VOCA TC-X User manual

Tankless, instant hot and ltered water tap
Instrucon Manual
fresh
28

01
IMPORTANT!
This appliance is not intended for people with physical, sensory or metal
disabilies. Children or people with special needs should be supervised at
all mes while operang it, to ensure their own safety and avoid injuries.
The appliance is intended for households and similar applicaons (e.g. staff
kitchen areas in shops/offices/etc, rural properes, for clients in
hotels/motels/etc, bed and breakfast).
Please pay parcular aenon immediately aer using the appliance/water
tap (especially with higher temperatures sengs) as residual heat may be
present for some me aer use.
To ensure its funconality and safety, please do not alter the product in any
way and only use it for its intended purposes.
To ensure the correct funoning and longevity of the appliance, please
clean it regularly. Do not use any abrasive materials and only use substances
fit for human consumpon.
If the power cord is damaged, please seek qualified professional help to
fix/replace it to avoid any danger.
Please ensure to remove the power supply before proceeding with any sort
of maintenance.
Please make sure to install the appliance vercally as instructed and in a
safe place, away from water or rain. Excessive humidity or direct sunlight
may affect the normal operaon and longevity of the appliance.
In order to ensure maximum efficiency, it may take up to 3-5 seconds before
a temperature above 80° can be reached.
If the water temperature is set more than 3° below the Original Water
temperature, no water will be released.
The warning codes described under secon 19 of this manual only describe
an operaonal issue, not the Main Unit’s failure. Unless the issue is
constantly persistent, it should not constute a wider concern.
For up-to-date informaon and addional ps on how to properly use and
maintain the appliance, please visit our website and social media pages.
Please read the filter’s literature carefully to ensure appropriate use and
installaon of the product.
fresh
Please read all instrucons carefully
before using the appliance!
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.

02
Please fully charge the device prior first use (unl the icon disappears)
Important!
Wireless charging area Wireless charging icon
To charge wirelessly, please center the icon on the charging pad (not supplied).
The device cannot be charged wirelessly and through the USB port at the same me!
Important!
As wireless charging can cause the device to heat up considerably, we
recommend to only use it as an emergency/backup opon.

03
fresh
What’s Included
Low Baery Indicator
Charging The Device
Sleep/Wake-up
Wireless Touch Controller Appearance
Touch Display Overview
Touch Faucet - Touch Controls Instrucons
Touch Faucet - Auto-stop Funcon
Main Unit Display
Installaon And Calibraon Process
Selecng The Right Faucet
Pairing The R2 Wireless Touch Controller
Seng Up Filter Monitoring
Cancelling Filter Monitoring
Filter Element Monitoring Icon
Checking The Status Of The Filter Element
Replacing The Filter Element
Quick Memory Programme Seng
Pre-programmed Shortcut Keys
Seng The Desired cc Quanty
Operang With No Set cc Quanty
UV Element (oponal)
Wireless Recepon Icon
Checking The Water Pressure
Changing The Keys Sound
Warning Codes (R2 Wireless Touch Controller)
Table of contents
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
01
02
02-1
02-2
03
04
05
05-1
06
07
08
08-1
09
09-1
09-2
10
11
12
13
14
14-1
15
16
17
18
19

04
01 What’s included
Stainless Steel Touch Controlled Faucet
R2 Wireless Touch Controller
Main Unit
USB Charging Cable
Alcohol Sanising Wipe
R2 Wall Mount, R2 Stand
02 Low Baery Indicator
When the baery is low, the icon will appear on the screen.
02-1 Charging The Device
Plug the USB cable and connect the R2 Wireless Touch Controller
to a USB charger or place the device on a compable wireless
charging pad. The icon will start flashing. Once fully charged,
the icon will disappear.
02-2 Sleep/Wake-up
The device will automacally go into sleep mode aer an inacvity
of 10 seconds. To wake it up again, simply tap the display.
Note: the device may wake up in the event of surrounding noise or vibraons.
1x
1x
1x
1x
1x
2x
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________

05
fresh
UV
03 Wireless Touch Controller Appearance
Wireless Touch Panel
Stand or wall mount holes / Wireless
charging area
USB charging port
Front
View
Rear
View
Boom
View

06
UV
04 Touch Display Overview
Temperature °C
Quanty
Filter Usage
Error Warning
Wireless recepon
Shortcuts
Quanty Seng
Input Number Keys
Start/Stop Keys
Baery/Charging
UV indicator
Note: when in standby, the given °C shows the original water temperature.

