VISIO BW-54-3RGBW IV User manual

15-
Innovation, Quality, Performance
BW-54-3RGBW Ⅳ
User Manual
Please read the instructions carefully before use

1-
14-
5. Troubleshooting
Following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB
of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
6. Fixture Cleaning
The cleaning of internal must be carried out periodically to optimize light output. Cleaning
frequency depends on the environment in which the fixture operates: damp, smoky or
particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s optics.
yClean with soft cloth using normal glass cleaning fluid.
yAlways dry the parts carefully.
yClean the external optics at least every 20 days.

13-
4.4 DMX512 Connection
1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin
adapter-cable.
2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it
in the DMX-output of the last unit.
3. Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to
the input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is
a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded
connectors can easily distort the signal and shut down the system.
4. The DMX output and input connectors are pass-through to maintain the DMX circuit,
when one of the units’ power is disconnected.
5. Each lighting unit needs to have an address set to receive the data sent by the
controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX 512 system should be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin 4/Pin 5:
Not used.
2-
TABLE OF CONTENTS
TABLE OF CONTENTS.............................................................................................2
1. Safety Instructions...........................................................................................................3
2. Techical Specfications ....................................................................................................5
3. How To Set The Fixture ...................................................................................................5
3.1 Control Panel............................................................................................................5
3.2. Main Functions........................................................................................................6
4.How To Control The Unit................................................................................................11
4.1 Master/Slave Built In Preprogrammed Function ................................................11
4.2 DMX Controller.......................................................................................................11
4.3 DMX 512 Configuration .........................................................................................12
4.4 DMX512 Connection..............................................................................................13
5. Troubleshooting.............................................................................................................14
6. Fixture Cleaning.............................................................................................................14

3-
1. Safety Instructions
WARNING
yPlease keep this User Guide for future consultation. If you sell the unit to another user,
be sure that they also receive this instruction booklet.
Caution:
yAll fixtures are intact from the manufacturer, please operate follow up the user manual,
artificial fault are not under guarantee repair.
yUnpack and check carefully there is no transportation damage before using the unit.
yThe unit is for indoor use only. Use only in a dry location.
yDo install and operate by operator.
yUse safety chain when fixes the unit.
yThe unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces.
yBe sure that no ventilation slots are blocked, otherwise the unit will be overheated.
yBefore operating, ensure that the voltage and frequency of power supply match the
power requirements of the unit.
yIt’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
yMaximum ambient temperature TA : 40 . Don’t operate it where the temperature is℃
higher than this.
yDon’t connect the device to any dimmer pack.
yFirst run, there will be smoke or smells, and all disappearing a few minutes later.
yMake sure there are no flammable materials close to the unit while operating, as it is fire
hazard.
yLook over power wires carefully, replace immediately if there is any damage.
yUnit surface temperature may reach up to 60 . Don’t touch the housing bare℃-hand
during its operation.
yNever run on for a long time lest shortening lifespan.
yAvoid any inflammable liquids, water or metal objects entering the unit. Once it happen,
Please read the instructions carefully which include
important information about the installation, operation
and maintenance.
12-
4.3 DMX 512 Configuration

