Wen 56450iX User manual

4500-WATT
INVERTER GENERATOR
Instruction Manual
IMPORTANT: Your new tool has been engineered and manufactured to WEN’s highest standards for dependability,
ease of operation, and operator safety. When properly cared for, this product will supply you years of rugged,
trouble-free performance. Pay close attention to the rules for safe operation, warnings, and cautions. If you use
your tool properly and for its intended purpose, you will enjoy years of safe, reliable service.
NEED HELP? CONTACT US!
Have product questions? Need technical support? Please feel free to contact us:
For replacement parts and the most up-to-date instruction manuals, visit WENPRODUCTS.COM
MODEL 56450iX

CONTENTS
WELCOME 3
Specifications................................................................................................... 3
Introduction ..................................................................................................... 4
SAFETY 5
Safety Information ........................................................................................... 5
Generator Safety Warnings .............................................................................. 6
BEFORE OPERATING 9
Unpacking & Packing List................................................................................ 9
Know Your Inverter Generator........................................................................ 10
Generator Preparation.................................................................................... 12
17
Starting Your Generator ................................................................................. 17
Using Your Generator..................................................................................... 19
Stopping Your Generator ............................................................................... 26
Maintenance................................................................................................... 27
Transportation & Storage............................................................................... 34
Troubleshooting Guide................................................................................... 35
Wire Diagram................................................................................................. 36
Exploded View & Parts List............................................................................ 37
Warranty Statement ....................................................................................... 48
OPERATION & MAINTENANCE
To purchase accessories for your tool, visit WENPRODUCTS.COM
Magnetic Oil Dipstick (Model No. 55201)
WEN Parallel Connection Kit
Weatherproof Generator Cover (Model No. 56310iC)
High-Altitude Kit (Part No. 56450i-HA36 & 56450i-HA68)
2

SPECIFICATIONS
GENERATOR
ENGINE
3
Surge Wattage 4500 Watts
Rated Wattage 3500 Watts
Rated Voltage AC: 120V
DC: 12V (Cigarette Lighter), 5V (USB)
Rated Amperage 29.16A
Phase Single
Frequency 60 Hz
Decibel Rating 58 dB
Product Dimensions
Length: 23.2 in. (590 mm)
Width: 18 in. (456 mm)
Height: 20.1 in. (511 mm)
Product Net Weight 99.2 lbs (45 kg)
Engine Type 4-Stroke, OHV, Single Cylinder with Forced Air Cooling
System
Engine Displacement 212cc
Engine Speed 3600 RPM
Fuel Tank Capacity 2.2 US Gallons (8.50 L), 87 Octane Minimum
Oil Capacity 18.6 fl. oz. (0.55 L)
Half-Load Run Time 8.5 Hours
Lubrication System Splash Lubrication
Spark Plug Type NGK BPR6ES / Torch F6RTC
Spark Plug Gap 0.7 - 0.8 mm (0.028 - 0.031 in.)
Spark Plug Torque 1/2 - 3/4 turn after gasket contacts base or 15 ft-lbs

INTRODUCTION
Thanks for purchasing the WEN 4500-Watt Inverter Generator. Refer to the illustration below for the location of the
serial number on the side of the engine and on the main specifications label. Record the generator information in the
spaces provided below. If assistance for information or service is required, please contact customer service by call-
ing 1-800-232-1195, M-F 8-5 CST; you will be asked to provide the following generator information when calling.
Generator Model Number: 56450iX
Date of Purchase: ______________________________________________
Purchased From:_______________________________________________
Serial Number: ________________________________________________
TO MAXIMIZE THE LIFESPAN OF YOUR GENERATOR: We recommend running your generator at least once a
month for 20 to 30 minutes. Start the generator according to the instructions and plug a small load in to make
sure the outlet is producing electricity.
SERVICE RECORD
Record the service dates of your generator in the chart below. Please perform maintenance checks and operations
according to the “Maintenance” section of the manual.
Service Record Date Date Date Date Date Date
Change Oil
Change Spark Plug
Clean Fuel Tank
Clean Air Cleaner
Clean Spark Arrestor
Serial NumberSerial NumberSerial Number
4
Serial NumberSerial NumberSerial Number

