Votronic Solar Controller SR 150 Duo Digital User manual

Installation and Operating Manual
Solar Controller SR 150 Duo Digital
12 V / 9.5 A (150 Wp)
No. 1611
Solar Controller SR 230 Duo Digital
12 V / 14.5 A (230 Wp)
No. 1616
Solar Controller SR 350 Duo Digital
12 V / 22.0 A (350 Wp)
No. 1621
Solar Controller SR 550 Duo Digital
12 V / 35.0 A (550 Wp)
No. 1626
Please read this assembly and operating instructions completely, in particular, page 2
"Safety Regulations and Appropriate Application", before you begin the connection and start-up.
For campers and caravans.
The solar controller is a special development for use in campers and caravans, and it is suitable for all types and makes of
lead batteries (also for acid, GEL/dryfit, AGM/fleece batteries). Optimum charging is ensured by an intelligent
microprocessor control with characteristic lines IU1oU2.
Working fully automatically and maintenance-free, the solar controller offers the following functions:
Battery Ports and Charging Programs:
Charging port leisure battery, depending on the type of battery, 3 charging programs selectable (see table 1):
Lead Battery:
a) "Liquid Acid/AGM1":
Closed and open acid/lead-acid batteries, as well as AGM with indication 14.4 V
b) "AGM2":
Closed, gas-tight AGM/fleece batteries (absorbed glass Mat, lead-fleece technology) with
the indication 14.7 V.
c) "Gel":
Closed, gas-tight Gel/dryfit batteries (determined electrolyte)
Charging Port Starter Battery:
Separate auxiliary charging port with reduced charging current (12 V (0.8 A or 1.5 A) for support charging and trickle
charging of the vehicle’s starter battery with overcharge protection in case of extended stop periods.
Further Characteristics of the Unit:
•
The charging voltage being free from peaks is controlled in such a way, that any overcharging of the batteries is
excluded.
•
Two Battery Charging Ports: Automatic charging of the main battery or leisure battery. Support charging and trickle
charging of the vehicle's starter battery with overcharge protection.
•
Unattended Charging: Standard protection against back discharge of battery (in case of insufficient solar power (such
as at twilight, at night etc.) and against overload and overheating.
•
Floating Operation: Observation of the characteristic lines of charging, even with simultaneous operation of
consumers being connected to the battery.
•
Overcharge protection: Reduction of the charging current of the battery in case of excessive solar power and full
battery. Immediate recharging in case of power consumption to ensure always the best possible charging state of the
battery.
•
Characteristic Line of Charging "IU1oU2": A defined charging boost (U1) avoids harmful acid accumulation and
provides compensation charge to the individual battery cells. After that, automatic trickle charging (U2).
•
On-board Mains Suppression Filter: Integrated on-board mains suppression filter ensures unproblematic parallel
operation of the controller with other charging sources, wind- and petrol-driven generators, mains supply chargers,
dynamos etc. at one battery.
•
Connection for Temperature Sensor:Automatic adaptation of the charging voltage to the battery temperature. In
case of low outside temperatures, full charging of the weaker battery is improved, and in case of summery
temperatures unnecessary battery gassing will be avoided.
This is highly recommended, if the battery is exposed to strong variations in temperature, such as in the motor
compartment.
•
Charging Cable Compensation: Automatic compensation of voltage losses on the charging cables.
•
Measurement Output for EBL (Electroblock of the Vehicle): Allows convenient application of the (solar) current
display being installed in the electroblock for supervision of the solar system.

