NETWORK
FRONT WIRING DIAGRAM FOR ProCommander 2
Volume -
Volume +
Device address 1
(!ssi1#)
Device address 2
(!ssi2#)
Device address 3
(!ssi3#)
CAT5
CAT5
Daisy-Chain Connection for Pro-I/O
RS232-1 via Adapter-Cable
USB for Control and Configuration
Press button to store
permanently changes in menu
RS232-1/NET-IN
1: RS485-2 +
2: RS485-2 –
3: RS232-1 RXD
4: RS485-1 + (WEM-NET)
5: RS485-1 – (WEM-NET)
6: RS232-1 TXD
7: PS+ (DC24V/max. 50mA)
8: GND
RS232-2/NET-OUT
1: RS485-2 +
2: RS485-2 –
3: RS232-2 TXD
4: RS485-1 + (WEM-NET)
5: RS485-1 – (WEM-NET)
6: RS232-2 RXD
7: PS+ (DC24V/max. 50mA)
8: GND
1
1
8
8
RS232-1 shares RS485-1
RS232-2 shares RS452-2