Void Bias Q3 User manual

voidacoustics.com
Bias Q3
USER GUIDE V1.0

Page 2 UG10553-1.0 - Bias Q3 User Guide V1.0
Safety Warnings
+50 C
0 °C
OPERATING TEMPERATURE RANGE: 0°C TO +50°C - DERATING ABOVE 35°C.
10%
90%
%STORAGE RELATIVE HUMIDITY RANGE: 10% TO 90% HUMIDITY (NON CONDENSING).
DO NOT USE THE UNIT AT ALTITUDES ABOVE 2000 M.
DO NOT USE THE UNIT IN TROPICAL ENVIRONMENT.
CLASS3
WIRING
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT. NO
USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CLASS3
WIRING
CONNECTION TO THE MAINS SHALL BE DONE ONLY BY A ELECTROTECHNICAL SKILLED PERSON
ACCORDING THE NATIONAL REQUIREMENTS OF THE COUNTRIES WHERE THE UNIT IS SOLD.
CLASS3
WIRING
DO NOT USE THIS AMPLIFIER IF THE ELECTRICAL POWER CORD IS FRAYED OR BROKEN.
CLASS3
WIRING
TO AVOID ELECTRICAL SHOCK, DO NOT TOUCH ANY EXPOSED SPEAKER WIRING WHILE THE
AMPLIFIER IS OPERATING.
CLASS3
WIRING
DO NOT SPILL WATER OR OTHER LIQUIDS INTO OR ON THE AMPLIFIER.
CLASS3
WIRING
THIS DEVICE MUST BE POWERED EXCLUSIVELY BY EARTH CONNECTED MAINS SOCKETS IN
ELECTRICAL NETWORKS COMPLIANT TO THE IEC 364 OR SIMILAR RULES
CLASS3
WIRING
DISCONNECT THE AC MAINS SOURCE BEFORE ATTEMPTING TO CLEAN ANY PART OF THE AMPLIFIER
CLASS3
WIRING
POWERSOFT SUGGESTS TO PLUG THE TTM SERIES TO A 16 A RATING, C OR D CURVE, 10 kA
SECTIONING BREAKER.
CLASS3
WIRING
OUTPUT TERMINALS ARE HAZARDOUS: WIRING CONNECTION TO THESE TERMINALS REQUIRES
INSTALLATION BY AN INSTRUCTED PERSON AND THE USE OF READY MADE LEADS.
CLASS3
WIRING
PROPERLY FIT THE AC MAINS PLUG TO THE AMPLIFIER INLET.
BEFORE POWERING THIS AMPLIFIER, VERIFY THAT THE CORRECT VOLTAGE RATING IS BEING USED.
CLASS3
WIRING
TAKE CARE TO LOCK THE OUTPUT TERMINAL BEFORE SWITCHING THE DEVICE ON.
CLASS3
WIRING
VERIFY THAT YOUR MAINS CONNECTION IS CAPABLE OF SATISFYING THE POWER RATINGS OF THE
DEVICE.
CLASS3
WIRING
NO NAKED FLAME SOURCES SUCH AS LIGHTED CANDLES SHOULD BE PLACED ON THE AMPLIFIER.
CLASS3
WIRING
TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY RACK MOUNTED IN ACCORDANCE WITH
THE INSTALLATION INSTRUCTIONS.
CLASS3
WIRING
THIS EQUIPMENT SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 2 M
CLASS3
WIRING
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED TO PERSONS,
THINGS OR DATA DUE TO AN IMPROPER OR MISSING GROUND CONNECTION.
CLASS3
WIRING
IT IS ABSOLUTELY NECESSARY TO VERIFY THESE FUNDAMENTAL REQUIREMENTS OF SAFETY AND, IN
CASE OF DOUBT, REQUIRE AN ACCURATE CHECK BY QUALIFIED PERSONNEL.
Common symbols and meanings
CLASS3
WIRING
THE TRIANGLE WITH THE LIGHTNING BOLT IS USED TO ALERT THE USER TO THE RISK OF ELECTRIC
SHOCK.
CLASS3
WIRING
THE TRIANGLE WITH THE EXCLAMATION POINT IS USED TO ALERT THE USER TO IMPORTANT
OPERATING OR MAINTENANCE INSTRUCTIONS.
THE CE-MARK INDICATES THE COMPLIANCE OF THE PRODUCT TO ALL THE APPLICABLE EUROPEAN
DIRECTIVES
SYMBOL FOR EARTH/GROUND CONNECTION.
SYMBOL INDICATING THAT THE EQUIPMENT IS FOR INDOOR USE ONLY.
SYMBOL FOR CONFORMITY WITH DIRECTIVE 2012/19/EC OF THE EUROPEAN PARLIAMENT ON WASTE
ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE).
CAUTION
RISK OF ELECTRIC
SHOCK DO NOT OPEN
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Important Safety Instructions