SAFETY INFORMATION
SAFETY INTRODUCTION
Safety is a combination of common sense, staying alert, and knowing how your tool works. This manual contains
important information regarding the generator’s potential safety concerns, as well as preparation, operation, and
maintenance instructions. Before operating this generator, be sure to read and observe all warnings and instructions
both on the generator labels and in this instruction manual. Failure to follow all instructions listed below may result
in personal injury.
NOTE: The following safety information is not meant to cover all possible conditions and situations that may occur.
WEN reserves the right to change this product and specifications at any time without prior notice.
At WEN, we are continuously improving our products. If you find that your tool does not exactly match this manual,
please visit wenproducts.com for the most up-to-date manual or contact customer service at 1-800-232-1195, M-F
8-5 CST.
Keep this manual available to all users during the entire life of the tool and review it frequently to maximize
safety for both yourself and others.
SAVE THESE SAFETY INSTRUCTIONS.
SAFETY SYMBOLS
The purpose of following safety symbols is to attract your attention to possible dangers. The safety symbols, and
their explanations, deserve your careful attention and understanding. The safety warnings do not by themselves
eliminate any danger. The instructions or warnings they give are not substitutes for proper accident prevention
measures.
NOTICE REGARDING EMISSIONS
Engines that are certified to comply with U.S. EPA emission regulations for SORE (Small Off Road Equipment), are
certified to operate on regular unleaded gasoline, and may include the following emission control systems: (EM)
Engine Modifications and (TWC) Three-Way Catalyst (if so equipped).
QUESTIONS? PROBLEMS?
In order to answer questions and solve problems in the most efficient and speedy manner, contact customer
DANGER: indicates a hazard, which, if not avoided, will result in death or serious injury.
WARNING: indicates a hazard, which, if not avoided, could result in death or serious injury.
CAUTION: indicates a hazard, which, if not avoided, might result in minor or moderate injury.
CAUTION! when used without the alert symbol, indicates a situation that could result in damage to the machine.
WARNING! Before operating the generator, make sure to read all safety warnings and all instructions. Failure
to follow the warnings and instructions may result in electric shock, fire or serious injury.
5

GENERATOR SAFETY WARNINGS
DANGER! CARBON MONOXIDE
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide (CO). This
is a poison gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even
if you cannot smell the exhaust, you could be breathing CO.
NEVER use a generator inside homes, garages, crawl spaces, or other partially enclosed areas. Deadly levels
of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply
enough fresh air. ONLY use a generator outside and far away from windows, doors, and vents. These openings
can pull in generator exhaust.
Even if you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-
backup CO alarm in the home. If you start to feel sick, dizzy, or weak after the generator has been running, move
to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.
WARNING! RISK OF EXPLOSION. HIGHLY FLAMMABLE: This generator may emit highly flammable and
explosive gasoline vapors, which can cause severe burns or even death, if ignited. A nearby open flame can lead
to explosion even if not directly in contact with gasoline.
• Do not operate near open flame, heat, or any other ignition source. Do not smoke near the generator.
• Always operate on a firm, level surface.
• Always turn generator off before refueling. Allow generator to cool for at least 2 minutes before removing
fuel cap. Loosen cap slowly to relieve pressure in tank.
• Do not overfill fuel tank. Gasoline may expand during operation. Do not fill to the top of the tank. Allow for
expansion. Always check for spilled fuel before operating.
• If fuel spills, move the generator at least 30 feet away from the spill and wipe clean any spilled fuel before
starting the engine.
• Empty fuel tank before storing or transporting the generator.
WARNING! If this generator is used as a supply for a building’s wiring system, the generator must be in-
stalled by a qualified electrician and connected to a transfer switch as a separately derived system in accordance
with all applicable laws and electrical codes and the National Electrical Code, NFPA 70. The generator shall be
connected to a transfer switch that switches all conductors excluding the equipment grounding conductor. The
frame of the generator shall be connected to an approved grounding electrode.
CALIFORNIA PROPOSITION 65 WARNING: This product contains chemicals and produces exhaust known
to the State of California to cause cancer, birth defects and other reproductive harm.
6

