manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vista
  6. •
  7. Landscape Lighting
  8. •
  9. Vista 2129 User manual

Vista 2129 User manual

FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
Shade
Silicone Filled
Safety Connectors
36” Pigtail
Stem
Main Supply Cable
Ground Stake
Turn-to-Lock
Lamp Base
INSTALLATION INSTRUCTIONS - For T3-LED & T3-Halogen
WARNING - TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS:
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamps get hot! Contact only switch/plug when turning on.
3. Do not touch hot lens, guard or enclosure.
4. Keep lamp away from material that may burn.
6. Do not operate luminaire fitting with a missing or damaged cover.
IMPORTANT SAFETY INSTRUCTIONS - THE LIGHTED LAMP IS HOT!
SAVE THESE INSTRUCTIONS (Leave with property owner/manager)
See Reverse for Fixtures with
Integrated LED Module
Brass & Copper
Landscape Series
2129
Path & Spread Lights
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone filled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
LAMP INSTALLATION/REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on luminaire label.
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Loosen lock fastener.
3. Disengage lock.
4. Rotate shade to unlock position.
5. Remove shade and lens to expose lamp.
6. Replace lamp with correct wattage and type marked on fixture label.
NOTE: DO NOT touch lamp with bare hands. Use soft cloth to handle lamp.
7. Re-install shade and lens.
8. Rotate shade & lens to lock position.
9. Engage lock.
10. Tighten lock fastener.
NOTE: Halogen lamps must be protected from moisture and dust at all times.
Always re-install shade and lens when moved.
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
FEMALE CONNECTOR
FROM BASE
MALE CONNECTOR
FROM DRIVER
LOCKING
SET SCREW
LED BASE
SPLICE CONNECTOR
SPT-1 CABLE
VISTA LED DRIVER
The operating voltage range for this LED luminaire is 6 - 15 volt AC. The Vista electronic driver ensures the LED operates at the intended lumen output while
receiving voltage as low as 6 volts, and as high as 15 VAC, resulting in a balanced lumen output from the rst xture to the last. Eliminating the dimness issues
often attributed to voltage drop.
Note: Operating voltage range for LED luminaries will vary depending on model, style and total number of LEDs. To help determine the operating
voltage range for each Vista luminaire, always consult factory’s specification sheet and/or installation instructions before installation.
2129 (08/14)
Shade
Silicone Filled
Safety Connectors
36” Pigtail
Stem
Main Supply Cable
Ground Stake
Turn-to-Lock
Lamp Base
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
See Reverse for Fixtures with
T3-LED or T3-Halogen
INSTALLATION INSTRUCTIONS - For Integrated LED Module
Brass & Copper
Landscape Series
2129
Path & Spread Lights
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone filled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
LED ENGINE INSTALLATION/REPLACEMENT:
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Loosen locking set screw.
3. Rotate Twist-to-Lock shade to unlock position.
4. Remove shade and lens assembly to expose LED Engine.
5. Unscrew brass base from stem.
6. Pull up LED base assembly out of stem.
7. Disconnect connector assembly.
8. Connect new eld replaceable LED engine to connector assembly.
9. Reinstall LED base assembly onto stem.
10. Reinstall Twist-to-Lock shade and secure with locking set screw.

Other Vista Landscape Lighting manuals

Vista 8229 User manual

Vista

Vista 8229 User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 4260 Landscape series User manual

Vista

Vista 4260 Landscape series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 2205 User manual

Vista

Vista 2205 User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 1162 Architectural Series User manual

Vista

Vista 1162 Architectural Series User manual

Vista 8202 Series User manual

Vista

Vista 8202 Series User manual

Popular Landscape Lighting manuals by other brands

Portfolio 19548-000 manual

Portfolio

Portfolio 19548-000 manual

Sunforce SOLAR INDUSTRIAL GARAGE LIGHT user manual

Sunforce

Sunforce SOLAR INDUSTRIAL GARAGE LIGHT user manual

IP44.de in S Instructions for use

IP44.de

IP44.de in S Instructions for use

Beckett Accent Lighting LT20 Specifications

Beckett

Beckett Accent Lighting LT20 Specifications

Malibu Boats LD622 Assembling & installation instructions

Malibu Boats

Malibu Boats LD622 Assembling & installation instructions

Beachside Lighting MB4 12V instructions

Beachside Lighting

Beachside Lighting MB4 12V instructions

EasyPro RGB9PL Instructions for operation

EasyPro

EasyPro RGB9PL Instructions for operation

Ares 53012 Operation manual

Ares

Ares 53012 Operation manual

AMP Lighting AFL-4012-4-B-BZ Installation & maintenance guide

AMP Lighting

AMP Lighting AFL-4012-4-B-BZ Installation & maintenance guide

Malibu Boats LZ508 instructions

Malibu Boats

Malibu Boats LZ508 instructions

Paradise Datacom M52731 instructions

Paradise Datacom

Paradise Datacom M52731 instructions

Solar Technology International Venetian SM41303 instructions

Solar Technology International

Solar Technology International Venetian SM41303 instructions

Malibu Boats LT8 instructions

Malibu Boats

Malibu Boats LT8 instructions

Volt 3602 Series installation instructions

Volt

Volt 3602 Series installation instructions

LIGMAN VANCOUVER 30 installation manual

LIGMAN

LIGMAN VANCOUVER 30 installation manual

Malibu Boats LZ10131 instructions

Malibu Boats

Malibu Boats LZ10131 instructions

Sulion YUKA manual

Sulion

Sulion YUKA manual

Global Light & Power LCC WW440210 Installation instruction

Global Light & Power LCC

Global Light & Power LCC WW440210 Installation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.