WatchNet WAC 1D2T MICRO/E User manual

Page 1of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
WatchNET Access Integrated Security Management Software
WAC 1D2T Micro Single Door Time Attendance Controller

Page 2of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Index
................................................................................................................................................................................
Revision History ....................................................................................................................................................3
Chapter1 - Introduction ........................................................................................................................................3
1.1 Summary.................................................................................................................................................3
1.2 Features..................................................................................................................................................4
1.3 Application Mode ...................................................................................................................................5
Chapter2 Wiring Diagram .....................................................................................................................................5
2.1 WAC 1D2T MICRO Appearance...............................................................................................................5
2.2 Wiring Diagram.......................................................................................................................................6
2.3 Lock Wiring Diagram...............................................................................................................................8
2.4 RS485 Net Bus.......................................................................................................................................10
2.5 TCP/IP Network.....................................................................................................................................10
Chapter3 Instructions .........................................................................................................................................12
3.1 Clock Configuration ..............................................................................................................................12
3.1.1 Edit Time ...................................................................................................................................12
3.2 Card Configuration................................................................................................................................13
3.2. 1 Add Card...................................................................................................................................13
3.2. 2 Delete Card...............................................................................................................................14
3.2.3 Del All Cards ..............................................................................................................................15
3.3 System Configuration............................................................................................................................15
3.3.1 Language Setting .......................................................................................................................15
3.3.2 Menu Password.........................................................................................................................16
3.3.3 Reader Settings .........................................................................................................................17
3.3.4 System Info Configuration .........................................................................................................17
3.3.5 Network Configuration..............................................................................................................18
3.3.6 Sleep Time.................................................................................................................................18
3.3.7 Board Info..................................................................................................................................19
3.4 Delete ...................................................................................................................................................19
3.4.1 Clear Event ................................................................................................................................19
3.4.2 Clear Card..................................................................................................................................20
3.4.3 Door Parameter Initialize ..........................................................................................................20
3.4.4 Clear All .....................................................................................................................................20
3.5 Door Open Mode..................................................................................................................................21

Page 3of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Revision History
Revision
Date
Author
Description of Changes
1.0
10/28/2013
Pradeep Kumaran
Manual Created.
1.1
11/30/2013
Octavio Colantonio
Updated Screen shoots.
1.1
03/24/2015
Peter Punzalan
Updated Manual
Chapter1 - Introduction
1.1 Summary
WAC 1D2T MICRO is a new outstanding T & A standalone controller with an OLED screen developed by
WATCHNET. The WAC 1D2T MICRO can work together with a fingerprint reader as T&A controller. The
employees will need to present their fingers on the Fingerprint Reader to complete attendance. The
OLED screen will display time and staff ID information. This system greatly improves the T&A simplicity
and offers cost saving on traditional tags. When the WAC 1D2T MICRO works as an access controller the
traditional keys are no longer needed. Employees can enter their space by flashing authorized cards. The
WAC 1D2T MICRO can by itself control a door and both in and out readers. At least one reader is needed
for one side and the other side can be controlled either by a reader or a REX Button. This system
provides a convenient and secured access environment and it also makes it possible for managers to
verify the attendance. The WAC 1D2T MICRO is compatible with a big range of applications including,
building management, enterprise management, government, military, prison etc..
Model Definition:
WAC 1D2T MICRO/E------Built in EM Card Reader

Page 4of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Supported Card Type:
E:EM Card;Exp EM4100,TK4100 Series.
H:HID Card;Exp: 1326、1386 Series.
M: Philips S50,Mifare-1 Compatible
1.2 Features
1. The WAC 1D2T MICRO is a new generation product comprising of an integrated keypad with
text display and a single door control and T&A. Its 3 flexible uses are as below.
T&A:The WAC 1D2T MICRO can directly communicate with host PC via RS485 or
TCP/IP managed by the WatchNET Access Software.
Single Door Controller:The WAC 1D2T MICRO can work as an access controller with
external readers for single door In/Out control.
Wiegand Reader with OLED Display:The WAC 1D2T MICRO can work as a reader
which outputs wiegand26 or wiegand34 signal while the OLED screen shows time and
card number.
2. 1 Rex Button output, 1 magnetic contact input, 1 Wiegand 26/34 input/output, 2 auxiliary
inputs, 2 relay outputs, 1 RS485 interface, 1 door bell interface.
3. Can connect to external Wiegand26/34 reader(keypad reader included),Entrance/exit can
be controlled by “Card/PIN” or “Card + PIN”.
4. Customized OLED LOGO display, menu with backlight, showing the name and card number
when reading a card.
5. Network (127 for RS485, no limit for TCP/IP), offline mode available. However need to
configure via the keypad before working offline.
6. The system can register 100 pcs Wiegand26/34 RFID cards and store 200000 events when it's
offline mode. When it comes to online mode, all data can be uploaded to host PC and 30000
cards can be registered.
7. Remote door control available, multiple incidents alarm functions, exp as door open timeout,
door close timeout, intrusion alarm, duress alarm, tamper alarm and fire alarm.
8. Specifications
Work Mode:
Card Mode;
PIN Mode;
Card/PIN Mode;
Card + PIN(interval time 8 sec)

Page 5of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Supported User Number:30000 pcs
PIN User Number:10
Communicate Frequency:
125KHZ:
E: EM;
13.56MHZ:
M: Mifare;
Read Range:3-15CM
Outputs:NC/NO,30VDC,5A
Power Supply:12VDC+10% ,200MA
Dimension:117mm (H) x 86mm (W) x 22mm (D)
1.3 Application Mode
3 Application Modes:
Standalone
Outdoor external reader, indoor WAC 1D2T MICRO
Indoor external reader, outdoor WAC 1D2T MICRO
Chapter2 Wiring Diagram
2.1 WAC 1D2T MICRO Appearance
Figure 2-1
LED (Green&Blue)
Backlight
Keypad
Door bell
Clock
Company Logo

