WAGNER TITANUS PRO-SENS User manual

Air Sampling Smoke Detection System
®
TITANUS PRO·SENS
Technical Manual


Air Sampling Smoke Detection System
TITANUS PRO·SENS®
P
Technical Manual
WAGNER Group GmbH
Schleswigstraße 1 - 5
D-30853 Langenhagen
Telephone +49 (0) 511 / 97383-0
Telefax +49 (0) 511 / 97383-140
Internet www.wagner.de
item number:
dated:
supersedes:
69-30-0226
04/09
06/06


Contents TITANUS PRO·SENS®
Data: 04/09 PS-Inhalt-a_en_e
Contents
0 General 0 – 1
0.1 Introduction 1
0.2 Safety Information 1
0.3 Guarantee 2
0.4 Copyright 2
0.5 Packaging 3
0.6 Disposal 3
1Product Description 1 – 1
1.1 Features of the TITANUS PRO·SENS®
air sampling smoke detection system 1
1.2 Areas of Application 3
2Technical Description 2 – 1
2.1 System Description 1
2.1.1 Function 2
2.2 TITANUS PRO·SENS®and Accessories 5
2.2.1 Overview 5
2.2.2 Basic Device TITANUS PRO·SENS®6
2.2.3 Diagnostics 8
2.2.4 Response Indicators 9
2.2.5 Device Support 10
2.3 Pipe system 11
2.3.1 Overview of available pipe components 11
2.3.2 Air sampling points for room monitoring 13
2.3.2.1 Aspiration-reducing film sheets 13
2.3.2.2 Air flow reducer clips 14
2.3.3 Ceiling feed-through for hidden installations 15
2.3.4 Air filter for dusty areas 17
2.3.5 Air return for pressurised and dusty areas 18
2.3.6 Noise suppressor 19
2.3.7 Steam trap for humid areas 20
2.3.8 Detonation prevention device for endangered areas 21

TITANUS PRO · SENS®Inhalt
PS-Inhalt-a_en_e Data: 04/09
Contents
3Technical Data 3 – 1
3.1 TITANUS PRO·SENS®1
3.2 Pipe system – TITANUS PRO·SENS®5
4Design 4 – 1
4.1 General 1
4.1.1 Regulations 2
4.1.2 Pipe system 3
4.1.3 Air flow monitoring 7
4.1.4 Sensitivity 9
4.1.5 Project planning limits 10
4.2 Project planning 11
4.2.1 Project planning guidelines 11
4.2.1.1 Determining the necessary accessories 11
4.2.2 Pipe accessories 12
4.2.3 Sensitivity and pipeline project planning 13
4.2.3.1 Pipeline project planning with pipe accessories 13
4.2.4 Aperture diameter 17
4.3 Special project planning 20
4.3.1 Project planning for individual aperture monitoring 20
4.3.1.1 I-pipe system 20
4.3.1.2 U-shape pipe system 22
4.3.1.3 M-pipe system 24
4.3.1.4 Double U-pipe system 26
4.3.2 Simplified pipe project planning 28
4.3.2.1 I-pipe system 28
4.3.2.2 U-pipe system 29
4.3.2.3 M-pipe system 30
4.3.2.4 Double U-pipe system 31
4.3.3 Project planning with long intake lines 32
4.3.4 Project planning with acceleration apertures 33
4.3.5 Project planning for forced air flow 36
4.4 Mains supply 40
5Installation TITANUS PRO·SENS®5 – 1
5.1 General 1
5.2 Opening the TITANUS PRO·SENS®air sampling system 2
5.3 Settings 3
5.3.1 Detector module 3
5.3.1.1 Setting of the response sensitivity 3
5.3.1.2 Delay period of the alarm activation 4
5.3.1.3 Activating threshold of the air flow monitoring 4
5.3.1.4 Delay period of the air flow fault 5
5.3.1.5 Fault display 5

