Congratulations on your purchase of this high-quality ESYLUX product. To ensure proper operation, please read
these user instructions carefully and keep them for future reference.
1 • SAFETY INSTRUCTIONS
CAUTION: Work on the 230 V power system must be carried out by authorised personnel only
with due regard to the applicable installation regulations. Switch off the power supply before
installing the system.
Use this product only as intended (as described in the user instructions). Changes or
modifications to the product or painting it will result in loss of warranty. You should check
the device for damage immediately after unpacking it. If there is any damage, you should
not install the device under any circumstances. If you suspect that safe operation of the
device cannot be guaranteed, you should turn the device off immediately and make sure
that it cannot be operated unintentionally.
2 • DESCRIPTION
ESYLUX RCi series motion detectors have a 130°/230°/280° field of detection and 360°
creep zone protection. ESYLUX motion detectors are passive infrared detectors that react to
moving heat sources (people, vehicles) (fig. 1 (1) 360° creep zone protection (2) Facing detector
(3) Diagonal to detector). If the motion detector registers changes in the heat emissions within
its field of detection, depending on the set Lux level, it switches on the connected load
(e.g. lighting) for an adjustable length of time. The ESYLUX RCi motion detector series can
be mounted onto a wall or ceiling without the need for any further accessories.
A base is available to allow it to be mounted to an internal or external corner.
The ESYLUX RCi motion detector has a default programme allowing it to work within
predefined parameters (10 Lux, 2 minutes, max. electronic range). There are two different
ways of setting the detector – either conventionally using the setting controls on the device
itself, or using the convenient optional remote control, ESYLUX Mobil-RCi or Mobil-RCi-M.
NB: To activate all functions on the detector,
the remote control Mobil-RCi is required.
3 • INSTALLATION/MOUNTING/CONNECTION
Please observe the following points prior to fitting the device:
• The power supply must be disconnected prior to fitting.
• All data concerning the range presume an installation height of 2.50 m.
(If installed at a different height the values for the range will be affected).
• Best results (max. range) are achieved if the device is installed diagonally to the direction
of motion (fig. 1).
• Ensure that there are no obstacles between the area to be covered and the detector, as
infrared rays cannot penetrate solid matter.
• To ensure that the built-in light sensor is not affected, ensure that there is a minimum of
1 m between the motion detector and the connected lighting, and that light sources are
not focused directly on the detector.
• Please consider the environment in which the device is to be fitted, such as any
neighbouring gardens and the distance to the street.
• The motion detector should only be mounted on a solid, even base (wall/ceiling).
The wall base and the sensor can be plugged into one another. To install, disconnect both
parts. Insert a screwdriver into the side opening and lever off towards the sensor, pulling the
wall connection base away from the sensor (fig. 2.1). If mounting on a wall, the cable entry
points must face downwards. If mounting on ceiling, they must face the front. Insert the
cable and mount the wall base in the desired position (fig. 3). Connect the motion sensor as
directed in the circuit diagram (fig. 4).
CAUTION: The maximum inrush current must not be exceeded when connecting to capacitive loads
such as electronic ballasts or fluorescent lamps with parallel compensation.
(4.1) Standard operating mode
(4.2) Parallel switching of max. 8 devices
(4.3) If switching inductance (e.g. relays, contactors, series connection units) the use of a
quenching circuit (A) may be required
(4.4) Standard operating mode with the added option of constant lighting mode using an
external switch
(4.5) Parallel switching and stairway lighting machine
(4.6) Standard operating mode with the added option of manual switching.
