INSTALLATION INSTRUCTIONS
Inground & Well Lights
Architectural Series
1162
IMPORTANT NOTE:
• Luminaire must be installed and grounded in accordance with the National Electrical Code (NEC) and local codes.
• All conduit entries must be sealed from moisture. Use appropriate sealing material on conduit fittings and conduit closure plugs.
• Luminaire is wet location listed and suitable for mounting ingrade.
• Suitable for all types of construction including poured concrete construction and in soil applications.
• Suitable for through wiring: max. of (4) No. 12 AWG conductors (plus ground) rated for 90°C.
MAINTENANCE: To assure proper operation and efficiency, lens must be kept clean and free of dirt, dust, leaves, trash and mineral deposits
from water. A regular schedule maintenance program is recommended.
NOTE: Save these instructions for future reference.
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
INGRADE SOIL INSTALLATION:
PRECAUTION: Luminaire is not submersible and adequate drainage
must be provided during installation. It is recommended the luminaire be
surrounded by 3” to 4” of pea gravel or sand to assure proper drainage.
Top of luminaire must be above grade so rain and irrigation water will not
accumulate for long periods of time.
1. To prevent electrical shock, turn main power off at circuit breaker.
2. Dig hole approximately 10” in diameter to a depth suitable to make top
of temporary cover plate ¾” above grade (see fig. 1). Pea gravel or sand
is recommended for seating the luminaire housing.
3. Connect conduit to housing. UL listed flexible conduit is recommended
for in and out connections to ease fixture positioning.
4. Plug any unused NPT holes with closure plugs (provided).
5. Position fixture within hole and back-fill with pea gravel or sand.
6. Pull electrical supply wires (line in) through conduit and luminaire. Pull
wires and make a 6” loop, long enough for manual connections with
safety connectors (4” to 6” above the top rim of luminaire).
CONCRETE POUR INSTALLATION:
IMPORTANT NOTE: Temporary cover plate (purchased seperately) and
vinyl label must remain in place during housing installation.
PRECAUTION: Vinyl label and top of temporary cover plate must be at
finished grade.
1. To prevent electrical shock, turn main power off at circuit breaker.
2. Dig hole approximately 10” in diameter to a depth suitable to make top
of fixture flush grade (see fig. 2). Pea gravel or sand is recommended for
seating the luminaire housing.
3. Connect conduit to housing. UL listed flexible conduit is recommended
for in and out connections to ease fixture positioning.
4. Plug any unused NPT holes with closure plugs (provided).
5. Position fixture within hole and back-fill with pea gravel or sand.
6. To keep housing from floating, affix to rebar or grid-wire using standard
masonry methods.
7. Pour concrete at least 2” thick. Trowel concrete so that it is even with
vinyl label. Allow concrete to cure.
8. To pull supply conductor wiring, remove and retain vinyl label and
temporary cover plate.
9. Pull electrical supply wires (line-in) through conduit and luminaire. Pull
wires and make a 6” loop, long enough for manual connections with
safety connectors (4” to 6” above the top rim of luminaire).
10. Stuff wire loop into housing and reinstall temporary cover plate and
vinyl label.
FIXTURE COVER
FIXTURE HOUSING
GRAVEL/SAND
SOIL
FLEXIBLE CONDUIT
(RECOMMENDED)
RIGID CONDUIT
Figure 1
TEMPORY COVER PLATE/VINYL LABEL
FIXTURE HOUSING
CONCRETE
RIGID CONDUIT
FLEXIBLE CONDUIT
(RECOMMENDED)
CPF1 (Concrete Pour Form)
(Purchased Seperately)
Figure 2
VINYL LABEL
SCREWS
CPF-1
1164 HOUSING
COVER SCREWS
FIXTURE COVER
CONVEX LENS
SILICONE O-RING
(UPPER)
FIELD REPLACEABLE
LED ENGINE
FIXTURE HOUSING
FIELD REPLACEABLE
LED DRIVER
SILICONE O-RING
(LOWER)
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
1162 (08/12)
SILICONE FILLED WIRE NUT,
CONNECT SUPPLY TO
LOAD CONDUCTORS
LOAD CONDUCTORS
LINE: BLACK
NEUTRAL: WHITE
GROUND: GREEN
SILICONE O-RING
(LOWER)
REPLACEABLE
LED ENGINE
SUPPLY CONDUCTORS
LINE, NEUTRAL, GROUND
IMPORTANT NOTE:
DO NOT FILL SEALANT
ABOVE THIS BOSS SURFACE
HOUSING
SEALANT
RE-ENTERABLE
DUCT SEAL DUCT SEAL
LED ENGINE AND FIXTURE COVER INSTALLATION:
1. To prevent electrical shock, turn main power off at circuit breaker.
2. Remove vinyl label and temporary cover plate (if used).
3. Pull supply conductor wire loop out of housing, cut at center and strip
leads. Place lower silicone O-ring onto fixture housing (see fig. 3).
4. Using the silicone filled wirenuts (provided), connect the load conductors
of the replaceable LED engine to the supply conductors (see fig. 3).
INSTRUCTIONS FOR SEALING WIRING COMPARTMENT:
NOTE: Failure to properly wire and encapsulate wire compartment will
void product warranty.
5. Use Mastic (provided), to seal the conduit entries from inside wire
compartment to ensure the sealant (see below) does not flow down into
the conduit.
6. Remove Sealant Pouch (provided), from protective cover. Grasp both
sides of the sealant pouch and pull until there is no barrier between both
solutions in the pouch.
7. Mix the sealant by alternately squeezing each end of the sealant pouch,
moving the sealant back and forth until the solutions are completely
mixed together.
8. Cut off the corner of the sealant pouch and immediately pour into the
wiring compartment completely covering the conduit entries - DO NOT
FILL PAST LOWER HOUSING BOSS SURFACE (see fig. 3). Allow sealant to
dry for approximately 20 minutes.
9. Coil LED engine to supply conductor wiring and stuff into housing
cavity.
10. Position LED engine onto lower silicone O-ring and align screw holes.
11. Place upper O-ring onto sealing surface of LED engine.
12. Place convex glass lens onto upper O-ring seal.
13. Place fixture cover onto glass lens and align screw holes.
14. Tighten cover screws evenly until there are no gaps between the
fixture housing, LED engine and cover.
15. Supply power to the luminaire and check for proper operation.
NOTE: As a recommended practice for installers of all ingrade luminaries,
Vista strongly recommends replacing the gaskets with new ones each
time the fixture is unsealed for maintenance. Relacement gaskets for
future use are provided for your convenience. Additional gaskets for your
maintenance kit may be purchased through your local Vista Professional
Outdoor Lighting distributor.
Figure 3
Figure 4