- 2 -
•
Terminal „AES“ (only SR 350 Duo Dig. and SR 550 Duo Dig.):
Automatic commutation of ELECTROLUX/DOMETIC refrigerators with “AES” (Automatic Energy Selector) from gas
operation to 12 V operation in case of excess solar power.
•
Ready for connection of the VOTRONIC Solar Displays for optimum control of the system:
LCD Solar Computer S: The LCD display indicates the following values: Battery voltage, charging current,
charging capacity, stored capacity and energy (V, A, W, Ah, Wh).
Open acid batteries and batteries being "maintenance-free according to EN / DIN":
Check the acid level periodically!
Recharge totally discharged batteries immediately!
Store only fully charged batteries and recharge them periodically!
Safety Regulations and Appropriate Application:
The solar controller has been designed according to the valid safety regulations.
Appropriate application is restricted to:
1.
Charging of lead-gel, lead-AGM, lead-acid-batteries of the indicated nominal voltage and simultaneous
supply of the consumers being connected to these batteries in fixed installed systems.
2.
Solar panels up to the maximum power rating (Wp) and max. panel voltage (Voc) of the used solar
controller.
3.
The indicated cable cross sections at the charging ports and at the panel input.
4.
With fuses of the indicated capacity near the battery to protect the cabling between battery and charging
ports.
5.
Technically faultless condition.
6.
Installation in a well-ventilated room, protected from rain, humidity, dust, aggressive battery gas, as well as
in an environment being free from condensation water.
7.
The device must not be operated on the input terminals "+/-solar panels" with wind, water, fuel or motor
generators, power supplies, batteries or other power sources!
•
Never use the unit at locations where the risk of gas or dust explosion exists!
•
Cables are always to be laid in such a way that damage is excluded. Observe to fasten them tightly.
•
The connection cables have always to be led from below to the solar controller to ensure that penetrating
humidity cannot reach the controller in case of failure, which will result in destruction of the controller.
•
Never lay 12 V (24 V) cables and 230 V mains supply cables into the same cable conduit (empty conduit).
•
Check live cables or leads periodically for insulation faults, points of break or loosened connections. Occurring
defects must be remedied immediately.
•
The unit is to be disconnected from any connection prior to execution of electrically welding or work on the
electric system.
•
If the non-commercial end-user is not able to recognize the characteristic values being valid for a unit or the
regulations to be observed, a specialist is always to be consulted.
•
The user/buyer is obliged to observe any construction and safety regulations.
•
Except for the fuse, the unit is not equipped with parts, which can be replaced by the user.
Always use replacement car fuses of the indicated capacity!
•
Keep children away from the solar controller and the batteries.
•
Observe the safety regulations of the battery manufacturer.
•
Deaerate the battery room. Protect the unit from aggressive battery gases.
•
Ensure sufficient ventilation of unit and panel!
•
Strictly observe the instructions of the manufacturer for installation of the solar panel.
•
Non-observance may result in injury or material damage.
•
The warranty period is 36 months from the purchase date (against presentation of the sales slip or invoice).
•
The guarantee will be void in case of any inappropriate utilisation of the unit, if it is used beyond the technical
specification, in case of improper operation, intrusion of water or external intervention. We do not assume any
liability for any damage resulting hereof. The liability exclusion is extended to any service being executed by third,
which has not been ordered by us in writing. Service is to be effected exclusively by VOTRONIC, Lauterbach.

- 3 -
Connection
Plan:
Note:
The connection plan shows the maximum terminal assignment for operation of all existing functions of the solar
controller. The minimum terminal assignment consists of the solar panel inputs ("+" and "-") and the connections of
the main battery.
Always connect the fuses as close as possible to the batteries (cable protection!).
Required Cable Cross Sections, Notes SR 150 Duo Dig. SR 230 Duo Dig. SR 350 Duo Dig. SR 550 Duo Dig.
+/- Panel cables, length as required
2.5-4 mm2
4-6 mm2
6-10 mm2
10-16 mm2
+/- Battery cables, length max. 2 m
2.5-4 mm2
4-6 mm2
6-10 mm2
10-16 mm2
Fuse close to main battery
15 A
20 A
30 A
40 A
Cut-off Relay:
The cut-off relay, which exists in most of the vehicles, can, of course, still be used. (For charging by the
dynamo, the cut-off relay connects the board battery to the starter battery during running motor of the
vehicle. The cut-off relay is not included in the connection plan).