Contents TITANUS PRO·SENS®
Data: 04/09 PS-Inhalt-a_en_e
Contents
5.3.1.6 LOGIC·SENS 5
5.3.1.7 Function of the collective fault contact 6
5.3.1.8 Setting of the Ventilator Voltage 7
5.3.1.9 Connecting the ventilator 8
5.3.1.10 Setting of ventilator voltage at TITANUS PRO·SENS®-SL 9
5.3.1.11 Connecting the ventilator i TITANUS PRO ·SENS ® -SL 12
5.4 Installation of the reset board 13
5.5 Mounting Location 14
5.5.1 Fixing of the air sampling system TITANUS PRO·SENS®14
5.5.2 Connection of the air sampling pipe 16
5.6 Electrical connection 17
5.6.1 Connection to central fire panel, with reset button 18
5.6.2 Connection of several TITANUS PRO·SENS® without
central fire panel, with reset button 19
5.6.3 Connection to central fire panel, with reset board 20
5.7 Application of TITANUS PRO·SENS®in the
smoke detection system AlgoRex®21
5.7.1 Potential-free connection 21
5.7.1.1 Potential-free connection diagram 22
5.7.2 Application of TITANUS PRO·SENS®with AlgoRex®
line modules 23
5.7.2.1 Installation of AlgoRex®line modules in the
TITANUS PRO·SENS®housing 23
5.7.2.2 TITANUS PRO·SENS®and AnalogPLUS-technology 25
5.7.2.3 TITANUS PRO·SENS®and interactive technology 26
5.8 Application TITANUS PRO·SENS®and SigmaSys-technology 27
5.8.1 Mounting of the contact coupler SPF 5300 for the extension 28
5.8.2 Electrical connection 29
5.9 Installation of the second detector module 30
5.10 Response indicator - electrical connection 32
5.11 Data Log 33
6Installation Pipe System 6 – 1
6.1 Linear expansion of the pipe system 4
6.2 Patented air sampling points 6
6.3 Ceiling leadthrough 8
6.4 Monitoring in forced air flow systems
(ventilation or climatic applications) 10
6.4.1 Detection at air inlets/outlets 10
6.4.2 Detection in bypass systems 10

TITANUS PRO · SENS®Inhalt
PS-Inhalt-a_en_e Data: 04/09
Contents
6.5 Filter 11
6.5.1 Installation of the air Filter type LF-AD-x 11
6.5.2 Mounting of the special filter type SF-400/650 12
6.6 Air return 13
6.7 Noise suppressor 14
6.8. 3-Way ball valve 15
6.9 Steam trap 17
6.10 Detonation prevention device 18
6.11 Test adapter 19
7Commissioning 7 – 1
7.1 Air flow sensor adjustment 2
7.1.1 Adjustment independent of the air pressure 3
7.1.2 Adjustment dependent on the air pressure 4
7.2 Detector module and alarm transmission 6
7.3 Check air flow monitoring 7
7.4 Check fault signal transmission 8
7.5 Operational check of TITANUS PRO·SENS®9
7.5.1 Preparations for operational check 9
7.5.2 Operational check 10
8Maintenance 8 – 1
8.1 Visual Check 1
8.2 Flash Code Table 1
8.3 Checking detector module and alarm transmission 2
8.4 Checking the pipe system 2
8.5 Exchange of detector module 3
8.6 Changing the air filter LF-AD -x 4
8.7 Changing special air filter SF-400/650 5
8.8 Check of the air flow sensor adjustment 6
8.9 Check air flow monitoring 8
8.10 Check fault signal transmission 8
8.11 Maintenance intervals 8

Contents TITANUS PRO·SENS®
Data: 04/09 PS-Inhalt-a_en_e
Appendix
Air Pressure Adjustment Tables
Projection Tables
System Product List
Certificate of Approval of Components and Systems
EMC Declaration of Conformity
Inspection Protocol
Glossary
Conformity certification pursuant to EU

TITANUS PRO · SENS®Inhalt
PS-Inhalt-a_en_e Data: 04/09

TITANUS PRO·SENS®General
PS-00-a_en_e Date: 04/09 0– 1
0 General
0.1 Introduction
This manual is for installers of air sampling smoke detection systems, in
particular for engineers, technicians, and fitters etc. who have technical
knowledge in the field of smoke detection technology but who are possi-
bly working with this device for the first time.
For damage and faults resulting from the non-observance of this manual
WAGNER Group GmbH, called WAGNER in the following, does not as-
sume liability.
This manual refers to the air sampling smoke detection systems
TITANUS PRO·SENS®and TITANUS PRO·SENS®2. These systems
may only be used for early and very early smoke detection. As the smoke
detection systems are from one series, TITANUS PRO·SENS®is de-
scribed here. Specific technical designs of TITANUS PRO·SENS®2 are
described separately.
0.2 Safety Information
D The following symbols identify parts of the text in this manual which re-
quire special attention so that damage can be avoided and so that opera-
tions can run smoothly.
This symbol warns against actions which might cause damage if it is
ignored.
This symbol warns against actions which could cause operational break-
downs if it is ignored.
Operational improvements can be achieved if this symbol is observed.
ATTENTION
INSTRUCTION
TIP

