WELLTEC Bedal 3S User manual

Welltec-UM-Bedal_170329 Rev.03
User Manual Bedal 3S

Ver. 03
User Manual Bedal 3S
Introduction
Installation
1
Operation
Introduction 2
Operating Condition 3
Contents
Enclosed Parts 8
About Bedal 4
Measuring Dimension & Weight 18
Specifications 5
Precautions
Error Code 21
Description of Units 6
H/W Installation 9
Measurable / Non-Measurable Items 22
Warranty 23
S/W Installation 16
Interface Flow 17

Ver. 03
User Manual Bedal 3S
2
Welcome!
Thank you very much for selecting Bedal 3S.
This manual is prepared to provide you with guidelines on how to properly operate and
maintain the Bedal 3S. Please read this user manual before operating in order to prevent
unexpected malfunction or damage. Please refer to the manual carefully and follow the
instruction.
Copyright
Any of the contents should not be copied, re-printed or translated into other languages
without Welltec’s approval.
Introduction
Introduction

Ver. 03
User Manual Bedal 3S
Operating Condition
3
Caution: Serious bodily injury or mechanical damage may result from
insufficient attention to or incorrect compliance with warning
messages with this symbol.
●Do not attempt to disassemble or reassemble the machine. It may cause an electric
shock or mechanical problem.
●Disconnect the power immediately if liquid or a foreign object enter the inside of the
machine.
●Do not input metal or inflammable material into the inlet.
●Remove the power cable while moving the machine.
●Where the wind is directly affected to the machine, it may cause measurement errors
due to wind, and measurement time could get longer.
●Be careful not to place objects that exceed the allowable load of the unit, as this will
cause the unit malfunction. (Even if no power is applied, overload will cause a
damage)
●Do not install the machine on the place as below.
- Near window or places exposed to direct sunlight.
- Where vibration is detected or unstable place (causing measurement errors)
- Where temperature changes suddenly or poorly ventilated.
- Places exposed to hot or cold air directly. (not office circumstance)
- Not solid enough or weak floor.
- Near excessive electromagnetic waves are generated (causing measurement errors)
- Where strong winds blow (measurement time may be increased)
●Temperature: 5℃ ~ 40℃
●Humidity: ~85%RH, Non-Condensing.
Introduction

Ver. 03
User Manual Bedal 3S
About Bedal
4
Bedal 3S is an electronic Dimensional Scanner that automatically measures the
weight and dimension of your parcel. It transmits captured dimension, weight,
image and other data to the host like Windows based PC, Tablet or TCP/IP linked
Server. Not working as a standalone, Bedal 3S is an Input Device required to be
linked to your computer. Bedal 3S will pay for itself, enjoy automatic measuring and
experience your time and cost saving!
Introduction

Ver. 03
User Manual Bedal 3S
Specifications
5
Contents Specifications Remark
Function Measuring Dimension & Weight
Weight
Measure
Automatic 0~30Kg
Division
Less 5Kg
2g
Over 5Kg
5g
Tolerance
Less 5Kg
±2g
Over 5Kg
±5g
Dimension
Measure
Automatic
Width 3"(75mm)~15.5"(390mm)
Regular
Length 3"(75mm)~17"(430mm)
1 side extendable to 29" (735mm)
Height 1"(25mm)~19"(480mm)
Division W/L/H 5 mm
Tolerance W/L/H ±10 mm
UI Control Unit PC (Window) / Tablet PC PC is not included
Interface
USB Hub Port USB 2.0 (A type) x 3ea
USB Host Port USB 3.0 (A type) x 1ea
Tablet PC / PC USB 2.0 (B type) x 1ea
RS-232C D-SUB 9Pin (Male) x 1ea Firmware Update
Port
D-SUB 9Pin (Female) x 1ea
Measuring Time Maximum 4.5 Seconds Regular
Ethernet IEEE 802.3 10/100Mbps Ethernet Port (RJ-45) Lan
Power Source 90~240 VAC, 50/60Hz (24V DC 1A)
Power Consumption 17W Max
Product Dimension 557.8 X 566.7 X 846.8 (mm, L*W*H) Standard
874 X 566.7 X 846.8 (mm, L*W*H) 1 Side Extended
Product Weight 23kg (28kg, including package)
* Specification is subject to be revised without notice.
Introduction

Ver. 03
User Manual Bedal 3S
Description of Units
6
Speaker
Sensor (Length Measure)
*Extendable
Camera
Object Detect Sensor
Weight Measurement
Sensor (Width Measure)
LED
· LED: Display device operation status.
· Speaker: Voice instruction of operation.
· Object Detect Sensor: Start measuring the weight and dimension of the object by sensing the
object placed on the Weight Measurement.
· Sensor (Height Measure): Measure the height of object.
· Sensor (Length Measure): Measure the length of object. (1 side extendable)
· Sensor (Width Measure): Measure the width of object.
· Weight Measurement: Measure the weight of object.
· Camera
Front
1
Sensor (Height Measure)
Introduction

