visplay Invisible3 User manual

play it smart
Invisible 3
Assembly and operating instructions

2
General Instructions
1/2019 (EN)
EN Visplay products are manufactured according to the
latest technology and comply with valid rules and regu-
lations.
Nevertheless, these products can cause injury or dama-
ge if:
• the product is improperly installed
• the product is improperly used
• the product is improperly altered or modified
• original accessories are not used
• the safety regulations are not observed.
⚠WARNING
Each person involved in the planning, installation
and/or use of our products must be carefully read
and observe these instructions of use.
The following are of course also valid:
• Relevant accident prevention regulations
• Generally recognized safety rules
• National regulations – please consult Visplay if there
is a discrepancy with the Assembly manual
Safety instructions
⚠WARNING
When playing, children often incorrectly assess
danger. You must therefore make sure that your
store fittings are not used as toys.
Please pay attention to the following points:
• Structural conditions, in particular the design and bea-
ring capacity of walls, ceilings and floors. If bearing
capacity for the specified tractive or pressure load
cannot be achieved by suitable fastening or stabilising
elements, please refrain from installation.
• All the structural components supplied for stabilising
structures are to be used in an unrestricted manner
and must not be removed.
• The products may only be loaded after all the installa-
tion steps have been completed.
• Merchandise supports should be loaded as evenly as
possible.
• Avoid loading in fits and starts.
• The maximum weight loads is to be observed. This can
be found in the instructions on assembly and use, as
well as in our sales documentation.
• Furniture with castors is generally much more unstable
than furniture with glides. Tall, heavy structures on
castors should thus be avoided.
• The recommendations of your safety ocer should
also be observed.
General care for chrome, silk and pearl
In clothing retail applications, frequent dragging of clo-
thes hangers along the surface can cause slight abrasion
to their hooks. This eect is most pronounced - more so
than with front-on horizontal or inclined-pole displays
- where garments are hung side-on such that hangers
have to be moved more frequently. To prevent garments
from becoming soiled, cleaning of the hanging rods is
essential.
This abrasion can be considerably reduced by using a
coat hanger cover (scliss, 929-449.02).
No responsiblity can be accepted for damage caused by
soiling, as the above mentioned abrasion depends on the
material of the coathangers in use.
With powder-coated surfaces subject to frequent use,
use of special paints is recommended. We will be happy
to advise you.
Use and care of merchandise supports
with anodised aluminium surfaces
Visplay merchandise supports with anodised aluminium
surfaces are hard-wearing. However, the exchange of
accessories might cause slight marks on the surface.
Accessories with plastic inserts usually cause less wear or
none at all.
To remove the marks, we recommend using cleaning
agents ranging from pH 5–8 (do not use any detergents
with acidic or alkaline reaction). Clean by washing the
surfaces using a sponge and water containing a wetting
agent. Then remove any loose or greasy dirt. Rubbing
o the surfaces with detergent using pure cotton waste
or porous cleaning tissue and applying the necessary
pressure in rubbing direction will remove the marks.
Aluminium profiles with widths exceeding mm must
be subjected to abrasive cleaning using detergents spe-
cifically developed for this purpose. The cleaning agents
developed for abrasive cleaning contain very finely
ground neutral polishing agents and have to be adapted
to the oxide layer. Alternatively, cleaning can be carried
out using an abrasive fibrous web (e.g. Scotch-Brite, type
A, red, fine or very fine) in combination with a non-abra-
sive detergent.
Subsequently, residual cleaning agents should to be
rinsed o using a sponge and clear water. Then rub o
the part with a chamois.

3
Invisible3
27
40
20
ø 3.6
520
100 ±0.5 100 ±0.5
3100 ±1/ lto
0
-0.5
4.2
4.2
(19.25)
(13)
(17.75)
50
1.9
6.1
1.5
3
+0.1
– 0.05
40
14.8 6.3
(3.1)
+0.4
-0.1
0
- 0.2
+0.2
0
8
+0.3
0
R 3.1
+0.2
0
3.7
(12.3)
16
(18.9)
+0.2
0
R 7.4
(A - 6)
(A)
1/2019 (EN)1/2019 (EN)
EN
Examples of fixation
Assembly dimensions / Layout - Invisible profile for mm wooden panel
Rear
Length of groove = length of profile + x +
Length of groove = length of profile + x +
Length of profile
Reinforcement Reinforcement Reinforcement
Substructure
Layout
Panels and sub-structures must be
toughened against bowing. Wooden
ledges or angle sections are suitable for
this purpose.
glued and screwed