- 4 -
Mounting:
Screw-down the solar controller on an even and hard mounting surface at locations being protected from humidity and
near the main/leisure battery to ensure that the length of the battery's connection cable is as short as possible.
Vertical installation of the controller is highly recommendable (the terminals for solar panel and batteries point down).
This mode of installation improves cooling of the unit and avoids that water runs along the connection cables of the solar
panel into the solar controller, even in case of damaged seals.
If used, the cable to the starter battery can be longer.
Despite the solar controller's high efficiency, heat is produced. Ensure sufficient ventilation in the environment of the unit,
so that the heat can be carried-off.
The unit might heat-up. Consequently, the vent holes of the casing should never be covered to ensure full charging capacity
(minimum distance all around: 10 cm).
Connection(See Connection Plan):
The polarities (+ and -) of solar panel and batteries are absolutely to be observed!
Observe the cross-sections and length measures of the cables!
1. Connection of the solar controller to the main/leisure battery should be effected first.
Cable Protection:
Insert the fuses near the batteries into the + cables (protection against cable fire)!
2. The solar panels should be protected from direct sunlight (by covering or shading)
prior to connection.
1.) Main/Leisure Battery (must be connected):
Connect the battery connections of the controller - (Minus) and + (Plus) to the 12 V main battery, observing the correct
polarity and the cross section of the cables (refer to connection plan).
Never operate the controller without the battery main/leisure battery.If the battery is not connected, the unit will not
deliver a defined output voltage.
In case of wrong polarity of the battery, the internal safety fuse will be released.
The replacement fuse should have the same capacity, and it should be of the same type (car fuse)!
Parallel charging of two or several batteries of the same voltage (12 V) is admissible. The batteries are to be "paralleled",
i. e. the "+" connections of the batteries have to be coupled and should be connected to the "+" connection of the solar
controller. The minus (-) connections have to be coupled in the same way.
According to the battery manufacturers, permanent parallel operation is admissible in case of two or several batteries of
the same voltage, type, capacity, as well as of the same age (history) in cross connection.
2.) Solar Panel (must be connected):
Shade the panels to minimize sparking during connection.
Observe the cable cross-sections (refer to connection plan)!
If several small solar panels are used, they are connected in parallel (refer to connection plan). Partial shading of the panels
results in average higher capacity (see connection plan).
The (-) minus connection of the solar panels may only be connected to the (-) minus terminal of the solar
controller!
A further connection (possibly from the connection of a previous solar controller, damaged insulation at the
roof cable gland or similar) to battery minus (-) or to the vehicle (-) chassis could falsify the internal current
measurement of the unit and must not exist.