General TITANUS PRO·SENS®
0– 2 Date: 04/09 PS-00-a_en_e
0.3 Guarantee
The manual is subject to technical modification without notice and makes
no claim to completeness.
In principle our “Terms and Conditions of Supply and Assembly” apply.
No claims under the guarantee or for liability can be made for damage to
persons or property if they are based on one or more of the following
causes:
•insufficient observance of the instructions about the design, assem-
bly of the aspirating smoke detection system, assembly of the pipe
system, commissioning and maintenance
•use of the aspirating smoke detection system in contravention of the
intended use
•insufficient monitoring of working parts
•improperly executed repairs
•unauthorised constructional changes to the aspirating smoke detec-
tion system
•force majeure
0.4 Copyright
The copyright in this Technical Manual remains with WAGNER.
The manual is designed exclusively for the assembler and his col-
leagues.
Reproduction of the manual, including extracts, is not allowed. Copying
or distribution of the manual in any form is only allowed with permission
in writing from WAGNER.

TITANUS PRO·SENS®General
PS-00-a_en_e Date: 04/09 0– 3
0.5 Packaging
The individual air sampling smoke detection systems are packed in ac-
cordance with the anticipated transport conditions. Exclusively environ-
mentally friendly materials were used for the packaging.
The packaging is intended to protect the air sampling smoke detection
system from being damaged until it is installed. For that reason, it should
only be removed from its packaging shortly before installation.
The packaging material is to be disposed of in accordance with applica-
ble statutory provisions and local regulations.
zDispose of the packaging materials in an environmentally friendly
manner.
zObserve local disposal regulations.
Packaging materials are valuable raw materials and in many cases can
be re-used or expediently processed and recycled. Improper disposal of
packaging materials can harm the environment.
0.6 Disposal
If no take-back or disposal agreements have been made, disassembled
components are to be taken for recycling:
zTake metal parts for scrapping.
zTake plastic parts to be recycled.
zSort the remaining components by material quality and dispose of
them.
INSTRUCTION

General TITANUS PRO·SENS®
0– 4 Date: 04/09 PS-00-a_en_e

TITANUS PRO·SENS®Product Description
PS-01-a_en_e Date: 04/09 1– 1
1 Product Description
1.1 Features of the TITANUS PRO·SENS® air
sampling smoke detection system
TITANUS PRO·SENS® is the latest generation of WAGNER air sampling
smoke detection systems. Besides its use for room and equipment pro-
tection the variant can be used for monitoring climatic cabinets and cli-
matic ducts.
Sensitivity The device has a response sensitivity of up to 0.5 %/m, 0.1 %/m or
0.015 %/m light obscuration. According to the application further sensitivi-
ties can be set. Thanks to the innovative High-Power-Light-Source tech-
nology a wide detection range over all rated fire types is guaranteed.
If 2 detector modules are inserted in the TITANUS PRO·SENS®, is the
double of the monitoring area reachable.
LOGIC·SENS In order to prevent false alarms, the intelligent signal processing called
LOGIC·SENS distinguishes between interferences and the occurrence of
real fire.
Safe air flow monitoring Like point-type detectors, which are electronically monitored to detect line
fractures and short circuits, air sampling systems require a complex and
safe air flow monitoring. The unique air flow sensor technology used in all
WAGNER air sampling smoke detection systems guarantees the detec-
tion of faults such as pipe fracture or blockage of air sampling points.
The air flow monitoring is temperature compensated and can be inde-
pendent of the air pressure.
Patented air sampling
points Depending on the required pipe design the air sampling points have de-
fined hole diameters. For these exact airs sampling points WAGNER has
developed patented aspiration-reducing film sheets with marking tape
and clips that permit an easy mounting and avoid secondary noise. An-
other advantage is the quick and easy retrieval and check of the air sam-
pling point diameters.
Point detector spacing The air sampling points of the system can be compared to point-type
detectors. The monitoring areas comply with the valid national regula-
tions.

