Watts tekmar 088 User manual

The Pressure Sensor 088 provides a ratiometric signal to a
controller to measure the pressure of a hydronic system between
0 to 150 psi (0 to 1034 kPa). The sensor bulb is designed to
install into a tee using 1⁄8"-27 NPT threads and includes a
10 foot (3 m) long cable.
Introduction
IOM-T-088
Installation, Operation and Maintenance
Pressure Sensor 088
WARNING
!
Please read carefully before proceeding with
installation. Your failure to follow any attached
instructions or operating parameters may lead to
the product’s failure.
Keep this Manual for future reference.

2IOM-T-088 2205 © 2022 tekmar
Important Safety Information ................................................................... 3
Installation ................................................................................. 4
Check the Contents ....................................................................... 4
Preparation .............................................................................. 4
Installation Location ....................................................................... 4
Step 1 – Rough In Wiring ................................................................... 4
Step 2 – Mounting ........................................................................ 4
Step 3 – Wiring ........................................................................... 4
Testing and Troubleshooting ................................................................... 5
Technical Data .............................................................................. 7
Limited Warranty and Product Return Procedure .................................................... 8
Table of Contents

3
IOM-T-088 2205 © 2022 tekmar
Important Safety Information
It is your responsibility to ensure that this control is safely installed according to all applicable codes and standards.
Watts®is not responsible for damages resulting from improper installation and/or maintenance.
This is a safety-alert symbol.
The safety alert symbol is shown
alone or used with a signal
word (DANGER, WARNING, or
CAUTION), a pictorial and/or a
safety message to identify hazards.
When you see this symbol alone or
with a signal word on your equip-
ment or in this manual, be alert to
the potential for death or serious
personal injury.
This pictorial alerts you to electricity,
electrocution, and shock hazards.
This symbol identifies hazards which, if not avoided, could
result in death or serious injury.
This symbol identifies hazards which, if not avoided, could
result in minor or moderate injury
This symbol identifies practices, actions, or failure to act
which could result in property damage or damage to
the equipment.
• It is the installer’s responsibility to ensure that this
sensor is safely installed according to all applicable
codes and standards.
• This sensor is not intended for use as a primary
limit device. Other devices that are intended and
certified as safety limits must be placed into the
control circuit.
NOTICE
Read manual and all product labels
BEFORE using the equipment.
Do not use unless you know the
safe and proper operation of this
equipment. Keep this manual
available for easy access by all
users. Replacement manuals are
available at tekmarControls.com
Do not attempt to service the sensor. There are no
user serviceable parts inside the sensor. Attempting to
service the sensor voids the warranty.

4IOM-T-088 2205 © 2022 tekmar
• One pressure sensor bulb
• One 10 foot electrical cable with connector
• One Installation and Operation Manual IOM-T-088
Check the Contents
Installation
• 22 mm or Crescent wrench • Flathead screwdriver
Tools Required
Materials Required
• Pipe joint compound or PTFE tape
Preparation
Check the contents of this package. If any of the contents listed are missing or damaged, please refer to the Limited
Warranty and Product Return Procedure on the back of this brochure and contact your wholesaler or tekmar®sales
representative for assistance. Type 088 includes:
• A tee with 1⁄8"-27 NPT threads should be located on a
pipe near the hydronic system’s expansion tank.
• Keep dry. Avoid potential leakage onto the sensor.
Installation LocationInstallation Location
• The sensor cable is 10 feet (3 m) in length. This can be
extended up to 100 feet (30 m) using 3-conductor 18
AWG solid or stranded cable. The cable is color coded
with black, red and green wire jackets.
• Strip wire to 3⁄8" (10 mm) for all terminal connections.
Installation LocationStep 1 – Rough In Wiring
• Apply pipe joint compound or PTFE tape to the sensor
threads.
• Thread sensor into the tee. Tighten with wrench.
• Connect the cable to the sensor using the Metri-Pack
electrical connector.
• Should the cable need to be disconnected from the
sensor bulb, use a flathead screwdriver to release the
electrical connector spring-loaded clip.
Installation LocationStep 2 - Mounting
• Pull wires through a conduit as required by electrical
codes.
Installation LocationStep 3 - Wiring
Conduit Connector
• Terminate the black conductor to the control’s power
common.
• Terminate the red conductor to the control’s 5 V(dc)
reference voltage.
• Terminate the green conductor to the control’s ratiometric
signal input.
Terminating

