Visiomed - LX-360 - 122015 Visiomed - LX-360 - 122015
16 17
- Do not touch the infra-red lens with your ngers.
- Clean the glass with a cotton bud dipped in 70% alcohol.
- Do not expose the thermometer to direct sunlight or to water.
- Do not use this thermometer outdoors.
- Never drop the thermometer.
- Do not attempt to repair this thermometer. In the event of a problem, contact your retailer.
- Please keep the thermometer o the children’s touch. Prevent the product from children playing, swal-
lowing and eating.
- The MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs to be installed
and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS.
- Portable and mobile RF communications equipment can aect MEDICAL ELECTRICAL EQUIPMENT.
- The measuring result of this product is only for your reference. If you have any doubt, please measure
the temperature in other methods.
IMPORTANT
Check the batteries are inserted the right way. Reversing the polarity may damage
the thermometer and aect its warranty.
The manufacturer reserves the right to alter the specications of the product without prior notication.
I. INTRODUCTION
The THERMOFLASH® LX-360 is a revolutionary infra-red medical thermometer, tted with cutting edge
MicroSecondFlash™ automatic calibration technology, developed by Visiomed®.
Easy to use, it reads your body temperature from a distance of 5 to 8 cm in less than a second. Fast and accu-
rate, all you have to do is position the ThermoFlash® toward the forehead to instantly see the temperature.
ThermoFlash® is especially eective for taking the temperature of babies and small children. It has been
demonstrated that for new-born children, taking the temperature via the temporal artery is more ac-
curate than taking it aurally, and less distressing than via the rectum*.
ThermoFlash® can be used at any age.
ThermoFlash® can also be used to check the temperature of the bath, food, or ambient temperature.
* Greenes D, Fleisher G. Accuracy of a Non-invasive Temporal Artery Thermometer for Use in Infants. Arch Pediatr
Adolesc Med 2001; 155:376.
II. PRECAUTIONS TO TAKE BEFORE USE
The parameters for the THERMOFLASH® LX-360 are set at the factory. It is not necessary to calibrate the
thermometer during start-up.
In order to guarantee a reliable and stable result, we advise when moving to an environment of a very
dierent temperature, to leave your THERMOFLASH® LX-360 at this ambient temperature for 15-20
minutes before use. Before taking the next temperature, wait for the screen to switch o. You cannot
take a temperature while the screen is lit up.
III. USE
Every solid, liquid or gaseous body emits energy by radiation. The intensity of this energy depends on
the temperature of the object. The infra-red thermometer THERMOFLASH® LX-360 can in this way read
a person’s temperature by the quantity of energy he or she emits. This is possible thanks to the external
temperature probe which constantly analyzes and records the ambient temperature. This means that as
soon as the operator sets the thermometer close to the body and activates the heat sensor, the reading
THERMOFLASH® LX-360 is clinically tested and approved ASTM 1965-1998 (2009).
CONTENTS
I. INTRODUCTION............................................................................................................................................................................................................... 17
II. PRECAUTIONS TO TAKE BEFORE USE............................................................................................................................................................ 17
III. USE...........................................................................................................................................................................................................................................17
different means of reading body temperature ..................................................................................................................................................18
advantages of taking the temporaL artery temperature (ta).....................................................................................................................18
guideLines to foLLow before taking atemperature .........................................................................................................................................18
how to take atemperature.......................................................................................................................................................................................... 19
Constraints .........................................................................................................................................................................................................................19
IV. FUNCTIONS...................................................................................................................................................................................................................... 19
V. DESCRIPTION OF THERMOFLASH® LX-360.............................................................................................................................................. 19
VI. STARTING UP YOUR THERMOFLASH® LX-360......................................................................................................................................19
VII. CONFIGURATION & MENU FUNCTIONS.................................................................................................................................................. 20
1. Choosing how to take the temperature...........................................................................................................................................................20
2. Choosing the temperature unit............................................................................................................................................................................ 20
3. the mem button........................................................................................................................................................................................................ 20
F1 – high temperature aLert setting..............................................................................................................................................................20
F2 – reCaLibration ...................................................................................................................................................................................................20
F3 – add/remove beep............................................................................................................................................................................................ 20
4. the baCkLight button ................................................................................................................................................................................................21
5. exit Configuration mode .........................................................................................................................................................................................21
6. data saving.....................................................................................................................................................................................................................21
7. Changing the batteries............................................................................................................................................................................................. 21
VIII. PRECISION & TECHNICAL CHARACTERISTICS...................................................................................................................................21
Longevity use ......................................................................................................................................................................................................................21
IX. NOTES...................................................................................................................................................................................................................................23
X. ACCESSORIES................................................................................................................................................................................................................... 23
XI. TROUBLESHOOTING.................................................................................................................................................................................................23
GUARANTEE AT THE END OF THE MANUAL
SN
Serial number
Year Month Day Product serial number
SN :
- Follow the maintenance instructions listed in this document.
- This thermometer may be used for personal use at home.
- Only use this thermometer for the prescribed purposes listed in this document.
- Use this thermometer in an ambient temperature between 10°C and 40°C.
- This thermometer must always be stored in a clean, dry place.
- Do not expose this thermometer to electric shocks.
- Do not expose this thermometer to extreme temperature conditions: T° > 50°C, T° < -20°C.
- Do not use this thermometer in an environment with higher than 85% relative humidity.
- The glass protecting the lens is the most fragile part of the thermometer.