- 5 -
3.) Starter Battery "START" (Option, can be connected):
Connect the second charging port to the second battery using the red connection cable (wire cross section 1.5 - 2.5 mm²).
This cable may be longer. In case of non-utilization, this terminal is left free.
If used, the output for starter battery will be working with reduced voltage and charging current rates. Thus, the valuable
solar power will be supplied to board/leisure battery being more suitable.
However, the vehicles starter battery will be kept in a condition, that starting will always be possible, even in case of longer
downtimes and during winter operation.
Connection of the negative pole "START" is not required, if the negative pole of the main/ leisure battery is
connected to the vehicle body. Depending on the length of the cable, it may also be connected to the common
negative connection of the solar controller or to the negative pole of main/leisure battery.
4.) Plug-type Connection "Solar Display" (Option, can be connected):
6-
pole tip jack for connection of the VOTRONIC Solar Displays being ready for connection for optimum control of the solar
system:
LCD Solar Computer S: The LCD display indicates the following values: Battery voltage, charging current, charging
capacity, stored capacity and energy (V, A, W, Ah, Wh). (Order No.: 1250)
5.) "EBL" Connection for Electroblock with Display Panel DT… / LT... (Option, can be connected):
A cable set for connection of the solar controller to the EBL is required. Order No.: 2007 (It is not included in the standard
delivery scope of the controller).
The solar controller supplies a signal at the terminal "EBL" for display of the solar charging current, which is suitable for
electroblock EBL… with DT…/LT… Display Panel.
The signal cable being required for that, as well as a connection cable for connection of the solar controller to the EBL are
included in the set of EBL connection cables.
6.) "AES" (Automatic Energy Selector) only SR 350 Duo Dig. and SR 550 Duo Dig.
(Option, can be connected):
The delivery scope of DOMETIC/ELECTROLUX includes refrigerators with all-automatic energy selection (230 V AC, 12 V DC
or gas).
Particularly in summer, a lot of excess energy might be produced due to strong solar radiation, full batteries and low energy
consumption, which is left unused. The solar controller recognizes this condition and uses the "AES" output to give a signal to
the refrigerator, which will commutate from gas operation to 12 V operation to benefit from the excess energy (gas
saving).
Connection:
Lead a single-pole cable (0.5-1.5 mm²) from the solar controller's terminal "AES" to the refrigerator's terminal "T10".
Function:
The solar controller recognizes the excess capacity (LED "AES" is lighting). The refrigerator switches from gas operation to
12 V operation. This mode will be kept for at least half an hour to avoid that the refrigerator will be “swinging” between
12 V operation and gas operation.
Should the solar power be still sufficient, the 12 V operation of the refrigerator will be kept.
Should the solar power be insufficient, "AES" will be switched off by the solar controller, the refrigerator will be switched to
gas operation, it will keep this mode for at least half an hour, and the solar power will be used for recharge of the (possibly
slightly discharged) battery. This mode of operation can only be taken into account in case of sufficient efficiency of the
solar panel and under favourable conditions, such as 110 Wp, better 150 Wp or more.
Option:
Optionally, small 12 V consumers can be operated at the AES output, such as 12 V fans, car relays or refrigerators with
control input D+ (Thetford etc.). It must be observed, that the output must be active for at least half an hour.
The output current of the terminal "AES" is max. 200 mA. In case of larger consumers the output is limited and
can again be loaded after a cooling down phase.

- 6 -
7.) Temperature Sensor, Input "TS TS" (Option, can connected):
Connection for the external Votronic Temperature Sensor 825, order No. 2001 (is not included in the standard delivery
scope).
For automatic adaptation and correction of the charging voltage to the battery temperature (temperature compensation).
Mounting:
The thermal contact of sensor and the battery (inside temperature) should be well. Thus, it should be screwed down to the
negative pole or positive pole of the battery. It is also possible to fasten it at the sidewall centre of the battery casing.
Ensure that the installation place is not influenced by any source of heat (motor block, exhaust, heater etc.).
Connection:
Connect the temperature sensor to the terminal. The polarity and cable length is of no importance.
The solar controller recognizes the sensor automatically.
Effect:
The temperature-dependent charging voltage of the battery will be adapted automatically to the battery temperature.
The temperature sensor measures the battery temperature. In case of low temperatures (winter operation), the charging
voltage will be increased in order to improve and accelerate full charging of the weak battery. Sensitive consumers are
protected by a limitation of the voltage in case of very low outside temperatures. In case of summery temperatures, the
charging voltage is reduced to minimize the load (gassing) of the battery and to extend the lifetime of gas-tight batteries.
(See "Charging Voltage Rates and Temperature Compensation of Main/Leisure Battery" on page 10).
Safety Mode:
Battery Protection:
(also see characteristic lines: "Charging Voltage Rates and Temperature Compensation of Main/Leisure Battery"):
In case of too low battery temperatures or too high battery temperatures (from +50 °C), the charging voltage will be
reduced strongly to safety charging voltage for battery protection (depending on the type from 12.75 V to 13.00 V). Safety
mode, LED "Bulk" is flashing, but any charging data being recorded hitherto will be kept in memory.
Battery charging is then interrupted, but the supply of eventually connected consumers will be continued by the solar
controller, and the battery can cool down. As soon as the battery temperature reaches the admissible range again,
automatic charging will be continued.
The solar controller recognizes automatically a missing sensor, cable break or short-circuit of the sensor lines, as
well as unreasonable measuring values. In that case, it will switch automatically to the usual charging voltage
rates of 20 °C / 25 °C being recommended by the battery manufacturers.