07
fresh
05 Touch Faucet - Controls Instrucons
The touch-enabled faucet is equipped with 3 illuminated pre-set
touch buons. The built-in LED light ensures visibility over the
water level in low-light environment.
To operate it: press a buon once to start the water flow and
press it again to stop. The Hot Water buon has an added
safety feature: press it once (the icon will start to flash), then
press it again to start the water flow. While flashing, the
auto-safety mode will reset itself aer 5 seconds.
Hot Water
between 90-95°C
Warm Water
between 55-60°C
Original Water
05-1 Touch Faucet - Auto-stop Funcon
Touch and hold any buon for 2 seconds: the icon will flash and
the flow will stop automacally aer 200cc.
Touch once (less than 2 seconds): the icon remains on and the
flow will stop automacally aer 2000cc (safety feature).
Note: 1cc = 1ml | 100cc = 10cl | 1000cc = 1lt

08
06 Main Unit Display
Voltage
Current
Temperature
This product heats and supplies filtered water. It does not have a boiling funcon and the
incoming filtered water should meet the drinking water quality standards set by the local
environmental protecon department.
07 Installaon And Calibraon Process
Note: water will be released during the calibraon process.
Aer plugging in the power supply for the first me, you can
choose between two opons to calibrate the Main Unit:
Touch Faucet - Touch all three buons at the same
me for 2 seconds. Aer the long beep, press the Warm Water
buon to start the calibraon process.
R2 Wireless Touch Controller - Press the key eight mes to
start the calibraon process.
A long fading beep idicates that the calibraon was successful!
If you hear 3 short beeps the calibraon has failed. Please follow the
troubleshoong guide or contact your supplier.
Note:

09
fresh
08 Selecng The Right Faucet
The system rocognises different kind of faucets. The R2 Wireless
Touch Controller needs to be linked with the correct faucet.
Please follow the instrucon below to select the right one.
On the R2 Wireless Touch
Controller press for four
mes, then select your faucet:
Standard Faucet
Touch Faucet
08-1 Pairing The R2 Wireless Touch Controller
If the R2 Wireless Touch Controller cannot be operated, please
follow the instrucons below to pair it with the Main Unit.
(Acvate the pairing mode)
With the Touch Faucet:
Touch all 3 buon
unl you hear the long beep.
Touch the Original Water
buon once, then the
Warm Water buon once.
Go to STEP2.
With the Standard
Faucet: Unplug the
Main Unit for at least 10
seconds, then plug it back
in. You’ll hear a long beep.
On the R2 Wireless Touch
Controller, press for four
mes, then press any number
between .
Press to confirm.
Note: STEP1-2 need to be completed within 10 seconds!

10
You can now set the signal
booster funcon. On the R2
Wireless Touch Controller
press for eight mes. Then
select and press unl you
hear the long beep to confirm.
09 Seng Up Filter Monitoring
(1) Using the Touch Faucet
Once the filter element has been used for 2 years or it reached
80% of the set gallons, the icon on the Touch Faucet will light
up as a reminder that the filter needs to be replaced soon. Aer
installing a new filter, press all three buons for 2
seconds unl you hear a long beep. Press the Original Water
buon twice, then the Warm Water buon once. The
filter indicator will disappear, confirming that the seng is
complete.
(2) Using the R2 Wireless Touch Controller
While on standby, press the key
eight mes.
Enter the life expectancy in gallons (eg
1500), then press the key.

11
fresh
Aer a long beep, the main screen will
appear. Seng is complete.
When the water consumpon reaches the set amount or aer the
2-year service has passed, the R2 Wireless Touch Controller will
display the icon as a reminder that the filter needs to be
replaced. Please follow the instrucons STEP1-STEP3 to reset the
filter monitoring.
Note:
09-1 Cancelling Filter Monitoring
By following the above STEP1-STEP3, enter the filter’s life
expectancy as 0.
Note: the system uses gallons to measure the filter longevity.
1 gallon = 3.7854 litres. Please check the filter’s
specificaons to ensure you set the correct filter life
expectancy.
where available, the Touch Faucet red filter indicator will
also appear when required.

