P-RHIDBALLAST.50.V
TECHNICAL INFORMATION
Vision X 50 WATT Off Road Ballast & Starter
Washington Office
901 Algona Blvd N.
Unit F
Algona, WA 98001
Ph: 888-489-9820
Fx: 253-218-2905
Arizona Office
6501 E. Greenway
Suite 103-542
Scottsdale, AZ 85254
Ph: 800-994-4460
Fx: 480-922-5655
www.visionxusa.com
Page 2 of 3
4/29/2010
m:\technical data\hid\p-rhidballast.50.v technical specifications.doc
P-RHIDBALLAST.50.V Options
Type Order No. Output/W Lamps
EP8050DC-
USBDF9-P EP8050DC-USBDF9-P 50
Technical data
Input Voltage Range DC9V~32V
Typical Operating Voltage DC12.8V
Typical Operating Voltage DC24V
Typical Input Current 4.3A, Condition: DC 12.8V Input
Typical Input Current 2.2A, Condition: DC 24V Input
Max. Inrush Current 25A
Output Power 47W±2W (Constant Power)
Output voltage AC85V±15V (Square Pulse, RMS70V~100V)
Output Frequency 260Hz~280Hz
Efficiency:≥83%,
Ignition pulse Typical peak Voltage 23kV
Typical duration 1s
Cooling method Natural cooling
Input Protections Under voltage protection at 6V±1V
Over voltage protection at 34.5V±1V
Input connection-reverse protection
Output Protections Short circuit protection between two outputs
Open circuit protection between two outputs
Operating temperature -40℃~+80℃
Storage temperature -40℃~+105℃