e. LED Operation
• When the Green LED is "ON", it indicates Power ON and also that the input voltage and output
voltage is normal, the AVR is working.
• When the Yellow LED is “ON” and flash, it indicates that the regulator is in a delay status, the
output will be delayed.
• When the Red LED is "ON" and flash, it indicates the regulator is in a protection status.
f. Delay Operation
• This model is designed with a delay feature to protect appliances with compressors which should
not be switched on immediately after being switched off.
• The delay time is generally set at from 6/180 seconds. Please select delay or undelay before
switch on the AVR.
• When delay time has elapsed, delay LED will switch "OFF" and display will indicate the AC
output voltage.
g. Integrated Automatic Protection Circuit (IAPC)
• This model is equipped with a specially designed INTEGRATED
AUTOMATIC PROTECTION CIRCUIT.
• This very specialized and unique circuitry is now redesigned to automatically cut off the input
voltage whenever the input voltage is above the input voltage range, rendering full and
comprehensive protection to the regulator and connected appliances.
• When the input voltage returns to within Low and Normal ranges, the IAPC will automatically
switch the regulator back "ON" and also restore power to connected appliance.
h. Temperature Protection
• This AVR is equipped with a unique TEMPERATURE PROTECTION CIRCUIT designed to
protect the transformer, giving you longer and satisfactory use of the Regulator.
• If the internal temperature reaches the limit or above, the output power supply will cut "OFF"
automatically. There is no number to be shown in the display.
• When the internal temperature returns to normal range, output power will be restored. After the
delay time, the display will indicate output voltage.
i. High Output Voltage Protection
• This AVR is built in with a very specialized feature HIGH OUTPUT VOLTAGE PROTECTION
CIRCUIT.
• This special and unique circuitry is designed to protect connected appliances whenever the output
voltage is higher than the normal range.
• If the output voltage is over the normal range, the output power supply will cut "OFF"
automatically and the display will show "H". At the same time, the Red LED blinks.
• Once the input city power returns to normal range, the AVR will restore the output.
j. Low Output Voltage Protection
• When the output voltage is below the normal range, the output will be cut “OFF” automatically
and the display will show “L”. At the same time, the Red LED blinks
• Once the input city power returns to normal range, the AVR will restore the output to the load.