- 7 -
Pilot Lamps:
"AES" (excess power display, only SR 330 Duo Dig. and SR 530 Duo Dig. green):
•
If it is lighting: Sufficient excess solar power, the output "AES" for automatic energy selection of the refrigerator
or of a consumer is activated.
•
Off:
Output "AES" is switched-off.
"Float" (Battery fully charged, green):
•
If it is lighting: Battery (batteries) has (have) been charged to 100 %, trickle charge U2, finished.
•
If it is lighting dimly: Main charging process is still effected in the charging phase U1.
•
Off:
Main charging process is still effected in the charging phase I.
"Absorb” (green):
•
If it is lighting: Battery has been charged almost fully. Solar controller is still in the charging phase U1.
"Bulk" (green):
•
If it is lighting: Brightness from slight dimly lighting up to full brightness indicates the charging current intensity.
•
Off:
Solar power is insufficient.
•
If it is flashing: Safety mode battery protection: Battery temperature < -30 °C or overtemperature > +50 °C
•
If it is flashing 1x:Disconnection of solar overvoltage: LED "Bulk" is flashing 1 x. After that, the controller changes
to stand-by. Imperatively check the voltage (Voc) of the solar module!
"Standby" (only SR 150 Duo Dig. and SR 230 Duo Dig. green):
•
If it is flashing: The controller is in stand-by mode, if solar current is not available (at night).
"Batt. Low" (yellow):
•
If it is lighting: Low voltage at main battery I. The battery should be recharged as soon as possible!
All light-emitting diodes are flashing simultaneously:
•
The positions of the selector switches for the main/leisure battery are incorrect. For reasons of safety, the solar
controller is switched-off. Adjust the desired battery type according to table 1.
Operating Instructions:
•
Lifetime of the battery:
•
Recharge totally discharged batteries immediately!
Sulphation of the lead battery plates due to total discharge is to be prevented by soon charging, particularly in case
of high ambient temperatures. If the grade of sulphation is not too intensive, the battery can recover part of the
battery capacity after several charging/discharging cycles.
•
Partially Discharged Batteries:
In contrast to other battery types, batteries on lead basis do not have any harmful memory effect. Consequently: In
case of doubt, partially discharged batteries have to be charged fully as soon as possible.
Always store only fully charged batteries. Recharge them periodically, particularly in case of used (older) batteries
and higher temperatures.
•
Keep batteries cool and dry; choose an appropriate location for installation.
•
In case of insufficient solar power and/or high current consumption, the battery should be subject to occasional
full charging by means of a mains supply charger.
•
Overvoltage Protection:
The 12 V solar controllers protect themselves against connection of excessive battery voltage rates or will be switched-
off in case of defective additional charging systems (chargers, generators or similar systems), switching threshold 15.0-
16.0 V.
•
Overvoltage Limitation:
Sensitive consumers are protected by means of a limitation of the charging voltage to max. 15.0 V during all modes of
charging.
•
Overload/Overheating Protection Solar Controller: The solar controller is equipped with a double electronic protection
against overload and with an automatic protection against adverse installation conditions (e. g. insufficient ventilation,
excessive ambient temperatures) by gradual reduction of the charging capacity.
•
Voltage Measurement: Measurement of the voltage is to be effected at the battery and never at the solar controller
(loss at the charging cable).
In case of unattended operation, the battery might be totally discharged due to too many consumers and lack
of solar power. We recommend protecting the battery by means of the following appliances:
Votronic Battery Protector 40 (Power rating 12 V/40 A) Order No. 3075 or
Votronic Battery Protector 100 (Power rating 12 V/100 A) Order No. 3078