This manual suits for next models

2

Other Vista Landscape Lighting manuals

Vista 2205 User manual

Vista

Vista 2205 User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 8202 Series User manual

Vista

Vista 8202 Series User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 4260 Landscape series User manual

Vista

Vista 4260 Landscape series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 8229 User manual

Vista

Vista 8229 User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 2129 User manual

Vista

Vista 2129 User manual

Popular Landscape Lighting manuals by other brands

Luminar Outdoor 93863 Owner's manual & safety instructions

Luminar Outdoor

Luminar Outdoor 93863 Owner's manual & safety instructions

AMP Mini PinnaclePro MR11 Installation & maintenance guide

AMP

AMP Mini PinnaclePro MR11 Installation & maintenance guide

Malibu Boats LZ604B manual

Malibu Boats

Malibu Boats LZ604B manual

Volt Top Dog Scotty Mini Twinnovator Brass installation instructions

Volt

Volt Top Dog Scotty Mini Twinnovator Brass installation instructions

Volt VWL-7125-BBZ installation instructions

Volt

Volt VWL-7125-BBZ installation instructions

Malibu Boats CL905 instructions

Malibu Boats

Malibu Boats CL905 instructions

RAB Lighting FFLED18 installation instructions

RAB Lighting

RAB Lighting FFLED18 installation instructions

SIMES MINIDIAPASON S.4536 quick start guide

SIMES

SIMES MINIDIAPASON S.4536 quick start guide

Kichler Lighting 15384CO instructions

Kichler Lighting

Kichler Lighting 15384CO instructions

enbrighten RGBLL / 72 / 6 / 18 / 2 manual

enbrighten

enbrighten RGBLL / 72 / 6 / 18 / 2 manual

Cooper Lighting Westminster WST50SR2554 Specifications

Cooper Lighting

Cooper Lighting Westminster WST50SR2554 Specifications

LIVARNO LUX Z31096 Assembly, operating and safety instructions

LIVARNO LUX

LIVARNO LUX Z31096 Assembly, operating and safety instructions

superbrightleds PLC-F installation manual

superbrightleds

superbrightleds PLC-F installation manual

LOWE'S MSP002-R0-AA-PK3 manual

LOWE'S

LOWE'S MSP002-R0-AA-PK3 manual

COLORKINETICS Vaya Flood LP G2 installation instructions

COLORKINETICS

COLORKINETICS Vaya Flood LP G2 installation instructions

Inlite FLUX 60 manual

Inlite

Inlite FLUX 60 manual

AMP Lighting PinnaclePro AAL-1016-40-B-BZ Installation & maintenance guide

AMP Lighting

AMP Lighting PinnaclePro AAL-1016-40-B-BZ Installation & maintenance guide

ELAN Lighting ARC33-S-IP user manual

ELAN Lighting

ELAN Lighting ARC33-S-IP user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.