Page 6of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
LED:
Blue LED:Power indicator
Green LED:Access Granted indicator(Relay turned on indicator)
Keypad:
NO.
Key
Description
NO.
Key
Description
1
1
Numeral 1
7
7
Numeral 7
2
2
Numeral 2
8
8
Numeral 8
3
3
Numeral 3
9
9
Numeral 9
4
4
Numeral 4
10
0
Numeral 0
5
5
Numeral 5
11
*
Cancel / Start
6
6
Numeral 6
12
#
Enter / Confirm
2.2 Wiring Diagram
Figure 2-2 Back of the reader
J7:Reader signal
output
J2:Door
bell
J4:TCP/IP interface
J6:Door Contact,Rex Button, Auxiliary
output
J5:Reader
interface
J3:RS485
interface
J8:Relay
output
J1:
Power

Page 7of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
TCP/IP interface, as shown below:
Figure 2-3
Icon
NO
Connection
Definition
Icon
NO
Connection
Definition
J1
1
GND
Power supply
J6
17
BUT
Magnetic, Rex
Button,
Auxiliary
output
2
12V
18
SEN
J2
3
BELL
Door bell
19
GND
4
BELL
20
IN1
J3
5
485-
485 interface
21
IN2
6
485+
22
GND
J4
7
RX-
TCP/IP
interface
J7
23
12V
Reader signal
output
8
RX+
24
D0
9
TX-
25
D1
10
TX+
26
LED
J5
11
12V
External
reader
interface
27
GND
12
D0
28
BUZ
13
D1
J8
29
NC1
Relay output
14
LED
30
COM1
15
GND
31
NO1
16
BUZ
32
NC2
33
COM2
34
NO2
2-1

Page 8of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Wiring Description:
J1: Power Supply
12V:DC 12V Positive
GND:Ground
J2: Door Bell
Normally, J2 outputs open signal if is not pressed.
If door bell is used, is pressed and J2 will outputs close signal to drive door bell rings.
J3: 485 Interfaces
An IC232 or RS485HUB is needed to connect host PC.
Customer can set all configurations when connected to host PC. Moreover user
authorization and exporting card events can also be done via AccessWatch3000.
J4: TCP/IP Interfaces
Available to use a switch or directly connect to host PC via Ethernet port.
Customer can set all configurations when connected to host PC. Moreover user
authorization and exporting card events can also be done via AccessWatch3000.
J5: External Reader Interfaces
12V:External reader power supply (Positive)
D0:Wiegand input
D1:Wiegand output
LED: Indicator connector
GND:Ground.
BUZ: Buzzer connector
J6: Door Contact, Rex Button, Auxiliary Input
BUT:Rex Button connector(GND for the other side).
SEN:Magnetic switch connector(GND for the other side).
GND:Negative(Public side).
IN1:Auxiliary input 1.
IN2:Auxiliary input 2.
J7: Built-in Reader Output
12V:Positive
D0:Wiegand output 0
D1:Wiegand output 1
LED: Indicator connector
GND:Negative(Public side).
BUZ:Buzzer connector
J8: Electronic Lock、Relay Output
Based on customized lock model.
2.3 Lock Wiring Diagram
J4: Relay Output(Lock Control)
As shown below.

Page 9of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Figure 2-4 Electronic Strike Lock
Figure 2-5 Magnetic Lock Fail safe
Figure 2-6 Cathode lock Fail secure

Page 10 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
2.4 RS485 Net Bus
The WAC 1D2T MICRO can communicate via half-duplex RS485 bus and up to a 1200m communication
distance. Terminals use series connection.
Please make sure power supply is in off state before wiring. This helps to avoid any damage that might
be caused to the device.
Figure 2-7
Twisted-pair:Twisted-pair are used to connect controller to controller. No GND is needed.
Series connection:Terminals are connecting via series connection. A multi-bus RS485HUB is needed
if customer needs parallel connection.
RS485 Single Point Ground:If controller transmission line is with shielding or needs ground line,
then all controllers’ transmission line can be grounded in either controller. Please note do not gather
all metal side to the GND of controller.
Terminal Resistance:Series connected at the end of the circuit.
2.5 TCP/IP Network
WAC 1D2T MICRO TCP/IP network
Figure 2-8
120Ω

Page 11 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
TCP/IP Connector
Figure 2-9
Sheet 2-2
Normal net cable(to switch)
图2-10
Crossed cable(to PC)
Figure 2-11
RJ45 NO.
Connection
1
TX+
2
TX-
3
RX+
6
RX-
8
←
1
8←1
8←1
8←1
8
←
1

Page 12 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Chapter3 Instructions
User Management, PIN management, Work mode and Time set are configured in the manage menu.
Menu structure is shown below.
Press * 39 # to enter manage menu when idle. In the main menu, “*” works as “cancel”, “#” works as
“confirm”, “3” works as “Up”, ”9” works as “down”.
3.1 Clock Configuration
3.1.1 Edit Time

Page 13 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186

Page 14 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186

Page 15 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186

Page 16 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186

Page 17 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
3.3.4 System Info Configuration

Page 18 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
3.3.5 Network Configuration
3.3.6 Sleep Time

Page 19 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
3.3.7 Board info

Page 20 of 21 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Table of contents
Other WatchNet Controllers manuals