12
09-2 Filter Element Monitoring Icon
If the Filter Monitoring has not been set or the value was set as 0, the below
icon will not be shown. The filter element’s minimum seng is 100 gallons.
Filter Element
Icon
The filter element has full capacity 100%.
Capacity is 75%, already consumed 25%.
Capacity is 50%, already consumed 50%.
Capacity is 25%, already consumed 75%.
The filter has been fully consumed or a period
of 2 years has been reached.

13
fresh
11 Replacing The Filter Element
Aer a new filter element is installed, we recommend to run original
temperature water for about 3-5 minutes to rinse the filter. You can use the
safety discharge valve (if installed) or set up a 9999cc quanty through the
R2 Wireless Touch Controller.
Rotate
clockwise
to unlock
Pull down
to remove
Push up
to replace
Rotate
an-clockwise
to lock
10 Checking The Status Of The Filter Element
While not operang, touch all three buons on the
Touch Faucet for 2 seconds unl you hear a long beep. Press the
Original Water buon three mes, then the Warm Water
buon once. Water will be released while the Main Unit’s
display will show the following data in sequence:
Used gallons (eg 170) Tot set gallons (eg 800) Used me (eg 18 months)
Note: This funcon can only be started while on standby.

14
12 Quick Memory Programme Seng
The system offers 10 programmable sengs for convenience.
Press and hold any number
between unl you
hear a long beep.
Set the temerature (eg 60°):
press and to confirm.
Set the quanty (eg 250cc):
press and to confirm.
Aer a long beep, the main
screen will appear. The
seng is complete.
To use a saved quick programme, select the number you
chose between then press . Finally press to
start the water release.
If no quanty is set, as a safety measure it will
automacally stop once it reaches 2000cc.
Note 1 :
Note 2 :

15
fresh
13 Pre-programmed Shortcut Keys
The system has four build-in shortkut keys. To use one of them,
simply press one of the icons, then press and finally to
start the water release.
Original
Water
Milk
(60°)
Hot Drink
(85°)
Cooking
(95°)
You can adjust the Milk seng according to your needs:
Press and hold the Shortcut
unl you hear the beep.
You’ll enter the set up screen.
Set the new temp. (eg 65°):
press and to confirm.
Aer a long beep, the main
screen will appear. The seng is
complete.

16
14 Seng The Desired cc Quanty
If no quanty is set, as a safety measure the water release will
automacally stop once it reaches 2000cc.
Press a shortcut key or enter the
desired temperature.
Press the icon.
Enter the cc quanty (eg 250cc):
press and to confirm.
Press to start the water release.
The display will start a
countdown unl finished.

17
fresh
14-1 Operang With No Set cc Quanty
When the quanty is set to 0000cc:
If no quanty is set, press directly. Press to start the water release.
The display will count the cc
unl it is stopped with or when it
reaches 2000cc.

18
15 UV Element (Oponal)
When the oponal UV Element is installed and the icon appears
on the R2 Wireless Touch Controller, the UV Element is not
working properly. Please seek assistance.
In combinaon with the Touch Faucet, in the above event a blue
light will signal the abnormality.
UV Icon

19
fresh
16 Wireless Recepon Icon
When the water is flowing, the wireless antenna icon will
appear. If the recepon is good, a full three line icon will
appear. The lines will decrease depending on signal intensity.
Antenna
Icon
17 Checking The Water Pressure
Press for four mes.
Note: the faucet will release water during this process.
The bigger number shows the
pressure PSI while on standby. The
smaller number shows the
pressure PSI while water is being
released.
Other manuals for TC-X
1
Table of contents
Popular Controllers manuals by other brands

Honeywell
Honeywell Stryker VAV operating guide

KMC Controls
KMC Controls CSC-3501 installation guide

VADDIO
VADDIO HOT-SHOT Installation and user guide

Monacor
Monacor img Stage Line CU-3LED manual

KMC Controls
KMC Controls KMD-5210 Installation and operation guide

Meridian
Meridian Analogue Controller 502 user guide