Any damage on the hose could alter the electronic alarms linked to the airflow.
The length of the hose must not be altered.
Any modification of the length of the hose would :
•Alter the calibration of the blower unit and alter the alarms levels
•Void any warranty claims
Airflow tester
- On a weekly basis, check the airflow calibration of the Airkos blower unit
Remove the air hose
Insert the airflow tester directly into the hose connection on the top of the
blower unit.
Use a fully charged battery
Use a new filter and new prefilter
Select the minimum 180l/m airflow
The blue ball must be above the minimum reference, as shown below.
If the blue ball is below the minimum level, please contact your local dealer.
Proscriptions
Never use the Airkos blower unit :
- in an enirionment with less than 17% oxygen
- in a confined area
- nearby flames and projections
- without any filter and prefilter
Contact Details
Weltek
Té : 04 37 85 54 27
Fax : 04 78 55 64 68
www.weltek.fr
Airkos Maintenance