5
IOM-T-088 2205 © 2022 tekmar
Testing and Troubleshooting
An electrical multimeter capable of measuring between 0 to 5 volts DC is required.
Using the electrical meter probes, measure the voltage between the black (power common) and red (reference voltage)
wires. The expected voltage is 5.0 V(dc).
Using the electrical meter probes, measure the voltage between the black (power common) and green (ratiometric
signal input) wires. The voltage signal should be between 0.5 to 4.5 V(dc). Using the lookup table below, compare the
measured voltage to a mechanical pressure gauge mounted on the hydronic system. The signal should be accurate
within 1% over the full scale.
Pressure (psi) Pressure (kPa) Ratiometric Voltage (Vdc)
0 0 0.50
534 0.63
10 69 0.77
15 103 0.90
20 138 1.03
25 172 1.17
30 207 1.30
40 276 1.57
50 345 1.83
60 413 2.10
70 482 2.37
80 551 2.63
90 620 2.90
100 689 3.17
110 758 3.43
120 827 3.70
130 896 3.97
140 965 4.23
150 1034 4.50
Pressure vs Voltage Table

6IOM-T-088 2205 © 2022 tekmar
Notes
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________________

7
IOM-T-088 2205 © 2022 tekmar
Technical Data
Pressure Sensor 088
Literature Submittal, Installation and Operating Manual
Maximum Operating Pressure 0 to 150 psi (0 to 1034 kPa)
Operating Temperature Range -40 to 257°F (-40 to 125°C)
Burst Pressure 450 psi
Acceptable Fluid Media Water, glycol solution, steam
Dimensions 0.87" ø x 2.3" L (22.0 mm ø x 58.5 mm L), cable: 10 feet (3.0 m)
Threads 1/8-27 NPT
Sensor 5 V(dc) ratiometric signal, +/-1% accuracy
Materials 304 stainless steel (sensor bulb); 3-conductor, 24 AWG with PVC cable jacket
Packaged Weight 0.40 lb. (180 g)

Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product
(“Product”), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it
has read and understands same.
The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-through warranty which
the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against
defects in workmanship and materials if the Product is installed and used in compliance with tekmar’s instructions, ordinary wear
and tear excepted. The pass-through warranty period is for a period of twenty-four (24) months from the production date if the Prod-
uct is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four
(24) months from the production date.
The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts and labor provided by
tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a
warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange
or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in
contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, spe-
cial, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials,
including any liability for fundamental breach of contract.
The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Lim-
ited Warranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or
replacement Product, all such costs and expenses being subject to Purchaser’s agreement and warranty with its customers.
Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the
tekmar Limited Warranty are the Purchaser’s sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless
from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such repre-
sentations or warranties by Purchaser to its customers.
The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than
tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made sub-
sequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar’s
instructions and / or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in
compliance with tekmar’s instructions.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO
CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE, DURABILITY OR DESCRIPTION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS
OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY
LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL
NOT EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS
ALLOWED BY THE GOVERNING LAW.
Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materials must be returned,
together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located.
If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar
Representative) or Purchaser’s customers, regarding a potential warranty claim, tekmar’s sole obligation shall be to provide the address
and other contact information regarding the appropriate Representative.
IO M -T- 088 2205 © 2022 tekmar
Tel: 1-800-438-3903 • Fax: (250) 984-0815
tekmarControls.com
All specifications are subject to change without notice
Limited Warranty and Product Return Procedure
Table of contents
Other Watts Accessories manuals

Watts
Watts Dormont 2650NPVF36 User manual

Watts
Watts BMS User manual

Watts
Watts PM-070 Manual

Watts
Watts tekmar 087 User manual

Watts
Watts SunTouch ConnectPlus User manual

Watts
Watts Wireless Pressure Sensor User manual

Watts
Watts Snow/Ice Sensor Socket 091 User manual

Watts
Watts Tekmar 077 User manual

Watts
Watts Climatic Control CC-H User manual
Popular Accessories manuals by other brands

Eachine
Eachine EV300O user manual

Microtek
Microtek ADF-600EL Installation and operation manual

Advance acoustic
Advance acoustic BiPro3 manual

Pepperl+Fuchs
Pepperl+Fuchs PXV100A Series Configuration instructions

VOLTCRAFT
VOLTCRAFT PB-14 operating instructions

ADT
ADT Pulse Interactive Solutions DBC845 installation guide