Ver. 03
User Manual Bedal 3S
7
Rear
2
Port Power S/W
Serial No.
DC Power
Jack
USB 2.0
A Type
USB B Type
D-sub (M)
D-sub (F)
Lan (RJ45)
USB 2.0 USB 3.0
* Printer will use the power source separately.
* PC will use PC Lan Port for internet connection, Tablet PC need Wi-Fi (customer installation).
* PC (control) or server need to be able to download operation program.
* D-Sub (M/F) is for Firmware Update.
* Display Port is for exterior display unit. (optional)
* USB 3.0 (Host Port) is used as printer port when Bedal 3S is the host of the configuration.
Display Port
Description of Units
Introduction

Ver. 03
User Manual Bedal 3S
8
Check out all parts are included after unpacking.
1
Enclosed Parts
Installation
①Main Body ②Upper Unit
●Main Units
●Adaptor & Cable
①DC Adaptor ②Power Cable
●Screws
①Truss M4X10L * 6pcs
③USB Cable (A-B)

Ver. 03
User Manual Bedal 3S
9
After unpacking, unscrew 4 bolts marked as circle in the below picture &
remove the rear cover. (keep the bolts)
1
H/W Installation
Installation

Ver. 03
User Manual Bedal 3S
10
Assemble the Upper Unit to Post (Main Body) as below picture. Harness & USB
connector must go through the Post.
2
Upper Unit
Harness /
USB Connector
Post (Main Body)
Be careful your hands not to be caught in while assembling Upper Unit
to the Post.
H/W Installation
Installation

Ver. 03
User Manual Bedal 3S
11
Fix the Upper Unit & the Post with Truss M4X10L * 6pcs. (included)
3
Connect the USB connector (Upper Unit - Main Body) as below picture.
4
H/W Installation
Installation

Ver. 03
User Manual Bedal 3S
12
Connect Harness (Upper Unit) to the Port as below picture.
5
Arrange Harness and USB connector using the clamp as below picture.
6
H/W Installation
Installation

Ver. 03
User Manual Bedal 3S
13
Re-assemble the rear cover, screw 4 points marked as circle in the below picture
with 4 bolt (unscrewed #1)
7
Connect PC / Tablet PC / Printer & other components to the rear port.
8
* Refer to the Page.7 - Description of Units (Rear)
H/W Installation
Installation

Ver. 03
User Manual Bedal 3S
14
Please check the horizontal position of the installation site by using the leveling
system.
If the level does not match, use the leveling screw at the bottom of the unit to
level it. (total 3 point)
If the product is not leveled, errors may occur when measuring the
weight and dimension of the object.
9
10
H/W Installation
Installation

Ver. 03
User Manual Bedal 3S
15
Connect Power Cable to the DC Power Jack.
After connecting the power, turn on the power switch.
Please be sure to turn off the power after completing the acceptance.
If turning off the power during operation, it causes unexpected errors.
11
12
Please make sure to use only provided adapter. Using other adapter
may cause the unit malfunction.
When Bedal 3S is turned on, initialization will be started. After initialization, the green
light on LED (Upper Unit) turns on and ready for measurement (takes 4~5 seconds)
H/W Installation
Installation

Ver. 03
User Manual Bedal 3S
16
S/W Installation
Installation
www.bedalsmart.com
Please visit the below website “Bedal Smart Link” to download Bedal Smart
Connect Software & User Manual.
1
1) Bedal SmartConnect Software Download.
2) Bedal SmartConnect Software Manual.
3) Hardware / Software FAQ & Customer Support
and more information about Bedal 3S & Bedal SmartConnect will be updated on the website.
Install the Software following the S/W Manual
2

Ver. 03
User Manual Bedal 3S
Interface flow
17
PC
1
Tablet PC
2
USB
USB (USB to Serial)
USB
Installation
USB (USB to Serial)

Ver. 03
User Manual Bedal 3S
Measuring Dimension & Weight
18
Measure the object as below picture.
1
①Put the object on the Bedal 3S. Push to the Object Detect Sensor for operating activation.
②Bedal 3S automatically measures the dimension and weight of the object.
Operation
* Green light flashes during measurement and a beep sounds when measurement is complete.

Ver. 03
User Manual Bedal 3S
19
③Extend the Length Measurement Unit for large object as below picture.
(extendable to 29“ / 735mm max)
After using the Length Measurement Unit extension, please reduce the
Length Measurement Unit back to original position.
* Extend the Length Measurement Unit to the end. If not, Bedal 3S doesn’t detect the object &
beep sounds.
* Place the object to cover the sensors while Length Measurement Unit is extended.
* Bedal 3S is not able to detect small object when Length Measurement Unit is extended.
Please purchase <Extend Guide –optional> if you want to keep operating Bedal 3S in Length
Measurement Unit extension.
Measuring Dimension & Weight
Operation
Table of contents
Other WELLTEC Scanner manuals
Popular Scanner manuals by other brands

ClearClick
ClearClick Virtuoso 2.0 Quick start guide & user manual

Hyco
Hyco W28LD Series user manual

Fujitsu
Fujitsu ScanSnap iX1600 Advanced operation guide

Canon
Canon 4400F - CanoScan - Flatbed Scanner quick start guide

Colortrac
Colortrac SmartLF Gx25m Service manual

Epson
Epson 3170 - Perfection Photo user guide