- 8 -
Table 1: For Main Battery: How to set the correct charging program for the battery
type
Prior to start-up, imperatively set the correct characteristic line of charging being suitable for the
battery to avoid battery damages!
Set the slide switch ("Battery Type") to the desired position for main battery using a small screwdriver.
Switch "1" must remain in the below position.
After that, select the desired characteristic line of charging using the switches "2", "3" and "4" as indicated in the tables:
"Gel": Charging program for gel/dryfit batteries:
Adapted to closed, gas-tight Gel batteries with determined electrolytes, which are generally requiring a
higher charging voltage level and longer dwell times U1 to achieve short charging times with particularly
high capacity storage and to avoid total discharge, e. g. EXIDE, Sonnenschein dryfit- Start, Dryfit-Sport-
Line, DETA Gel Battery Funline, Bosch AS Gel Batteries Va/Z, AS Gel Drive Batteries, AS Gel Lighting
Batteries.
If not being specified divergently by the battery manufacturer, also recommended for batteries in round
cell technology, such as EXIDE MAXXIMA (DC).
EXIDE, DETA, VARTA Characteristic Line Gel IU1oU2
U1 = Main/Full Charging:
U2 = Full/Trickle/Storage Charging:
Safety mode for battery overtemperature:
:
14.30 V
13.80 V
12.75 V
+20 °C
+20 °C
> +50 °C
3-10 h
Continuous
"Lead Acid/AGM1": Charging program for acid/lead-acid batteries as well as AGM 14.4 V:
For charging and trickle charge of supply batteries. Ensures short charging times, high charging factor and
acid mixing for open standard batteries and closed, low-maintenance, maintenance-free "non-solid
electrolyte", "lead-acid", drive, lighting, solar and heavy duty batteries. Also suitable for recently developed
batteries (low-antimonous, batteries with silver-alloy, calcium/calcium or similar) and batteries with
low and very low water consumption, as well as
AGM batteries with the indication 14.4 V.
Characteristic line of charging IU1oU2 Acid/AGM:
U1 Main/Full Charging:
U2 Full/Trickle/Storage Charging:
Safety mode for battery overtemperature:
14.40 V
13.45 V
12.80 V
+20 °C
+20 °C
> +50 °C
1.5-6 h
Continuous
"AGM2": Charging Program for AGM/fleece Batteries 14.7 V:
Adapted to closed, gas-tight AGM (absorbed glass mat) batteries and batteries in lead-fleece technology,
Lead Crystal, VRLA, requiring a particularly high level U1 for full charging.
ATTENTION: It is highly recommended to check the specification sheet of the battery concerning the high
charging voltage U1 14.7 V.
Unsuitable batteries might age prematurely due to loss of electrolyte!
Some manufacturers of AGM/fleece batteries are also prescribing a 14.4 V charging program for charging!
In these cases, please set "Lead Acid/AGM1" (14.4 V / 13.45 V).
Characteristic Line AGM/Fleece IU1oU2:
U1 Main/Full Charging:
U2 Full/Trickle/Storage Charging:
Safety mode for battery overtemperature:
14.70 V (!)
13.50 V
12.75 V
+20 °C
+20 °C
> +50 °C
1.5-5 h
Continuous
Not used. All LEDs are flashing, and the charging port is switched-off by the solar controller.
These and other switch positions are not valid and are not used (service positions)!
Further actions at the unit are not required during normal automatic mode.

- 9 -
Charging Voltage Rates and Temperature Compensation of Main/Leisure Battery:
Lead Batteries:
Charging Program "Lead Acid/AGM1", Characteristic Line IU1oU2 Charging Program "AGM2", Characteristic Line IU1oU2
Charging Program "Gel", Characteristic Line IU1oU2
TS = If a temperature sensor is used

