Vogel FALKE User manual

User manual for the FALKE device
from VOGEL, the latest device for
detecting and distinguishing
between different metals.
FALKE
www.vogeldetectors.com
User Manual
Metal and Water Finder

ماﺪﺨﺘﺳﻻا ﻞﻴﻟد ةءاﺮﻗ
. ﺚﺤﺒﻟا أﺪﺑ ﻞﺒﻗ ﺪﻴﺟ
Page 1
Index
Technical Specications
Important Notes
Assembly
Getting Started
Main Unit Setup and Start Working
Calibration/Automatic Calibration
Page 1
Page 2
Page 3
Page 8
Page 10
Page 11
Page 16
Searching setup
Page 15
Searching Modes
Page 18
Manual Calibration
Page 17
Accurate identication
Page 23
Notes
Page 29
Main Unit
Page 9
Introduction
Page 5
Why Falke
Page 6
Contents
Page 7
Treasure Mode
Page 20
Graph Mode
Page 19
Coins Mode
Page 22
Depth Mode
Page 27

The user strips himself of metal, such as rings watch, or a metal belt
Do not store the device in a place with high temperatures and
humidity.
Page 2
The user should practice on how to use the device before setting off
for detection and search operations.
The user should practice how to use the device before setting off for
detection and search operations.
The device must be connected to the searching coil during
operation
In the case of tampering with the device, the device will lose its
security.
IMPORTANT NOTES

Page 3
search for:
Searching for metals, gold and blanks.
searching system:
Very low frequency VLF system
Operator
mikrocontroller
Operating system
A system for measuring and processing levels of the electromagnetic eld
formed around the target and the receiver through the reception coil in the
search coil, analyzing these results and showing them through sound alerts
and color graphic indicators on the screen.
Sound alert YES
Three cells Li-ion 3.7 V, 3000 mA Power output 8.4 V
working hours 10 hours
Power
Charger 12 volts 2 amps / charging time 2 hours
Display 5 inch color TFT screen.
TECHNICAL SPECIFICATIONS

Page 4
Operating temperature:
From -15 °C to 60 °C
storage temperature:
From -15 °C to 40 °C
Humidity :
Bag dimensions:
It can be stored and operated at an average air humidity of
5% to 75%.
weight:
Dimensions:
17 x 21 x 5 cm
66x51x26 cm
8 Kg

Page 5
: ﺔﺑﻮﻃﺮﻟا
ًُ
FALKE is the best device of what was produced by the German company VÖGEL and the
latest in metal detector technology. This device is characterized by dierent systems and
multiple search options in order to reach the most accurate results in the search for targets.
FALKE device through its unique search systems and various analysis algorithms saves the
work of the prospectors and shortens the eort and time spent during dicult excavations.
It is also characterized by advanced search settings that allow ignoring unwanted targets
during the search, which facilitates the work of prospectors
FALKE device is equipped with four dierent search modes. Each system has its own unique
features to show search results on screen through interactive graphical interfaces and alerts
- Graph Mode
- Treasures Mode
- Coins Mode
- Depth mode
The device allows the user to adjust the search settings to suit the search requirements
Desensitization to iron
Increase or decrease the sensitivity in proportion to the electromagnetic nature of the soil
Manual and automatic calibration
INTRODUCTION

Dear customer, we appreciate your trust in us and your acceptance of a new and unique
experience in the world of metal detectors by owning one of our products.
The Falke device has a number of features and characteristics, including:
- The special design of the (DoubleD) search coil to avoid magnetic anomalies caused by
metallic minerals.
- The ability to isolate mineral and rocky soils, ie canceling magnetic noise without aecting
sensitivity, thus giving greater eectiveness and a more accurate allergic eld during the
research.
- Complete the search task without interruption due to the unique advantage in the
number of continuous working hours, which
Up to ten hours straight.
Fast Charging: The Falke takes only 2 hours to fully charge.
- High-resolution color interactive interfaces to give the search process a lively character.
Page 6
WHY FALKE...?
16 |

Page 7
CONTENTS
warranty card
Main Unit
Device Bag
Handel
User Manual Charger Hedphone
search coil 33 cm
search coil 45 cm
Designed according to standard
parameters to give a wide
sensitivity range
Designed according to standard
standards to sense pieces of small
sizes

