4 Table of Contents WAGO-I/O-SYSTEM 750
750-464 2/4 AI RTD configurable
Manual
Version 1.1.0
4.3.2 Pt200 (acc. IEC 751).........................................................................42
4.3.3 Pt500 (acc. IEC 751).........................................................................43
4.3.4 Pt1000 (acc. IEC 751).......................................................................44
4.3.5 Ni100 (acc. DIN 43760).....................................................................45
4.3.6 Ni120 (Minco)....................................................................................46
4.3.7 Ni1000 (acc. DIN 43760)...................................................................47
4.3.8 Ni1000 TK5000 .................................................................................48
4.3.9 Resistance Measurement 10 Ohm … 1.2 kOhm...............................49
4.3.10 Resistance Measurement 10 Ohm … 5.0 kOhm...............................50
4.3.11 Potentiometer....................................................................................51
4.4.1 Process Data of the Standard Version 750-464
(RTD, configurable) Siemens Format................................................52
4.4.2 Pt100 (acc. IEC 751).........................................................................52
4.4.3 Pt200 (acc. IEC 751).........................................................................53
4.4.4 Pt500 (acc. IEC 751).........................................................................54
4.4.5 Pt1000 (acc. IEC 751).......................................................................55
4.4.6 Ni100 (acc. DIN 43760).....................................................................56
4.4.7 Ni120 (Minco)....................................................................................57
4.4.8 Ni1000 (acc. DIN 43760)...................................................................58
4.4.9 Ni1000 TK5000 .................................................................................59
4.4.10 Resistance Measurement 10 Ohm … 1.2 kOhm...............................60
4.4.11 Resistance Measurement 10 Ohm … 5.0 kOhm...............................61
4.4.12 Potentiometer....................................................................................62
4.5 Data of the Version 750-464/020-000 (NTC, configurable) ...................63
4.5.1 NTC 10 kOhm ...................................................................................63
4.5.2 NTC 20 kOhm ...................................................................................64
4.5.3 NTC 10 kOhm Thermokon ................................................................65
4.6 Data of the Version 750-464/020-000 (NTC, configurable) Siemens
Format....................................................................................................66
4.6.1 NTC 10 kOhm ...................................................................................66
4.6.2 NTC 20 kOhm ...................................................................................67
4.6.3 NTC 10 kOhm Thermokon ................................................................68
5Mounting ...................................................................................................69
5.1 Mounting Sequence...............................................................................69
5.2 Inserting and Removing Devices ...........................................................70
5.2.1 Inserting the I/O Module....................................................................70
5.2.2 Removing the I/O Module..................................................................71
6Connect Devices.......................................................................................72
6.1 Connecting a Conductor to the CAGE CLAMP®....................................72
6.2 Connection Examples............................................................................73
6.2.1 750-464 (RTD) Version, 4-Channel Operation..................................73
6.2.1.1 4 x 2-Wire .....................................................................................73
6.2.1.2 Special Features in 4-Channel Operation ....................................73
6.2.1.2.1 Open Input Wiring ....................................................................73
6.2.1.2.2 Measuring Circuit Line Break Detection...................................74
6.2.1.2.3 Influencing a Measuring Circuit Channel through a Quick
Change in Temperature ...........................................................74
6.2.2 750-464 (RTD) Version, 2-Channel Operation..................................74
6.2.2.1 2 x 2-Wire .....................................................................................74