If fitting to a ceiling, the two sensor parts are turned away from each other by 180° (fig. 5).
Fit the detector onto the wall base and press to slot into position (fig. 2.2).
NB: The motion detector must always be fitted
so that the sensor faces down.
4 • STARTING UP AND SETTING
Once the device has been successfully installed and the power supply has been switched
back on, the device carries out an auto-test cycle lasting approx. 60 seconds. This is
indicated by the focus LED flashing and the connected loads being activated. Once this
phase is complete, the device is ready to use. The settings are concealed within the casing.
By pressing up and then letting go of the lens, the detector head is unlocked and protrudes
from the casing by approx. 1 cm. Repeat this procedure to allow the sensor head to return
to its original, locked position (fig. 6, works like a retractable ball-point pen). A range of
further setting options/special functions are available with the optional remote control Mobil-
RCi.
4.1 Test mode
Set the operating mode option button (fig. 7.1) to “Test”.
NB: Test mode can also be activated using the remote control Mobil RCi
(see section 6).
During test mode the focus LED is permanently switched on. Each time motion is detected,
regardless of the light exposure level, the detector switches the load ON for 1 second and
OFF for 2 seconds. The following options allow you to adjust the field of detection to suit the
environment in which the device is installed:
• Turning the sensor head horizontally by +/- 90° (unlock sensor head first, see fig. 6).
The central position is indicated by the red arrow.
• Control the range for each sensor field by mechanically raising each individual sensor.
(fig. 7.2). The position is displayed optically by the focus LED (fig. 8). The RC 130i has
1 sensor, the RC 230i has 2 and the RC 280i has 3.
• Use of the supplied covering cap for masking specific areas (fig. 9).
Once the field of detection is set, turn the operating switch to “ ”, to make the
adjustments using the settings on the device, or to “ ”, to run the default
programme or to make other settings using the remote control.
5 • OPERATING/PROGRAMMING
Every time movement is detected the focus LED lights up for 2 seconds. This function can be
switched off (see section 6). The motion detector switches the load on for the set length of
time, depending on the set light exposure level.
Setting unit operating mode button (fig. 7.1).
NB: The operating mode button allows you to set the parameters for the device. You can either
simply select the values using the settings (fig.s 7.3 and 7.4) on the device or use the default
programme, or the set parameters using the remote control. You can switch the settings at any
time; the defined values apply.
Test mode: See section Test Mode
Manual mode : Device operates according to the parameters on the settings
(fig. 7.3 and 7.4).
Auto/RC Modus : Devices operates according to the default programme or
the parameters defined using the remote control.
Default programme
Set the operating button (fig. 7.1) to “ ”. If no values have yet been defined with
the remote control, the detector operates according to the default programme. This consists
of two fixed values for the length of time the device is switched on, the electronic setting for
the field of detection and the light exposure level (2 minutes/maximum electronic range/
10 lux). These values can be individually adjusted using the remote control. To return
settings to the original default values, press the button (ensure that you are in
programming mode) on the remote control Mobil-RCi.
Activation time setting button (fig. 7.3)
Activation time adjustable: impulse, 15 seconds – 16 minutes. Impulse means that the device
is activated for approx. 1 second followed by a break of approx. 9 seconds in which no
movement is detected. The focus LED is activated for 2 seconds for each sequence. After the
break time a new sequence is triggered if motion is detected. This is suitable, for example,
to activate a gong.
Light exposure level setting button (fig. 7.4)
The light exposure level is infinitely variable between 2 – 2500 Lux.
Range control setting button (fig. 7.2)
Depending on the model there are 1 to 3 setting buttons. The control unit for setting the
