Vroom Spot User manual

Installation Instructions
●New Construction
●Retrofit
Operating Instructions
Warranty

Installation
Valve Location
Spot is designed for quick-clean jobs in mess prone areas.
It is perfect in laundry rooms, pet areas and foyers. When
determining valve placement, consider the most effective
placement for the 10’ reach of the hose.
Example: In the laundry room, install the valve at a height that is
convenient for cleaning the dryer vent based on the vent location.
The valve can be installed so the hose retracts up or down.
In some installations the hose retraction may interfere with
the on/off switch and turn the system off unexpectedly.
This can be avoided by repositioning the valve so the hose
pulls away from the switch for most uses.
Note: The hose is stored in the tubing and needs to be in a
vertical position for best performance when pulling out/
retracting in. The compressed hose is 30” long. A tight 90
degree elbow installed 32” from the valve will prevent the
retracting hose from expanding and being pulled into the
horizontal tubing.
New Construction Rough-In
Attach the frame to the stud.
Determine the best location for the
valve and attach to the stud. Be certain
the final location allows for 32” of tubing
for hose storage. Make sure the frame
is level.
Kit Includes:
• Pipe Fitting
• Rough-In Frame
• Mud Cover
Rough-In Kit (P/N HS3000R)

New Construction Rough-In
Insert the pipe fitting.
The rough-in frame contains a “U-
shaped” bracket. Slide the grooved end
of the pipe fitting into U-shaped bracket.
The bracket and fitting slide to allow
adjustment for variations in wall board
thickness.
NOTE: Valves can be used with a
maximum wall thickness of ¾″. Thicker
walls may require modification.
Install the pipe into the fitting.
Glue the pipe into the fitting, making
sure it seats all the way to the ridge of
the pipe fitting.
Low-Voltage Wire
Run low-voltage wire to each inlet just
as you would with a standard central
vacuum install. Secure low-voltage wire
to pipe at the base of fitting. Allow 12″
of slack wire and tuck back into pipe.
Install the mud cover.

Retrofitting an
Existing Home
Use the mud cover
as a template to cut
the hole.
Insert the rough-in frame
To get the frame through the cut
hole, turn it sideways. Angle
through the hole and once behind
the drywall turn the frame to a
vertical position.
Depending on how close you are
to a stud, you may need to score
and cut off one or both of the
mounting tabs.
Push the bottom two pointed
tabs into the sheet rock. The top
pointed tab can be bent down as
you pull the top of the frame into
the hole. The tabs will help hold
the frame into place while you
install the valve. You may need
to use small finish nails horizontally
on the side of the frame to secure
the mounting bracket until the valve
is installed.
Side Frame
Holes

The pointed tabs
are used to secure the
frame to the sheetrock
while you install the valve.
With new construction, it is
likely that these tabs will
be cut off by the sheetrock
installers.
It may be helpful to
push small finish nails
horizontally into the sheet
rock through the holes in
the side of the frame to
secure plate until the valve
is installed.
Apply a silicone
based lubricant to
the O-ring. (Included)
Trim
Pointed Tabs
Pointed Tab
Side Frame
Holes
O-Ring
Trim Kit
Kit Includes:
• Valve Assembly
• Snap-on Door

Insert the valve assembly
into the rough-in frame.
Secure valve to frame by
aligning the four holes in the
valve assembly with the holes in
the frame. Secure with the four
screws included with the trim kit.
Low-Voltage Wire
Use wire nuts to connect the low
voltage wire to the two leads on
the reed switch (located on the
outside of the valve).
Install the door
by lining up the door
and valve hinge, then
press it into place.
Installed Valve Assembly
and Door
Reed
Leads

Usage
Using Spot
Spot is the ultimate central vacuum accessory. It
harnesses the airflow from your central vacuum system to
deliver on-the-spot cleaning.
To use your Spot:
1. Lift the cover.
2. Pull out the retractable hose.
3. Pull out the red tab to turn on the vacuum power.
4. Vacuum the dry mess.
5. Walk hose back toward valve. The hose will start to
automatically retract. (NOTE: If your hose does not
retract, place your hand over the nozzle to stop the
airflow and it will pull back into the valve.)
6. Push the red tab to turn off vacuum power.
7. Close the cover.
Spot is manufactured by H-P Products,Inc. 512W. Gorgas Street,
Louisville, Ohio, 44641
www.spotbyvroom.com
Cover
Retractable Hose
Red Power Tab

H-P Products, Inc. warrants that the Spot Hose and Valve,
when used for household purposes, pursuant to seller’s
instructions, will be free from defects in materials and
workmanship for a period of three (3) years from the date of the
initial consumer purchase. H-P Products, Inc. warrants the
above mentioned products when used in a commercial
application to be free from defects in materials and
workmanship for a period of ninety (90) days from the date of
the initial purchase. This warranty is limited to the replacement
of defective parts and any costs of shipping shall be incurred by
the purchaser. THIS WARRANTY IS A SOLE AND
EXCLUSIVE WARRANTY. ALL OTHER WARRANTIES
INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ARE
EXCLUDED. THIS WARRANTY COVERS ONLY LIABILITY
AND RESPONSIBILITY DESCRIBED HEREIN AND THERE IS
NO LIABILITY FOR ANY CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES ARISING FROM THE USE OF THIS
SYSTEM.
Some states do not allow the exclusion or limitation of
warranties or limitation of incidental or consequential damages
so the above exclusion my not apply to you. This warranty give
you specific legal rights and you may have other rights that vary
from state to state.
Limited Warranty
PL-193
Table of contents
Other Vroom Vacuum Cleaner manuals