11-
Fixture Hours
Press the MENU button up to when the is blinking on the display. Press ENTER
button and the display will show the number of working hours of the unit. To go back to the
functions press the MENU button.
Software version
Press the MENU button up to when the is blinking on the display. Press ENTER
button and the display will show the version of software of the unit. To go back to the
functions press the MENU button again.
4.How To Control The Unit
You can operate the unit in two ways:
1. By master/slave built-in preprogram function
2. By DMX controller
No need to turn the unit off when you change the DMX address, as new DMX address
setting will be effected at once. Every time you turn the unit on, it will show on the
display and move all the motors to their ‘home’position. After that the unit will be ready to
receive DMX signal or run the built in programs.
4.1 Master/Slave Built In Preprogrammed Function
By linking the units in master/slave connection, the first unit will control the other units to
give an automatic, sound activated, synchronized light show. This function is good when
you want an instant show. You have to select (show 1) or (show 2) ……or
(show 19, show17~19 have to be edited by the user) show for the first unit. Its DMX
input jack will have nothing plugged into. The other units will be slave mode automatically.
4.2 DMX Controller
Use universal DMX controller to control the units, you have to set DMX address from 1 to
512 channel so that the units can receive DMX signal.
Press the MENU button up to when the is showing on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to change the DMX512
address. Once the address has been selected, press and keep ENTER button pressed up
to when the display stops blinking or storing automatically 8 seconds later. To go back to
the functions without any change press the MENU button again.
Please refer to the following diagram to address your DMX512 channel for the first 4 units:
4 Channels:
4D Channels:
4C Channels:
4-
cut off the mains power immediately.
yDo not operate in dirty and dusty environment, also cleaning fixtures regularly.
yDo not allow children to operate the fixture.
yDo not touch any wire during operation as there might be a hazard of electric shock.
yAvoid power wires together arounding other cables.
yReplace fuse only with the same type.
yIn the event of serious operating problem, stop using the unit immediately.
yNever turn on and off the unit time after time.
yThe housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
yDo not open the unit as there are no user serviceable parts inside. Never try to repair
the unit by yourself. Repairs carried out by unskilled people can lead to damage or
malfunction. Please contact the nearest authorized technical assistance center.
yDisconnect the mains power if the fixture is not used for a long time.
yDo use original packing materials once transport it again.
yTo prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
yDo not look directly at the LED light beam while the fixture is on.
yTo protect the machine, power off 10s rear can electrify.
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the
unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the
structure to which you are attaching the unit is secure and is able to support a weight of
10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the
weight of the unit when installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at a place where is
out of the touch of people and has no one pass by or under it.
When the power supply is 110V, do not connect in series much
more than 7 units, use another mains supply for next 7 units. When
the power supply is 230V, do not connect in series much more than
14 units, use another mains supply for next 14 units.

5-
2. Techical Specfications
yLight source: 3W LED x 54pcs
yVoltage: AC 100-240V/50HZ
yPower consumption: 145W
yLens Option: D6,D15,D25,D30,D40,D60,D80
yDimension: 300.6 x 229 x 340 mm
yWeight:9.2 kg
3. How To Set The Fixture
3.1 Control Panel
1: Power
Water proof connectors for power input/output
2: DMX input/output
Water proof connectors for DMX 512 operation, 3-pin XLR cable to link the units together
3: Display
To show the menu and the selected functions
10-
1. If (flash mode)is selected,press ENTER button to confirm, then use DOWN
and UP button to select the (wait time) or (strobe), Once select, press
ENTER button to confirm. then use DOWN and UP button to adjust the the wait time or
strobe speed (solw ,middle, fast) (1…..9). Once select, press ENTER button to store or
automatically return to the main functions without any change after one minute. To go
back to the previous functions without any change press the MENU button.
2. If (flash mode)is selected, press ENTER button to confirm, then use DOWN
and UP button to adjust the type of the rotation(1…..9). Once select ,press ENTER
button to store or automatically return to the main functions without any change after
one minute. To go back to the previous functions without any change press the MENU
button.
3. If (fade)is selected, press ENTER button to confirm, then use DOWN and UP
button to adjust rotation time(1…..9). Once select ,press ENTER button to store or
automatically return to the main functions without any change after one minute. To go
back to the previous functions without any change press the MENU button.
Key Board Lock
Press the MENU button up to when the is showing on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to select the (lock the
key board)或 (normal),Once select, press the ENTER button to setup or
automatically return to the main functions without any change after one minute. Back to the
previous functions press MENU button.
Self-Test
Press the MENU button up to when the,is blinking on the display. Press ENTER
button and the unit will run self-test by built-in program. To go back to the functions press the
MENU button again.
LED
Press the MENU button up to when the is shown on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to select (display on)
or (display off 20 seconds after exit menu)mode. Once select, press ENTER
button to setup or exit menu mode without any change after one minute. Back to the
functions without any change press MENU button again.
Temperature Test
Press the MENU button up to when the is blinking on the display. Press ENTER
button and the display will show the temperature of the unit. To go back to the functions
press the MENU button again.