Product Description TITANUS PRO·SENS®
1– 2 Date: 04/09 PS-01-a_en_e
Diagnostics software The diagnostic software permits a quick and reliable fault localization for
maintenance and service. The current and memorized device state can
be read out to a PC via a special cable.
Choice of ventilator
voltage The fan voltage can be set according to project planning by re-plugging
the plug-in jumpers.
With TITANUS PRO·SENS® devices, the fan voltage can be set between
6.9 V and 9 V by means of the plug-in jumpers on the base board.
The voltage with TITANUS PRO·SENS®devices can be set by means of
the fan control circuit boards FC-2 and FC-3.
•The voltage can be set to 6.5 V, 6.9 V and 9 V with the FC-2 fan
control circuit board. The FC-2 fan control circuit board is stan-
dard in all TITANUS PRO·SENS® -SL devices.
•The voltage can be set to 10 V, 11 V and 12 V with the FC-3 fan
control circuit board. The FC-3 fan control circuit board available
as an option for all TITANUS PRO·SENS®-SL devices.

TITANUS PRO·SENS®Product Description
PS-01-a_en_e Date: 04/09 1– 3
1.2 Areas of Application
The air sampling smoke detection system TITANUS PRO·SENS®is a
smoke detection system used for the early smoke detection and very
early smoke detection in rooms and equipments.
Principle Air samples are drawn from the monitoring area via a pipe system with
defined air sampling points and passed to the detector module.
It is particularly suitable for areas in which point-type detectors cannot be
used or can only be used under certain conditions.
This applies in particular to areas: …
zwith difficult access and in which it is difficult to install or to maintain
point-type detectors.
zwhich are air-conditioned.
zwhich are higher than allowed for point-type detectors.
zin which point-type detectors are not desired for aesthetic reasons.
zin which electromagnetic fields have an impact .
zwhich are exposed to high or low temperature.
zwith pollution of the air, where filter elements are needed.
zwhich are jeopardized by vandalism.
TITANUS PRO·SENS®is suitable for the monitoring of e.g.:
Room protection Rooms like f. e.:
zfloor voids, ceiling voids
ztunnels, ducts, voids difficult to access
zstorage areas, high-rack storage areas, elevator shafts
zmuseums, cultural centre
zdeep-freeze storage areas
TITANUS
PRO·SENS2®
1
2
TITANUS
PRO·SENS2®
1
2
Fig. 1.1: Scheme - room monitoring with the air sampling smoke detection system
TITANUS PRO ·SENS®

Product Description TITANUS PRO·SENS®
1– 4 Date: 04/09 PS-01-a_en_e
Room monitoring
with air conditioning Room monitoring takes place
zin rooms with air conditioning for server rooms, etc.,
zin ventilation ducts,
zvia floor voids, ceiling voids,
zin EDP rooms, distribution cabinets, transformer cells,
zat climatic cabinets (see Fig. 1.2) or
zat climatic ducts in the by-pass.
Fig. 1.2: Monitoring possibilities of a convection air conditioning system or climatic duct
(scheme)

TITANUS PRO·SENS®Product Description
PS-01-a_en_e Date: 04/09 1– 5
Equipment Protection non-ventilated and ventilated installations/cabinets like f. e.
zdistribution cabinets, switch cabinets
ztelephone switch boards
zmeasuring and control units
Fig. 1.3: Scheme - equipment monitoring with the air sampling smoke detection system
TITANUS PRO·SENS®
The air sampling system TITANUS PRO·SENS®can also be used for ear-
liest fire detection in rooms with special air conditioning.
Valuable goods and installations can be reliably monitored due to the system’s
high sensitivity. Therefore, TITANUS PRO·SENS® is especially suited for
the following areas:
zwhere early intervention is crucial due to valuable assets
zwhere systems must be operational at all times
zwhere highly sensitive detection is required (e.g. in areas where filters
keep smoke particles in the air at a minimum)
zwith high air exchange rates

Product Description TITANUS PRO·SENS®
1– 6 Date: 04/09 PS-01-a_en_e
Other manuals for TITANUS PRO-SENS
1
Table of contents
Other WAGNER Security Sensor manuals
Popular Security Sensor manuals by other brands

Theben
Theben thePassa P360-101 UP WH manual

iRay Technology
iRay Technology Mars1717X user manual

IFM Electronic
IFM Electronic efector300 SM8001 operating instructions

Niko
Niko 25421 quick start guide

Simplex
Simplex 2098-9201 Cleaning instructions

Tractel
Tractel Stopcable EN 353-1 Operating and maintenance instructions

Varian
Varian 959D Operation manual

Honeywell
Honeywell ADEMCO 5808EU installation instructions

Code 3
Code 3 Z3 Series Installation & operation manual

PCB
PCB 2303-02A Installation and operating manual

Larson Electronics
Larson Electronics EXP-MS-N4X-AT-HV instruction manual

Ametek
Ametek Ortec radEAGLET-R Series user manual