- 10 -
Functions (at the Main/Leisure Battery):
If solar power is missing (at night), readiness for service of the controller will be indicated by short flashing of the LED
(light-emitting diode) "Bulk".
SR 150 Duo Dig. and 230 Duo Dig.: In any operating state, a totally discharged battery is indicated by means of the LED
"Batt. Low" (low voltage). Now the battery has to be recharged as soon as possible (disconnect the consumers)!
SR 350 Duo Dig. and 535 Duo Dig.: The LED "AES" will be lighting in case of excess solar power, output "AES" is active.
An evenly flashing LED "Bulk" indicates a possible failure in the system: Controller overheated or failure found during self-
test, battery too hot (>50 °C) when using the battery temperature sensor.
As soon as the solar power is again sufficient, the LED "Bulk" will be lighting and the charging process starts.
At the same time, the brightness of the LED "Bulk" is a measure for the converted solar power: The brighter, the more of
the existing (also little) solar power will be supplied.
1.
Maximum charging current (Phase I) in the lower and mean voltage range of the battery up to the beginning of the
phase U1. The total solar power will be supplied to the battery for quick charging. During the phase I, charging will
be effected up to approx. 75 to 80 % charging state.
2.
During the following phase U1 the battery voltage will be kept constant on a high level close to the gassing limit, the
battery determines the charging current according to its charging state, the high battery capacity will be charged and
the LED "Absorb" is lighting.
The solar controller will control the charging time as well as the charging voltage and will switch automatically to the
following phase U2=trickle charge. If the battery has already been charged fully, the charging time will be reduced
accordingly.
3.
During the phase U2 (Full charging/trickle charge) the battery will be kept on its charging level. Only the
compensating recharging current is flowing being required for conservation of the full charge, which is determined
by the battery. The duration of that phase is not limited, the LED "Float" is lighting intensively.
4.
Now, almost the entire solar current is available to the consumers.
Switching back to the phase I or U1 is effected, if the battery had been subject to load for an extended period, or if the solar
controller switches to stand-by mode after sunset.
If a temperature sensor is used for the battery, the voltage values will be slightly higher in case of low outside
temperatures, while they will be slightly lower in case of high outside temperatures.
The output for the starter battery (START) will be working with reduced voltage and charging current rates. Thus, the
valuable solar power will be supplied to board/solar battery being more suitable. However, the starter battery will be kept
in a condition, that starting will always be possible, even in case of longer stop periods (e. g. in winter).
Charging Process (Characteristic Line of Charging IU1oU2) at the Main/Leisure Battery in Case of Sufficient
Solar Power:
1.
Preliminary charging of totally discharged battery, gentle initial charging current (I-Phase)
2.
Main charging constant, maximum charging current (I-Phase)
3.
Main/full charging constant charging voltage 1 (U1-Phase)
4.
Full/Trickle charge constant continuous charging voltage 2 (Phase U2)

- 11 -
Notes:
Declaration of Conformity:
In accordance with the provisions of the statutory requirements and the relevant directives, Electrical
Equipment (Safety) Regulations 2016, Electromagnetic Compatibility Regulations 2016, The Restriction of
the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 this
product complies with the following standards or normative documents:
BS EN55014-1; BS EN61000-6-1; BS EN61000-4-2; BS EN61000-4-3; BS EN61000-4-4; BS EN62368-1;
BS EN50498, BS EN IEC 63000.
Recycling:
At the end of its useful life, you can send us this device for professional disposal:
You can find more information about this on our website at www.votronic.de/recycling

