2 
 
To set the custom temperatures, simply power up the thermostat to be added to the 
network and set the modes at the desired temperatures. This must be done before adding 
the thermostat to the Room Key Controller. The Room Key Controller will grab the 
temperature set points from the thermostat when it is added to the network. Multiple 
thermostats are supported but only the temperatures from the first thermostat will be 
recorded. The Room Key Controller will always set all thermostats in the room to the 
same temperature. 
 
This mode of operation is particularly useful when hotel guests manually change the 
thermostat temperature. Once the card is inserted or removed, all thresholds will go back 
to the originally programmed setting. 
 
Custom Set Points Re-Programming 
 
To set new custom set points for the Room Key Controller follow the following 
procedure: 
 1. Power down all thermostats in the room. 
2. Insert the key card in the slot. Wait 15 seconds. 
3. Remove key card from the slot. Wait 15 seconds. 
4. Power up all thermostats in the room and set all of the thresholds manually in the 
thermostats. 
5. Insert the key card in the slot. –Room Key Controller will grab the new thresholds 
and program them into non volatile memory. 
 
Stand Alone \ Indicator Mode 
The Room Key Controller can be configured to act in Stand Alone mode (factory default) 
where all control functions for the room are controlled by the Room Key Controller or in 
Indicator mode where the Controller switches from Room Controller to Key 
insertion\removal sensor. In this mode, the Room Key Controller sends key status 
information to another controller such as Hotel Manager AG. When the Room Key 
Controller is reset, it will automatically go to Stand Alone mode. Indicator mode can be 
set via the parameter command which is only accessible with a compatible Controller. 
 
 
 
PARAMETER # 
PARAMETER 
NAME DEFAULT
DESCRIPTION 
VALID 
VALUES 
1 Stand Alone 1 Sets Stand Alone mode (1) 
or Indicator mode (0) 
0-1