Page 3
UG10553-1.0 - Bias Q3 User Guide V1.0
Europe
USA
FCC Supplier’s Declaraon of Conformity
50018 Scandicci (FI) – Italy
FCC Compliance Statement
•
•
•
•
Canada
Canadian Cauon
ICES-003 Class A Noce - Avis NMB-003, Classe A
Radiaon Exposure Statement
Énoncé d’Exposion à la Radiaon Ic
Regulatory Compliance Statements

Page 4 UG10553-1.0 - Bias Q3 User Guide V1.0
•
•
•
•
•
•
•
AC Mains Supply

Page 5
UG10553-1.0 - Bias Q3 User Guide V1.0
.
Speaker Preset
► , in
HOME
BACK
Bias Q3
1 >60 dB
2 >60 dB
3- Stasys Xair >60 dB
4- Stasys Xair >60 dB
1 2 3 4
5
✓

Page 6 UG10553-1.0 - Bias Q3 User Guide V1.0
3
1
3
1
1 RU
1 RU
1 RU
1 1
4
2
4
2
2 2
5 5
3
5
3
5
6 6
4
6
4
6
7
FW Update
It is recommended to always turn on the DHCP server before
connecng the ampliers.

Page 7
UG10553-1.0 - Bias Q3 User Guide V1.0
12345678
Color code (TIA/EIA-568-B) Pin
ORANGE / WHITE 1
ORANGE 2
GREEN / WHITE 3
BLUE 4
BLUE / WHITE 5
GREEN 6
BROWN / WHITE 7
BROWN 8
12
3
GND
HOT
COLD
GND
HOT
COLD
21
3
Pin#
1
2
3
speakON
connector
output
stage A
output
stage B
CHA +
A
CHB +
B
Bridge-tied load
Two single-ended loads
CHB –
CHA –
A
B
speakON
connector
output
stage A
output
stage B
CHA +
CHB +
CHB –
CHA –
A
B
1+
2+
1–
2–
1+
2+
1–
2–
1+
2+
1–
2–
1+
2+
1–
2–
1+
1-
2+
2-
Pin#
1
2
3
speakON
connector
output
stage A
output
stage B
CHA +
A
CHB +
B
Bridge-tied load
Two single-ended loads
CHB –
CHA –
A
B
speakON
connector
output
stage A
output
stage B
CHA +
CHB +
CHB –
CHA –
A
B
1+
2+
1–
2–
1+
2+
1–
2–
1+
2+
1–
2–
1+
2+
1–
2–
1+
2-
1+
2+
1–
2–
1+
1-
2+
2-

Page 8 UG10553-1.0 - Bias Q3 User Guide V1.0
Rear Panel
7CH1 (1+/-) | CH2 (2+/-)
8CH2 (1+/-) | N.C. (2+/-)
9CH3 (1+/-) | CH4 (2+/-)
10 CH4 (1+/-) | N.C. (2+/-)
15 Input 1 (XLR-F)
16 Input 2 (XLR-F)
17 Input 3 (XLR-F)
18 Input 4 (XLR-F)
19 Link Out 1 (XLR-M)
20 Link Out 2 (XLR-M)
21 Link Out 3 (XLR-M)
22 Link Out 4 (XLR-M)
AES3
11 AES3 In 1-2 (1GND/2+/3-)
12 AES3 In 3-4 (1GND/2+/3-)
13 AES3 Link Out 1-2 (1GND/2+/3-)
14 AES3 Link Out 3-4 (1GND/2+/3-)
23 ETH 1 (RJ45)
24 ETH 2 (RJ45)
1Main Menu
2
3
4
IEC C19
12
14
18
22
2416
20
11
13
17
21
2315
19
10
8
9
7
1
2
3
4

Page intentionally left blank

Page intentionally left blank

Page intentionally left blank

voidacoustics.com
NORTH AMERICA
Void Acoustics North America
Call: +1 503 854 7134
Email: [email protected]
HEAD OFFICE
Void Acoustics Research Ltd,
Unit 15, Dawkins Road Industrial Estate,
Poole, Dorset,
BH15 4JY
United Kingdom
Call: +44(0) 1202 666006
Email: [email protected]
Table of contents
Other Void Amplifier manuals