WEIGL ProCommander LX Quick start guide

Version 1.05
RS232-1via Adapter-Cable
CAT 5 cable
CAT 5 cable
Daisy-Chain Connection for Pro-I/O
NETWORK
USB for Control and Configuration
Volume +
Volume -
Press button to store permanently
changes in menu
Device address 1
(!ssi1#)
Device address 2
(!ssi2#)
Device address 3
(!ssi3#)
FRONT WIRING DIAGRAM FOR ProCommander LX
Weigl-EM | +43 650 84 333 48 | www.Weigl-EM.at | Office@Weigl-EM.at
Weigl-EM is t he h eadq uar ter an d ha rdw are ma nufa ctur er
Weigl Works, LLC | +1 440 941 5849 | www.WeiglWorks.com | Info@WeiglWorks.com
Weigl Wo rks, LLC is t he e xclusive No rt h Am erica n d ist rib uto r o f Weig l-EM p rod uct s
©2014 - Weigl-EM & Weigl Works, LLC – Information deemed accurate, but not guaranteed. Subject to change without notice. Images used with consent and remain the property of the c opyright holder.
RS232-1/NET-IN
1: RS485-2 +
2: RS485-2 –
3: RS232-1 RXD
4: RS485-1 + (WEM-NET)
5: RS485-1 – (WEM-NET)
6: RS232-1 TXD
7: PS+ (DC24V/max. 50mA)
8: GND
RS232-2/NET-OUT
1: RS485-2 +
2: RS485-2 –
3: RS232-2 TXD
4: RS485-1 + (WEM-NET)
5: RS485-1 – (WEM-NET)
6: RS232-2 RXD
7: PS+ (DC24V/max. 50mA)
8: GND
RS232-1 shares RS485-1
RS232-2 shares RS452-2
1
1
8
8
Rel1
1N4007
D1
1
1
2
2
3
4
RELAY 9
Rel1
1N4007
D1
1
1
2
2
3
4
RELAY 8
Rel1
1N4007
D1
1
1
2
2
3
4
RELAY 1
IN 9-IN 16
100NF/50V
C1
10K
R2
10K
R1
D1
ZP D5V1
2
11
1
1
2
2
2
TO _AD-CONVERTER
INPUT CIRCUIT IN9-IN16
IN 1-IN 8
100NF/50V
C1
10K
R2 10K
R1
D1
ZP D5V1
2
1
1
1
1
22
2
TO _IN1-8
INPUT CIRCUIT IN1-IN8
Connection jack
grounded three
pole
0–10 V
0–10 V
0–10 V
0–10 V
PS+: 12V-24V
PS: GND
PS+: 12V-24V
DMX512-IN
DMX512-UNIVERSE
IN 1
IN 2
IN 3
IN 4
IN 5
IN 6
IN 7
IN 8
GND
PS+: 12V-24V
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
IN 16
GND
ANALOG IN 1
(0-10V)
ANALOG IN
8 (0-10V)
GND
RXD
TXD
RS232
TXD
RXD
GND
max. 2A/24V
EXTERNAL POWER SUPPLY +
EXTERNAL POWER SUPPLY GND
max. 2A/24V
max. 2A/24V
GND
max. 2A/24V
Balanced output left
Balanced output right
Balanced output left
Balanced output right
Channel 1
EXTERNAL
AMPLIFIER
Channel 8
EXTERNAL
AMPLIFIER
SMPTE TIME CODE IN
SMPTE TIME CODE OUT
ANALOG OUT 1, max. 15mA
ANALOG OUT 2, max. 15mA
ANALOG OUT 3, max. 15mA
ANALOG OUT 4, max. 15mA
GND: CONNECT TO PIN5 OR SHIELD
Example for LED connection
if output is used in PWM
mode
8 OPEN COLLECTOR- OR 8 PWM-
OUTPUTS
+
-
GND
+
-
GND
OUT: 1:GND, 2:DMX-, 3:DMX+
IN: 1:GND, 2:DMX-, 3:DMX+
ALWAYS MOUNT FLYBACK DIODE IN REVERSE
DIRECTION PARALLEL TO EACH INDUCTIVE LOAD!
RS232
REAR WIRING DIAGRAM FOR ProCommander LX
Max. 1,5A
Rel1
1N4007
D1
1
1
2
2
3
4
RELAY 9
IN 9-IN 16
100NF/50V
C1
10K
R2
10K
R1
D1
ZP D5V1
2
11
1
1
2
2
2
TO _AD-CONVERTER
INPUT CIRCUIT IN9-IN16
IN 1-IN 8
100NF/50V
C1
10K
R2 10K
R1
D1
ZP D5V1
2
1
1
1
1
22
2
TO _IN1-8
INPUT CIRCUIT IN1-IN8
Connection jack
grounded three
pole
0–10 V
0–10 V
0–10 V
0–10 V
PS: GND
PS+: 12V-24V
DMX512-IN
DMX512-UNIVERSE
GND
PS+: 12V-24V
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
IN 16
GND
ANALOG IN 1
(0-10V)
ANALOG IN
8 (0-10V)
GND
RXD
TXD
RS232
TXD
RXD
GND
EXTERNAL POWER SUPPLY +
EXTERNAL POWER SUPPLY GND
max. 2A/24V
GND
max. 2A/24V
Balanced output left
Balanced output right
Balanced output left
Balanced output right
Channel 1
EXTERNAL
AMPLIFIER
Channel 8
EXTERNAL
AMPLIFIER
+
-
GND
SMPTE TIME CODE IN
SMPTE TIME CODE OUT
RELAY 1
RELAY 2
RELAY 3
RELAY 4
Connection of internal relays
PS+: 12V-24V
PS+: 12V-24V
RELAY 5
RELAY 6
RELAY 7
RELAY 8
Connection of internal relays
ANALOG OUT 1, max. 15mA
ANALOG OUT 2, max. 15mA
ANALOG OUT 3, max. 15mA
ANALOG OUT 4, max. 15mA
GND: CONNECT TO PIN5 OR SHIELD
WIRING DIAGRAM FOR ProCommander LX
RELAY OPTION
Example for LED connection
if output is used in PWM
mode
8 OPEN COLLECTOR- OR 8 PWM-
OUTPUTS
+
-
GND
OUT: 1:GND, 2:DMX-, 3:DMX+
IN: 1:GND, 2:DMX-, 3:DMX+
ALWAYS MOUNT FLYBACK DIODE IN REVERSE
DIRECTION PARALLEL TO EACH INDUCTIVE LOAD!
RS232
Max. 1,5A