9-
(color) and (white) and (dimmer) for every step. Automatically return to
the main functions without any change after one minute. To go back to the previous
functions without any change press the MENU button.
Manual Mode
Press the MENU button up to when the is showing on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to select the (Red),
(Green), (White), (Dimmer)or (Shutter),Once select,
press ENTER button to setup or automatically exit menu mode without any change after
one minute. To go back to the functions without any change press the MENU button.
Adjust White Balance
Press the MENU button up to when the is showing on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to select the (Red),
(Green),or (Blue)mode. Once the mode has been selected, press the
ENTER button to setup or automatically return to the main functions without any change
after one minute. To go back to the previous functions without any change press the MENU
button.
Display Inversion
Press the MENU button up to when the is showing on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to select the (normal)
or (inverse),
DMX Control Mode
Press the MENU button up to when the is shown on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to select the (DMX
control)or (manual control),Once selected, press the ENTER button to setup.
If is selected, use DOWN and UP button to select (Flash mode),
(Red), (Green), (Blue), (White), (Yellow),
(Purple), (Cyan), (Whole), (Rotation)or (fade),
press ENTER button to confirm, then use DOWN and UP button to adjust the
dimmer(1…9).
Notice:
1.If (flash mode)is selected,press ENTER button to confirm, then use DOWN and
UP button to select the (wait time) or (shutter), Once select, press ENTER
button to confirm. then use DOWN and UP button to adjust the the wait time or shutter
speed(solw ,midum, fast)(1…..9). Once select, press ENTER button to store or
automatically return to the main functions without any change after one minute. To go back
to the previous functions without any change press the MENU button.
6-
Button:
3.2. Main Functions
To select any functions, press MENU button until the required one is shown on the display.
Select the function by ENTER button and the display will blink. Use DOWN and UP button
to change the mode. Once the required mode has been selected, press ENTER button to
setup or it will automatically return tothe main functions without any change after idling one
minute. Back to the functions without any change press MENU button. The main functions
are shown below:
4 MENU To select the programming functions
5 DOWN To go backward in the selected functions
6 UP To go forward in the selected functions
7 ENTER To confirm the selected functions
Once you set to , after running in show
mode for 5 minutes without any change or
restarting the unit, the key board become locked.
Press ENTER button to enable the menu, the
display will show , press UP and DOWN
button until it shows
,
then
p
ress ENTER to unlock.

7-
8-
DMX 512 Address Setting
Press the MENU button up to when the is shown on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to change the DMX 512
address. Once the address has been selected, press ENTER button to setup or
automatically exit menu mode without any change after one minute. Back to the previous
functions without any change press MENU button.
Channel mode
Press the MENU button up to when the is shown on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to select the
(4channels, (7channels)or (5channels),Once select, press ENTER
button to setup or automatically exit menu mode without any change after one minute. To
go back to the functions without any change press the MENU button.
Show mode
Press the MENU button up to when the is shown on the display. Press ENTER
button and the display will blink. Use DOWN and UP button to select the (show
1)…. (show 19),Once select, press ENTER button to setup. press the ENTER
button,will blinking on the display, use DOWN and UP button adjust the fade time
(0~255), press ENTER button to store and will blinking on the display, use DOWN
and UP button adjust the white time (0~255), press ENTER button to store or automatically
return to the main functions without any change after one minute. To go back to the
previous functions without any change press the MENU button.
Blackout mode
Press the MENU button up to when the is showing on the display, Press ENTER
button and the display will blink. Use DOWN and UP button to select the
(blackout)or (normal),Once select, press ENTER button to setup or
automatically exit menu mode without any change after one minute. To go back to the
functions without any change press the MENU button.
Program Shows
Press the MENU button up to when the is showing on the display. Press ENTER
button and select the mode, Press ENTER button and the display will blink. Use
DOWN and UP button to select the (Show 17), (Show 18)or
(Show 19),Once the show has been selected, press the ENTER button to enter setting
program. Use DOWN and UP button to select (length, the steps, you choose from
the total amount of steps, you want to run, for example, if the total amount of steps you set
is 50, you can choose only first 1-10 steps to run). (step), select to set
Other manuals for BW-54-3RGBW IV
1
Table of contents
Popular Lighting Equipment manuals by other brands

KOZii
KOZii KPACK3G50SRVBCCT instruction manual

Vision & Control
Vision & Control A-DIF-120x240-IR850-SL Instructions for use

Pyroterra Lighttoys
Pyroterra Lighttoys FT2 installation guide

Nice
Nice TTDRGB Instructions and warnings for installation and use

EasyPro
EasyPro Cabrio Lighting Series Instructions for Operation, Safety, Warranty

EuroLite