range depends on the settings on the operating mode button.
Range control: from approx. 20 m – approx. 5 m.
• •RC 130i
• •RC 230i
• •RC 280i
MOTION DETECTORS
www.esylux.com
MOTION DETECTORS
GB
FIG. 1
FIG. 2 FIG. 3 FIG. 4
FIG. 5 FIG. 6 FIG. 7
FIG. 8 FIG. 9 FIG. 10
Tes t
RC
Auto
LUX
12sec.
16min.
LUX
12min 16min
8min
RESET TEST
PULSE
30min
4min
15 sec 30sec 1min 2min
ON/OFF
12h
ON/OFF
S
ON/OFF
360
°
RESET
ON/OFF
12h
Tes t
RC
Auto
LUX
12sec.
16min.
LUX
FOCUS-LED
Test
RC
Auto
LUX
12sec.
16 min.
LUX
Test
RC
Auto
LUX
15 sec. 16 min.
LUX
TOP
LNL
Löschglied
Treppenlichtautomat
t
7.1
4.1 4.2 4.3
4.4 4.5 4.6
2.1
2.2
7.2 7.3 7.4
6 • REMOTE CONTROL
NB: To use the remote control Mobil-RCi, the operating mode button must be set to
“ ” (fig. 7.1). If the operating button is set to “ ” and if no
parameters have yet been entered via the remote control, the device operates using a preset
default programme (10 Lux/2 minutes/max. electronic range).
All entries made by remote control are saved permanently. If there is a power cut, the
settings are restored. The settings can conveniently be made from the ground without the
need for a ladder or tools using the Mobil-RCi or Mobil- RCi-M (fig. 10) remote control.
For best results, point the remote control at the motion detector when programming the
device. Please note that if exposed to direct sunlight, the standard range of approx. 6 m
is considerably reduced on account of the infrared emissions from the sun.
6.1 Confirmation of commands on the device:
Command understood and carried out.
Focus-LED 2 seconds ON, the relay switches on twice for 1 second.
Command not understood.
Focus-LED flashes twice, the relay is not responding.
6.2 Standard functions/programming mode
There are basically two difference options for entering values via the remote control.
Standard functions
These functions can be selected directly:
• Test mode
• Continuous light mode ON/OFF
• Reading the current light exposure level
• Reset (reset the current modes)
• Master X
• Programming mode
Programming mode
These functions can only be selected/set if the device
is in programming mode button .
• Predefined light levels
• Predefined activation time
• Activating the impulse mode
• Holiday mode
• Alarm mode
• Creep zone protection ON/OFF
• Focus-LED ON/OFF
• Electronic range control
• Reset – (reset to default programme/factory settings)
NB: The special features impulse, vacation and alarm mode cannot be used at the same time.
The programme activated most recently is active.
RC
Auto
RC
Auto
RESET
Mobil-RCi-M Mobil-RCi
RC
Auto
RC
Auto
RC
Auto
1
2
3
2,50 m
3 m
6 m
20 m
36 m
130°
2,50 m
3 m
6 m
20 m
40 m
230°230°
2,50 m
3 m
6 m
20 m
40 m
6 m
3 m
20 m
280°
Button Function
Opens programming mode
Display by flashing Focus LED.
The set values are active once the programming mode is
closed, or are automatically activated after 5 minutes.
Test mode
During test mode the focus LED is switched on permanently.
Each time movement is detected, regardless of how the light exposure
level, the detector switches ON for 1 second and OFF for 2 seconds. Press
the button to quit test mode.
Recording the current light exposure level
Records the current light exposure level.
TEST
Setting the light source (programming mode)
Day and night operating mode
The sun is starting to set (approx. 100 Lux)
The sun is almost set (approx. 25 Lux)
Night mode (approx. 2 Lux)
ON/OFF
360
°
Impulse mode (programming mode)
Impulse means that the device is activated for 1 second followed by a
break of 9 seconds in which no movement is detected. The focus LED is
activated for 2 seconds for each sequence. After the break time a new
sequence is triggered if motion is detected. This is suitable, for example,
to activate a gong.
PULSE
Continuous light mode ON/OFF
Load is switched ON/OFF for max. 12 hours, regardless of the light
exposure level or movements.
NB: The function continuous light mode OFF is deactivated by the manufacturer
so that the device cannot be tampered with. It can only be activated during an
auto-test cycle. To run this, connect the power supply and press the
button. The function continuous light mode OFF is now activated.
To deactivate this function press the button when the device is in