4
Invisible3
0
--0,2
16 +0,4
--0,1
1.5
3.7
+0,2
0
+0,2
0
4.7
2.7
3.7
16
(12.3)
4.2 +0,2
0
0
- 0,2
+0,4
-0,1
ABC
33.3 33.3 33.3 29.5
34
0
-0.5
3100 / lto
66.724.4
1.7
231.5
100
0
-0.5
4840.5
22
33.3 29.733.3
117.5
100
18
6.5
25
ø 4.5
150
3100 / lto
1/2019 (EN)
EN Assembly instructions
The following steps must be carried out when assembling the Invisible profile for mm wooden panel:
Screw first profile to the lowest panel from the rear using x mm wood screws - see »A« for edge contour.
Screw pre-mounted panel to substructure from the front. The indicated bore holes must be countersunk in the profile. The profile is screwed to the
substructure using countersunk screws - see »B«.
All further profiles are to be pre-assembled according to steps and fitted to the lower profile and screwed together. See »C« for bottom panel
groove.
Assembled directly onto the wall Assembled onto substructure
e.g. Fixation profile
Invisible3 profiles are available in two dierent versions:
• Single sided (18mm) assembled on wooden panels
• Double sided (34mm) assembled between profile frames (min. 35 mm)
Assembly dimensions / Layout - Invisible profile single sided and double sided
Invisible3 profile double-sided
Invisible3 profile single sided

5
Invisible3
22
122
150
150
Empfehlung: Leiste zur
Abstützung der untersten
Paneelprofilkante
ASenkschraube M5 x 30 mm
BFlachkopfschraube 4 x 5 mm
19
(16)
13.5
Empfehlung:
Alle Befestigungspunkte nutzen,
d.h. alle 150 mm verschrauben
B
Empfehlung: mind. alle
300 mm verschrauben
A
22.4 66.7 33.3 66.7
1/2019 (EN)1/2019 (EN)
EN
Assembly instructions Invisible3 profile panels one-sided
The following steps must be carried out when
assembling a one-sided profile:
1. Screw the lowest profile to the wooden panel
(min. 16mm) from the front using a 4 x 15mm
screw and from the rear using a M5 x 20mm
screw.
2. Insert a profile into the top of the bottom pro-
file - making sure that the profile is correctly
locked into place - and screw to the wooden
panel with 4 x 15mm screw.
3. Insert Invisible3 end profile - making sure
that the profile is securely locked in place.
4. Screw frame to support panel.
Frame
ACountersunk screw M x mm
BPan-head screw x mm
Assembly instructions Invisible3 profile panels double-sided
The following steps must be carried out when assembling
a two-sided profile:
1. Connect double-sided Invisible3 profile panels to one
another - making sure that each profile is securely
locked in place.
2. Fit the end profile at the top - making sure that it is
securely locked in place.
3. Popular frame solutions (e.g. wood) are to be screwed
to the Invisible3 profiles with M5 screws from the side.
Recommendation:
fit screw at least every
mm
Recommendation:
use all fixation points, i.e. fit
screw every mm
Recommendation:
bar to support bottom
profile edge

6
Invisible3
2500
1250
655 640 640
60
1240
1250
900
1540555
450 350350350350350
50
8
3.5 1x45°
0.50.5
15.3
2.2
6.6
1.7
11
6.1
1/2019 (EN)
EN
Weight loading
Invisible3 panel (one-sided)
Panel with aluminium frame, to be attached with fixing set (fixing sets per
panel are required).
Max. load
Profile per mm kg
Profile panels one-sided per mm split over all grooves kg
Profile panels double-sided per mm split over all grooves kg
Front arms Ømm kg
Side hanging frame Ømm kg
Hooks Ømm kg
Hooks Ømm kg
Looped hooks Ømm kg
Glasses holder kg
Clamp bracket for glass shelf per bracket kg
The indicated weight loads are always based on the total weights of the merchandise support and goods.
Please observe that max. weight loading decreases as the merchandise support increases in length.
Please observe that the inclination of the merchandise support changes with an increase in load. Dierent weights on the merchandise
supports produce an uneven overall appearance of the goods display.
The max. weight loading of Invisible3 depends on the nature of the wall, on the number of fixation points as well as on the fixation material
used. All fixation points are to be used with a maximum weight load.
Please also observe the weight loads indicated in our sales documentation.
Instructions of use
The Invisible accessories/shelves are
inserted in to the holders or profile at a slight
angle until the limit stop is reached.
Then lower the accessory/shelf.
Check that the accessory is correctly clicked
into the profile.
Assembly dimensions - Invisible profile double sided for gondolas
Also glue with PUR rigid foam
Table of contents
Other visplay Rack & Stand manuals
Popular Rack & Stand manuals by other brands

CHIEF
CHIEF PSH-2000 installation instructions

Mounting Dream
Mounting Dream MD5402 Installation instruction

NETGEAR
NETGEAR Orbi RBKWMB quick start guide

Olecranon
Olecranon XCLIP Instructions for installation and use

OBERON
OBERON 39-1015-RAB installation guide

ARMAC MARTIN
ARMAC MARTIN Digbeth Hook How to install