Other manuals for ProCommander LX

1

Other WEIGL Switch manuals

WEIGL ProCommander 2 Quick start guide

WEIGL

WEIGL ProCommander 2 Quick start guide

WEIGL ProCommander LTC User manual

WEIGL

WEIGL ProCommander LTC User manual

WEIGL ProCommander Quick start guide

WEIGL

WEIGL ProCommander Quick start guide

Popular Switch manuals by other brands

Velux INTEGRA KLI 310 Directions for use

Velux

Velux INTEGRA KLI 310 Directions for use

FW Murphy MLS Series Installation and operation manual

FW Murphy

FW Murphy MLS Series Installation and operation manual

Aeroflex GPSG-1000 Maintenance manual

Aeroflex

Aeroflex GPSG-1000 Maintenance manual

Hall Technologies FHD264 user manual

Hall Technologies

Hall Technologies FHD264 user manual

HP 2910 Series specification

HP

HP 2910 Series specification

Quintum DX Series DX8120 brochure

Quintum

Quintum DX Series DX8120 brochure

Endress+Hauser Liquipoint FTW 31 manual

Endress+Hauser

Endress+Hauser Liquipoint FTW 31 manual

Lenovo CE0128T Product guide

Lenovo

Lenovo CE0128T Product guide

BHI 1042 operating instructions

BHI

BHI 1042 operating instructions

Elko SOU-2 manual

Elko

Elko SOU-2 manual

Edge-Core ECS2000-26T installation guide

Edge-Core

Edge-Core ECS2000-26T installation guide

NETGEAR PROSAFE XS716E user manual

NETGEAR

NETGEAR PROSAFE XS716E user manual

Cisco Catalyst 8510 quick reference

Cisco

Cisco Catalyst 8510 quick reference

Cisco SR224R datasheet

Cisco

Cisco SR224R datasheet

Extron electronics VSW 2VGA A Setup guide

Extron electronics

Extron electronics VSW 2VGA A Setup guide

Seada HDS-891MV user manual

Seada

Seada HDS-891MV user manual

Smart-M SMTCP-2 installation manual

Smart-M

Smart-M SMTCP-2 installation manual

Hawking UH214 Specifications

Hawking

Hawking UH214 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.