6
ASSEMBLY
12
3
1- We open the handle locks to
calibrate the length of the
handle.
2- Lengthening or shortening
both arms of the carrying
handle in proportion to the
user.
3- When determining the
appropriate length for each of
the forearms, we close the
locks to give them movement.
4- Putting rubber protection to
prevent friction between the
handle and the search disk.
5- Place the contact head of the
handle in the place designated for
it in the search coil.
6- Inserting the fixing shaft into
the channel designated for fixing
the handle to the search coil.
7- Turn the locking nut clockwise.
8- Align the coil plug and insert it
into the socket on the side of the
main unit.
9- Slightly tighten the retaining
ring clockwise to secure the cable.
4
98
57
6
Page 8
HANDEL SETUP
CONNECT THE HANDEL WITH SEARCHING COIL
CONNECT THE JACK WITH THE DEVICE

Page 9
4
39
25
8
7
MAIN UNIT
10 12
1
611
ًا
ً
1
ًً
2
ً
1 25 ً
3
ضر EQUINOX Series
Power button ON/OFF
1
2
3
Move buttons
7
OK button
5
9
TFT display
Hold button
Back button
Charger socket
4
Calibration button
8
Pinpoint button
5
6
searching coil socket
10
Hedphone socket
11
speaker
12

Wiping should be done by keeping the search coil parallel to the soil surface while avoiding
excessive rubbing of the coil on the floor as shown in the figure.
In order for the search to be complete and without leaving unchecked areas, it is not possible to move
and move randomly, but by moving it from side to side, moving forward slowly at the end of each
scanning movement. Overlap a little with the previous sweep to make sure the floor is completely
covered. So that the average speed of a single scan movement is 2to 3seconds from right to left to right.
When moving the search coil during the search, the search coil must be kept perpendicular to the
surface of the soil, as this will increase the depth of detection and improve the detector's response to
small objects.
Page 10
GETTING STARTED
Page 5
CO RRECT U S E
CO RRE CT WAY OF SWEEPING
Shaft height is wrong Shaft height is correct
5cm (~2'') above the ground.
accurate results.
Wrong search coil angle Wrong search coil angle Correct search coil angle
Incorrect way of sweeping Correct way of sweeping
Page 5
CO RRE CT U S E
CO RRE CT WAY OF SWEEPING
Shaft height is wrong Shaft height is correct
5cm (~2'') above the ground.
accurate results.
Wrong search coil angle Wrong search coil angle Correct search coil angle
Incorrect way of sweeping Correct way of sweeping
3 2
•
•
•
•

© MWF DETECTORS TECHNOLOGY . ALL RIGHTS RESERVED.
By VÖGEL Metalldetektor with MWF Detector association
Page 11
MAIN UNIT SETUP AND START WORKING
Turn on the device by pressing the Power Button
The boot screen will appear and then the interface of the connection mode with the search coil

MAIN MENU
SETTING SEARCH
Page 12
MAIN MENU
SETTING SEARCH
This status appears if the search coil is connected This condition appears if the search coil is not connected
The main interface contains two icons. Search to enter the search and settings menu to adjust the
device settings and an indicator of the battery charge level is present in all interfaces. Moving
between icons is done by pressing the Move buttons. To confirm one of the two options, press the
OK button
When selecting the Setting icon
When selecting the search icon

Page 13
SETTING
SETTING
When choosing the settings icon and pressing the enter button, we will see asettings interface
that enables us to reset the device. It contains options for adjusting the brightness, sound, and
.language of the device, in addition to the possibility of restoring the device to factory settings
volume setting: when selecting the volume icon, the volume is changed by pressing the
Enter button. To change the volume according to eight levels, we press the increase and
decrease buttons
brightness setting: When selecting the brightness icon, the screen brightness value is changed
by pressing the OK button. The brightness value changes according to eight brightness levels
from
10%
to
100%
.
We press the increase and decrease buttons

Page 14
Factory
Reset
SETTING
Español
Deutsch
Pусский
SETTING
Language setting: When selecting the language icon to change the language, we press the
enter button to go to the languages interface. The device has six languages: English, German,
French, Arabic, Spanish and Russian. The transition between these languages is done through
the navigation buttons, and to confirm one of the languages, we press the OK button
To return to the settings interface, press the Back button
Factory reset: When selecting the factory reset icon, factory settings can be restored by
pressing the OK button

Page 15
SEARCHING SETUP
SEARCH MENU
SEARCH MODESEARCH SETTING
SEARCH SETTING
ON OFF
MANUAL
AUTOMATIC
Iron sensing or desinsing
sensitivity adjesting
calibration modes
Search settings: To adjust the search settings, there are three options
-The option to cancel or activate the sensitivity to iron
- The option to decrease or increase the sensitivity level within ten levels of sensitivity
- Manual or automatic calibration option
The transition between these options is done by pressing the scroll buttons, and to confirm one
of the options, we press the confirmation button
When selecting the search icon and pressing the OK button, the search menu appears, which
contains the search Mode and search settings
To return to the search menu, press the Back button.