programming mode (reset to default setting).
Operating continuous light mode ON/OFF
Continuous light mode OFF deactivated – Every time the button is
pressed, the light switches ON for 12 hours.
Continuous light mode OFF activated – Pressing the button once
switches the light ON for 12 hours. If the button is pressed again, the
light is switched OFF for 12 hours. Pressing the button a further time
switches the light ON – OFF – ON in sequence.
NB: Pressing the button deactivates the special function impulse mode,
alarm mode and holiday mode. Once the 12 hours have expired, or the
continuous light mode is cancelled by pressing the button, the detector
switches to automatic mode.
ON/OFF
12h
Switching time (programming mode)
Adjustable from 15 seconds to 30 minutes.
15 sec
30min
RESET
ON/OFF
12h
ON/OFF
12h
ON/OFF
12h
ON/OFF
12h
Closes programming mode TECHNICAL DATA
MAINS VOLTAGE
FIELD OF DETECTION
230 V ~ 50 Hz
130° (1 x 130° can be set independently)
and 360°creep zone protection
230° (2 x 115° can be set independently)
and 360°creep zone protection
280° (3 x 95° can be set independently)
and 360°creep zone protection
RANGE approx. 20 m, at an installation height of 2.50 m
SETTINGS Mechanically using the setting controls,
electronically using the infrared remote control
TIME SETTING Impulse/approx. 15 seconds - 30 minutes
SWITCHING CAPACITY 230 V ~ 50 Hz,
2300 W/10 A (cos ϕ= 1),
1150 VA/5 A (cos ϕ= 0,5)
LIGHT EXPOSURE VALUE
APPROX. 2 - 2500 Lux
PROTECTION TYPE/CLASS IP 54, II
TEST SYMBOL TÜV Süd
OPERATING TEMPERATURE
RANGE -25 °C…+55 °C
CASING UV-stabilised polycarbonate
COLOUR white, similar to RAL 9010,
brown, similar to RAL 8017,
black, similar to RAL 9005,
Stainless steel look
APPROX. DIMENSION Width 78 mm,
Height 105 mm,
Depth 135 mm
360° creep zone protection ON/OFF (programming mode)
Deactivate the 360° sensor, which should be facing down, to avoid the
device switching on accidentally. Press the button again to reactivate
creep zone protection.
ON/OFF
Focus LED ON/OFF (programming mode)
Press this button once to switch off the Focus LED – press again
to switch it back on. The Focus LED briefly lights up to indicate that it is
active. It continues to confirm that a function has been activated.
Alarm mode (programming mode)
If movement is detected the detector switches ON for 1 second and OFF
for 1 seconds. This continues for 30 seconds (flashing phase). Then the
light switches to continuous mode for the rest of the activation time, or
another alarm phase is triggered if motion is detected. To cancel this
function, press the button. To end the alarm function, press the
button.
Holiday mode (programming mode)
This function activates the connected lighting for 4 hours once a
predefined light level is reached, regardless of whether motion is
detected or not. Once the 4 hours have expired, the motion detector
switches back to automatic mode. The process is repeated every day.
To cancel, press the button.
To quit holiday mode, press the button.
RESET
Reset
Rest to automatic mode. This cancels alarm mode, holiday mode, test
mode and night activation time.
Reset – in programming mode
Reset to default settings. Deletes all values set by the remote control and
resets all functions. The device operates according to its predefined
default programme (10 Lux/2 minutes/max. electronic range).
NB: If the continuous light mode OFF function is to be used,
this will need to be reactivated.
Master X
This is used to activate the continuous light OFF function (see continuous
light ON / OFF) and to cancel the night activation times.
S
Electronic range control
This function electronically increases or decreases the range by +15 %
and - 30 % respectively.
The button resets the default settings.
ON/OFF
360
°
RESET
RESET
S
7 • PRACTICAL ADVICE
• The device can be activated by small animals or branches and bushes swaying in
the wind.
• The range can be greatly decreased if the person/vehicle approaches the detector
head on.
Technical and design features may be subject to change.
ON/OFF
12h
ESYLUX GmbH
Postfach 1834, 22908 Ahrensburg/Germany
Internet: www.esylux.com
e-mail: [email protected]
WA 12/2008
MAX INRUSH CURRENT 100A/250µs
100A/250µs
100A/250µs
RESET