- 12 -
Ambient Conditions, Humidity of Air:
-20°C ... +45 °C max. 95 % RH, no condensation
Technical Data: SR 150 Duo
Digital
SR 230 Duo
Digital
SR 350 Duo
Digital
SR 550 Duo
Digital
Capacity of Solar Module (recommended/max.):
Current Solar Module:
Voltage Solar Module (Voc):
30 - 150 Wp
0 - 9.5 A
max. 28 V
40 - 230 Wp
0 - 14.5 A
max. 28 V
50 - 350 Wp
0 - 22.0 A
max. 28 V
50 - 550 Wp
0 - 35.0 A
max. 28 V
Nominal Voltages of Batteries Main/Leisure and Starter:
Charging Current:
Current Consumption Stand-by (max.):
12 V
0 - 9.5 A
4 mA
12 V
0 - 14.5 A
4 mA
12 V
0 - 22.0 A
4 mA
12 V
0 - 35.0 A
4 mA
Main Port of Main Battery:
Charging/Floating/Load Current:
0 - 9.5 A
0 - 14.5 A
0 - 22.0 A
0 - 35.0 A
Max. Prelim. Charg. Current (totally discharged battery):
Reset Voltage (30 sec):
4.5 A (<8 V)
12.7 V
7.0 A (<8 V)
12.7 V
10.5 A (<8 V)
12.7 V
16.5 A (<8 V)
12.7 V
Charging Programs for Gel/AGM/Acid Batteries:
Charging Voltage Limitation (max.):
Integrated Overload Protection (Current Limiting Device):
Integrated Protection against Short-circuit:
Integrated Protection against Overtemperature:
Integrated Cooling Fan with Temp. Control:
Unit Fuse (Type FKS):
Input for Battery Temperature Sensor:
Charging Timer:
3
15.0 V
Yes
Yes
Yes
-
15 A
Yes
3-fold
3
15.0 V
Yes
Yes
Yes
-
20 A
Yes
3-fold
3
15.0 V
Yes
Yes
Yes
Yes
30 A
Yes
4-fold
3
15.0 V
Yes
Yes
Yes
Yes
40 A
Yes
4-fold
Refrigerator Control Output "AES":
Switching Current Control Output "AES" max.:
-
--
-
--
Yes
12 V/0.2 A
Yes
12 V/0.2A
Signal Output "EBL" for Display "Solar" Charging Current: Yes Yes Yes Yes
Auxiliary Port Vehicle Starter (Start):
Charging Current:
0 - 0.8 A
0 - 0.8 A
0 - 1.5 A
0 - 1.5 A
Integrated Overload Protection (Current limiting device):
Integrated Protection against Short-circuit:
Integrated Protection against Overtemperature:
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Dimensions, incl. Mounting Flanges (mm):
Weight:
131 x 77 x 40
150 g
131 x 77 x 40
155 g
131 x 77 x 40
165 g
131 x 77 x 40
170 g
Declaration of Conformity:
In accordance with the provisions of Directives 2014/35/EU, 2014/30/EU, 2009/19/EC, this
product complies with the following standards or normative documents:
EN55014-1; EN55022 B; EN61000-6-1; EN61000-4-2; EN61000-4-3; EN61000-4-4;
EN62368-1; EN50498.
The product
must not be
disposed of in
the household
waste.
The product is RoHS compliant.
It complies with the directive
2015/863/EU for Reduction of
Hazardous Substances in electrical
and electronic equipment.
Delivery Scope: Available Accessories:
•
Solar Controller
•
Operating Manual
•
Temperature Sensor 825
•
LCD Solar Computer S
•
Cable set for connection of the solar controller to
the EBL
Order No. 2001
Order No. 1250
Order No. 2007
Subject to misprints, errors and technical modification without notice.
All rights reserved. This material may not be published, broadcast, rewritten or redistributed in whole or part without the
express written consent of the manufacturer. Copyright © VOTRONIC 02/2023.
Made in Germany by VOTRONIC Elektronik-Systeme GmbH, Johann-Friedrich-Diehm-Str. 2, 36341 Lauterbach/GERMANY
Phone: +49 (0)6641/91173-0 Fax: +49 (0)6641/91173-10 E-Mail: info@votronic.de Internet: www.votronic.de
This manual suits for next models
7
Table of contents
Other Votronic Controllers manuals
Popular Controllers manuals by other brands

WEISS
WEISS ER12D-1 Installation & operation instructions

Matelec
Matelec FPC-15207 Owner's operation manual

Novar
Novar 315 Commissioning instructions

NEC
NEC N8803-032 user guide

Extron electronics
Extron electronics Basic MediaLink Controllers MLC 52 RS Specifications

Spectron
Spectron Spectrolab LM71 user manual

Ultraflex
Ultraflex SUPERMASTER 24 Vdc user manual

Emerson
Emerson Hytork XL26 Installation, operation & maintenance manual

United Automation
United Automation INFRESCO P user manual

Emerson
Emerson Dixell XR70CX Installing and operating instructions

Desoutter
Desoutter CVIC II manual

Dontek
Dontek H7 SV instructions