Wellav Technologies SMP180 User manual

SMP180 IRD Quick Installation Guide V1.1-N
SMP180 Integrated Digital Receiver
Quick Installation Guide

SMP180 IRD Quick Installation Guide V1.1-N
1.InstallationInstruction
1.1 Mounting unit to a 19” rack
When selecting the installation site, try to comply with the following:
zProtective Ground - The protective ground lead of the building's electrical
installation should comply with national and local requirements.
zEnvironmental Condition - The installation site should be dry, clean, and
ventilated. Do not use this equipment where it could be at risk of contact with water.
To avoid electric shock, make sure the rack has been correctly grounded
before switching on the device.
To mount the SMP180 unit to a 19”/42U rack, please perform the following steps:
1. Make sure the mounted rack surface is stable and can support the size and weight of this
equipment.
2. For single unit mounting, use an “L” shape slide (not included in the package) to support
holding the unit if necessary, and fastened with appropriate screws to each side of the
chassis’ rails.
L-shape slide
3. For group pile up (no space between each unit), the unit should be placed on a flat
holding bracket. No more than 5 units for each group, and leave at least one unit space
PIC-1.1-1 Grounding Jackscrew (must be connected to the rack housing)

SMP180 IRD Quick Installation Guide V1.1-N
between each group to ensure good air ventilation.
PIC-1.1-2
1.2 Wiring Connection
Before setting up the connection, please turn off the equipment and all other
connected external devices. The equipment and all connected external devices are
required grounded. Turn on the devices only after the wiring connection is completed.
Otherwise the device may be damaged.
Follow the below connection diagram to set up cable connection:
PIC-1.2-1
zSet up cable connection for input signal: either the LNB input (area 1), ASI input (area 2)
or TS/IP input (area 4)
zSet up cable connection for output signal: either through ASI (area 3) or TS/IP (area 4)
zSet up connection for network management control: shown in area 5.
1 2 3
4
5

SMP180 IRD Quick Installation Guide V1.1-N
In order to ensure a smooth communication between the management PC and
the equipment, please separate the connection of management port and TS/IP output
port to different switch. The switch with management port connected should be
without large data processing.
The TS/IP port can work for input and output simultaneously. User only needs
to connect one RJ45 cable to the TS/IP port of the device.
1.3 Power Connection
Connect this equipment only to the power sources that are identified on the
equipment-rating label normally located close to the power inlet connector(s).
Always pull on the plug or the connector to disconnect a cable. Never pull on the
cable itself.
To protect your valuable interests and services, equipping a UPS
(Uninterrupted Power Supply) and an AVR (Automated Voltage Regulator) to the
system is highly recommended.

SMP180 IRD Quick Installation Guide V1.1-N
2.OperationInstructions
2.1 Powering Up & Initializations
Before powering-up the device, make sure that all cabling is correctly
connected (refer to chapter 1.2). The device is correctly connected to the power inlet
and grounded.
Switch on the equipment through the back power switch, the unit is powered up and start the
initialization.
The LCD screen is lighted up, and display information as following:
PIC-2.1-1
The initialization takes about 30 seconds to complete.
If the unit fails to initialize and hangs at the “booting” screen, swtiching off the
device and then powering up again may help. If the device still fails to initialize,
please contact your service representative for help.
The input/output indicator LEDs turn red after successful initialization because
of signal unlocking. After configuration on the device, corresponding LEDs shall
show correct status.
2.2 Network Connection Setup
2.2.1 Navigation Keys Operation Instruction
Use the 6 navigation keys on front panel: Up / Down / Left / Right / Menu / Ok to
SMP180
System

SMP180 IRD Quick Installation Guide V1.1-N
enter the configuration menu.
zEnter “Menu”:
Press “MENU” button to enter main menu.
zExit Menu/Back to parent Menu
Upon completion of configuration settings, press “MENU” button until you go back
to the Parent Menu.
You can also go back to Parent Menu directly by pressing “ESC” button once.
zEnter Sub-Menu
Press MENU button to enter main menu.
Select a sub-menu by pressing arrow UP and arrow DOWN button.
Press OK button on the selected sub-menu.
zTo change parameter
Step 1: Enter main menu by pressing MENU button.
Step 2: Scroll sub-menu by pressing arrow UP and arrow DOWN button, and press
OK button to change the selected sub-menu.
Step 3: To change parameter settings, press arrow RIGHT and arrow LEFT button
to move the cursor in which change must be made.
Press arrow UP button and arrow DOWN to input / select an appropriate setting,
then press OK button to save.
2.2.2 Check Out and Change the Default IPAddress
zStep 1: check out the IP.
zStep 2: change the IP, gateway and subnet mask on the front panel by navigation keys
under ‘System’ sub-menu to make it in the same network section as the management
PC. You can also change it in the ‘System’ tab through Network Management System
(as PIC-2.2-1).
zStep 3: the equipment will reboot automatically and apply with the new IP address.
zStep 4: ping the new IP on PC to check the connectivity.
zStep 5: After IP changes and successful connection setup between the device and
management PC, the IP address modification can be done on WEB UI afterwards.

SMP180 IRD Quick Installation Guide V1.1-N
PIC-2.2-1
2.2.3 Configuration through NMS
Accessing the equipment through NMS can be very convenient for remote
configuration of the equipment. Relative to the front panel settings, NMS operation
can provide a more user-friendly man-machine interface, and less limits in space. For
quick installation, NMS operation is highly recommended. In this installation guide,
operation instruction is based on NMS style. For front panel operation instruction,
please refer to product user manual.
zInstall the NMS Tool
Unpack the accessory CD, and put it on a PC CD/DVD driver;
Copy the NMS program on the CD to any folder of the management PC;
Use mouse to double click the NMS icon and run the NMS program.
PIC-2.2-2
zFirst Time Log On
For first time log on, User Name and Password are required. Default User Name
and Password are “admin”.

SMP180 IRD Quick Installation Guide V1.1-N
PIC-2.2-3
User can change the password after log on the device. Please refer to chapter
2.3.1 of this document for the details.
Choose “Remember Me” if user wants to directly log on the NMS without inputting
the user name and password.
Select “Login” to log on the device.
Possible reasons for unsuccessful log on:
IP address/network mask/gateway doesn’t match with the management PC.
User name/password is wrong.
The device is connected in the wrong interface.
zMain Interface Introduction
After successful log on, the following screen will display:

SMP180 IRD Quick Installation Guide V1.1-N
PIC-2.2-4
The NMS main interface can be divided into four areas according to its functionality.
(1) Toolbar: It includes shortcut to change password and save settings etc.
(2) Equipment list: If more than one piece of equipment is connected to the NMS, the
equipment will be listed in this area by its IP address.
(3) Parameter setting and configuration area: The parameters of the equipment are
shown and configured here by selecting different tabs. This is the main operation area
of the NMS. It shares same 6 tabs including ‘Status’, ‘Program Info’, ‘System’,
‘License’, ‘Upgrade’ and ‘Log’. Specific to each model, the detailed module
configuration tab will be different.
(4) Event information window.
2.3 Quick Configuration on Key Parameters
2.3.1 Change the password
In the ‘Toolbar’ tab, click ‘Password’, you can change the password as below:

SMP180 IRD Quick Installation Guide V1.1-N
PIC-2.3-1
2.3.2 Check ‘Status’ tab
By selecting this item the NMS displays the current system operation data status of the
equipment. User can swtich between tab under the “Status” to check the current working
status of the equipment.
PIC-2.3-2
2.3.3 Configure parameters of signal input modules
zTuner
DVB-S/S2 Receiver