Other manuals for RC 130i

1

This manual suits for next models

2

Other ESYLUX Security Sensor manuals

ESYLUX MD 120 User manual

ESYLUX

ESYLUX MD 120 User manual

ESYLUX MD-W200i User manual

ESYLUX

ESYLUX MD-W200i User manual

ESYLUX PD 360/8 Basic Operating and maintenance manual

ESYLUX

ESYLUX PD 360/8 Basic Operating and maintenance manual

ESYLUX PD 360/8 KNX BASIC User manual

ESYLUX

ESYLUX PD 360/8 KNX BASIC User manual

ESYLUX RC 230i KNX User manual

ESYLUX

ESYLUX RC 230i KNX User manual

ESYLUX EP10427404 User manual

ESYLUX

ESYLUX EP10427404 User manual

ESYLUX MD 180i/16 BASIC CH User manual

ESYLUX

ESYLUX MD 180i/16 BASIC CH User manual

ESYLUX SMB MD 360i/24 Basic SMB Operating and maintenance manual

ESYLUX

ESYLUX SMB MD 360i/24 Basic SMB Operating and maintenance manual

ESYLUX MD-C360i/6 mini User manual

ESYLUX

ESYLUX MD-C360i/6 mini User manual

ESYLUX PD-C360i/24 KNX ECO User manual

ESYLUX

ESYLUX PD-C360i/24 KNX ECO User manual

ESYLUX PD-C360i/24 KNX UP User manual

ESYLUX

ESYLUX PD-C360i/24 KNX UP User manual

ESYLUX PD-FLAT 360i/6 mini DALI User manual

ESYLUX

ESYLUX PD-FLAT 360i/6 mini DALI User manual

ESYLUX RC 130i User manual

ESYLUX

ESYLUX RC 130i User manual

ESYLUX DEFENSOR MD 200 24 IR 1C IP55 WH User manual

ESYLUX

ESYLUX DEFENSOR MD 200 24 IR 1C IP55 WH User manual

ESYLUX PD-C360i/24 DUOplus-FM User manual

ESYLUX

ESYLUX PD-C360i/24 DUOplus-FM User manual

ESYLUX PROTECTOR KRF TCV 2G User guide

ESYLUX

ESYLUX PROTECTOR KRF TCV 2G User guide

ESYLUX MD-C360i/8 Series User manual

ESYLUX

ESYLUX MD-C360i/8 Series User manual

ESYLUX EP10425806 User manual

ESYLUX

ESYLUX EP10425806 User manual

ESYLUX PD-C360i/8 DUO DALI User manual

ESYLUX

ESYLUX PD-C360i/8 DUO DALI User manual

ESYLUX PROTECTOR WD 9 V User manual

ESYLUX

ESYLUX PROTECTOR WD 9 V User manual

ESYLUX PD-C360i/24 DIMplus User manual

ESYLUX

ESYLUX PD-C360i/24 DIMplus User manual

ESYLUX MD-C360i/6 mini User manual

ESYLUX

ESYLUX MD-C360i/6 mini User manual

ESYLUX PD-C360i/24 DIMplus-FM User manual

ESYLUX

ESYLUX PD-C360i/24 DIMplus-FM User manual

ESYLUX EP10426155 User manual

ESYLUX

ESYLUX EP10426155 User manual

Popular Security Sensor manuals by other brands

Omron E4A-3K manual

Omron

Omron E4A-3K manual

Edax Element user guide

Edax

Edax Element user guide

Diablo Controls DSP-15 user manual

Diablo Controls

Diablo Controls DSP-15 user manual

Texecom Premier Elite Impaq Plus-W user manual

Texecom

Texecom Premier Elite Impaq Plus-W user manual

BGB 33333-A instruction manual

BGB

BGB 33333-A instruction manual

Data Harvest 1190 manual

Data Harvest

Data Harvest 1190 manual

Care Call CCM3A-2216-EU-PIR quick start guide

Care Call

Care Call CCM3A-2216-EU-PIR quick start guide

Surface Concept DLD4040 manual

Surface Concept

Surface Concept DLD4040 manual

netvox R718WAA user manual

netvox

netvox R718WAA user manual

Knauer Azura RID 2.1L instructions

Knauer

Knauer Azura RID 2.1L instructions

DOLD Safemaster W UH 6900 user manual

DOLD

DOLD Safemaster W UH 6900 user manual

Bacharach MGD-100 Installation and operation manual

Bacharach

Bacharach MGD-100 Installation and operation manual

Waters 2998 Operator's guide

Waters

Waters 2998 Operator's guide

AJAX MotionProtect user manual

AJAX

AJAX MotionProtect user manual

olympia electronics BSR-6160 quick start guide

olympia electronics

olympia electronics BSR-6160 quick start guide

Radon TEVISO RA14 Application notes

Radon

Radon TEVISO RA14 Application notes

Bosch 0603683000 Original instructions

Bosch

Bosch 0603683000 Original instructions

ISYGLT BW-03 Technical Data/Instruction Manual

ISYGLT

ISYGLT BW-03 Technical Data/Instruction Manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.