
Traffic on By-me BUS line LED (E)
GA LED (F)
-ON: Device not configured
PA LED (G)
Configuration LED (I) - ON: Device in the configuration phase
A: Ethernet KNX over IP line connector
B: Ethernet KNX over IP line status LED
C: By-me BUS line status LED
D: Traffic on Ethernet KNX over IP line LED
E: Traffic on By-me BUS line LED
F: GA LED
G: PA LED
H: Reset push button
I: Configuration LED
L: Configuration push button
M: By-ME BUS line
FRONT VIEW AND CONNECTIONS
01507
ROUTER
IP KNX
IP
State
Traffic
Program
GA
BUS
PA
STP
X
TP
IP