Page 16
When you press the automatic calibration
option, the user will see an instruction
interface asking him to raise the dial a distance
of 35 cm from the surface of the earth and
then press the OK button to ask him to lower
the search coil to a height of 10 cm. We notice
an increase in the percentage of the indicator
with a beep at this height.
We press the OK button and the value will be
zeroed and the beep disappears to ask the user
to raise the disc to a height of 35 cm and press
the enter button and decrease the disc to 10
cm we notice the alarm ring and the indicator
value is repeated. The process of raising and
lowering the disc is repeated with pressing the
enter button each time until The indicator
value at a height of 10 cm becomes zero and
the alarm disappears.
CALIBRATION
AUTOMATIC CALIBRATION
85%
35 cm
CALIBRATION SETTING
LIFT THE COIL 35 CM OFF THE
GROUND AND PRESS ENTER
10 cm
0%
CALIBRATION SETTING
LIFT THE COIL 10 CM OFF THE
GROUND AND PRESS ENTER
Note: When operating the device, a soil calibration must be performed before starting work
by pressing the Calibration button and following the instructions mentioned about
calibration on page 16.

Page 17
Non zero magnetic harmonic
Zero magnetic harmonic
10 cm
60%
CALIBRATION SETTING
10 cm
0%
CALIBRATION SETTING
CALIBRATION SETTING
VALUE : 250
VALUE : 255
VALUE : 270
GROUND CALIBRATION IS DONE
PRESS ENTER
Then we press the Enter button to complete the calibration process, and the user is shown a
message of completion of the calibration, in which the average calibration value appears,
and the user is asked to press the OK button to start the search process.
Note: If the calibration is not achieved, the user must repeat the previous steps.
When pressing the manual calibration option by pressing the move button and then
conrming through the enter button, the manual calibration interface appears asking the
user to raise the search coil from the ground surface by 10 cm and move it up and then
return to a height of 10 cm with manually changing the calibration value by pressing the
transition buttons, until the percentage becomes zero with repeated lifting from the
ground and returning it to a height of 10 cm from the ground more than once, in order to
obtain the magnetic harmonic of the soil surface, when we obtain the zero magnetic
harmonic of the soil, we press the enter button to nish the calibration process And go to
the search interface.
MANUAL CALIBRATION

Page 18
If there is metal
SEARCHING MODE
Graph Treasures Coins Depth
SEARCH MODE
When entering the search interface, we press the move button (move) to detect the search
mode icon then press the OK button to enter the search mode interface, which contains
four dierent search modes.
Note: The calibration process must be performed before starting the research process,by
pressing Calibratition button.

If there is metal
If there are caves and voids
Page 19
GRAPH MODE
Depth
SEARCH MODE
Metals
Depth
SEARCH MODE
Metals
Caves
&
Mineral
Caves
&
Mineral
Entering the Chart Pattern is done by pressing the OK button to show the Graph mode
interface.
The interface of the graph mode contains two graphs, the rst showing the results of the
showing of minerals in the search area, and the second showing the results of Minerals
and caves.
Note: You can pause and restart the search process by pressing the Hold button.
Note: Calibration can be performed by pressing the Calibration button to go to the search
settings interface, allowing the user to choose the expression pattern (manual - automatic)
by pressing the navigation buttons and the OK button to choose one of the two patterns
and follow the instructions on the screen.
Note: The user has to press the enter button periodically to re-initialize the signal during the
search to cancel the eect of transient signals.
Table of contents
Other Vogel Media Converter manuals
Popular Media Converter manuals by other brands

Delta Electronics
Delta Electronics Delphi S24SA datasheet

Advantech
Advantech B+B SmartWorx 422CFCR quick start guide

Archive
Archive UDA-501 user manual

True blue power
True blue power TC120 Installation manual and operating instructions

ICP DAS USA
ICP DAS USA TM-7561 user manual

Mastervolt
Mastervolt Sine 24/250 user manual

Vertiv
Vertiv Netsure user manual

Sony
Sony XDBK-103 operating instructions

Sony
Sony XV-T33 - Video Sketch Titler operating instructions

RLH Industries
RLH Industries 2 Channel 4 Wire Datawith E&M and I/O user guide

CARLO GAVAZZI
CARLO GAVAZZI UCC user manual

Allen-Bradley
Allen-Bradley 931S-F1C2D-DC installation instructions