GENERATOR SAFETY WARNINGS
OPERATING ENVIRONMENT
1. Using a generator indoors can kill you in minutes.
Only use a generator outside and far away from win-
dows, doors and vents.
2. Do not smoke near the generator.
3. Do not operate near open flame, heat, or flammable
materials. This generator may emit highly flammable
and explosive gasoline vapors, which can cause severe
burns or even death if ignited. A nearby open flame can
lead to an explosion even if it isn’t directly in contact with
gasoline.
4. Do not expose the generator to rainy or wet con-
ditions; doing so significantly increases the risk of
electrical shock. Never handle the generator, electronic
devices, or any cord while standing in water, while bare-
foot, or when hands or feet are wet.
5. Always operate the generator on a dry, firm, level
surface.
6. The generator should have at least 5 feet of clear-
ance from buildings or other equipment during opera-
tion.
7. Do not allow children or non-qualified persons to
operate the generator.
GENERATOR PREPARATION
1. Always ground the generator before using it to maxi-
mize safety (see “Ground the Generator” section).
2. Do not overfill fuel tank, as gasoline may expand
during operation. Do not fill to the very top of the tank.
Leave room for gasoline expansion. Always check for
spilled fuel before operating.
3. If any part of the generator, electrical device or pow-
er cord is broken, damaged, or defective, make sure
it is repaired or replaced before operation. Service
should only be performed by a qualified technician. Do
not use receptacles or cords that show signs of damage,
such as broken or cracked insulation.
4. Use a ground fault circuit interrupter (GFCI) in highly
conductive areas such as metal decking or steel work.
Extension cords with in-line GFCIs are recommended for
these operations to maximize safety.
5. If connecting the generator to a building’s electri-
cal system for standby power, you MUST consult a
qualified electrician and install a transfer switch. Such
connections must comply with local electrical laws and
codes. Failure to comply can create a back-feed, which
may result in serious injury or death to utility workers.
6. Never modify the generator in any way. Modifying
or using the machine for any other purpose for which it
is not designed may result in serious injuries, machine
damage and voiding of the warranty.
GENERATOR OPERATION
1. Only use the generator for its intended purposes.
Modifying or using the generator for operations for
which it was not designed may cause hazards and per-
sonal injury.
2. Do not touch bare wires or receptacles (outlets).
3. Do not exceed the wattage capacity of the generator
by plugging in more electrical devices than the unit
can handle. This could damage the generator and/or
connected electrical devices. Check the operating volt-
age and frequency requirements of all electrical devices
prior to plugging them into the generator.
Generator safety warnings continue on the next page.
WARNING! Do not let comfort or familiarity with the product replace strict adherence to product safety rules.
Failure to follow the safety instructions may result in serious personal injury.
7

GENERATOR SAFETY WARNINGS
WARNING! Do not let comfort or familiarity with the product replace strict adherence to product safety rules.
Failure to follow the safety instructions may result in serious personal injury.
4. Allow generator to run for several minutes before
connecting electrical devices. Do not start or stop en-
gine with electrical devices plugged in to the receptacles.
Failure to do so could damage the generator and/or con-
nected electrical devices.
5. Do not turn on electrical devices until after they are
connected to the generator.
6. Generators vibrate in normal use. During and after
the use of the generator, inspect both the generator as
well as extension and power supply cords for damage
resulting from vibration.
7. Do not touch hot parts. This generator produces heat
when running. Temperatures near exhaust can exceed
150ºF (65ºC). Allow generator to cool down after use be-
fore touching engine or areas of the generator that be-
come hot during use.
8. Turn off all connected electrical devices before stop-
ping the generator.
9. Always turn generator off before refueling. Allow
generator to cool for at least 2 minutes before removing
fuel cap. Loosen cap slowly to relieve pressure in tank.
10. Turn the engine switch to “OFF” position when the
engine is not running.
11. Empty fuel tank before storing or transporting the
generator. Do not store generator or gasoline near fur-
naces, water heaters, or any other appliances that pro-
duce heat or have automatic ignitions. Store the genera-
tor and fuel away from sparks, open flames, pilot lights,
heat and other sources of ignition.
12. Always wash hands after handling generator.
CAUTION: Misuse of this generator can damage it or
shorten its lifespan.
TO MAXIMIZE THE LIFESPAN OF YOUR GENERATOR: We recommend running your generator at least once a
month for 20 to 30 minutes. Start the generator according to the instructions and plug a small load in to make
sure the outlet is producing electricity. If you do not run it often, it will greatly shorten the generator’s lifespan
and void the warranty.
8

Assembly Tools
Spark Arrestor Tools Accessories
UNPACKING
With the help of a friend or trustworthy foe, such as one of your in-laws, carefully remove the generator from the
packaging and place it on a sturdy, flat surface. Make sure to take out all contents and accessories. Do not discard
the packaging until everything is removed. Check the packing list below to make sure you have all of the parts and
accessories. If any part is missing or broken, please contact customer service at 1-800-232-1195 (M-F 8-5 CST),
PACKING LIST
UNPACKING & PACKING LIST
Components
Generator
14mm / 17mm
Wrench
Wrench Screwdriver
Handle Funnel Cup Funnel Tube
8mm / 10mm
Wrench
9

KNOW YOUR INVERTER GENERATOR
TOOL PURPOSE
Inverter Generators provide you with clean and quiet power, when and where you need it most. Refer to the fol-
lowing diagrams to become familiarized with all the parts and controls of your Generator. The components will be
referred to later in the manual for assembly and operation instructions.
GENERATOR
Fuel Cap
Carrying Handle
Control Panel
Transportation Handle
Recoil Start
Oil Access Cover
Ventilation Slots
Overload Indicator (Red)
Output Indicator
(Green) Low Oil Indicator (Yellow)
Fuel IndicatorLoad Indicator
Digital Display
(Voltage, Frequency, Run Time, Maintenance Alert at 50 hours)
10

VOLTAGE FREQUENCY TIME
KNOW YOUR INVERTER GENERATOR
CONTROL PANEL
1 3 4 5
6
7
810111314
1. Data Meter with Indicator Light
2. Overload Reset
If the overload light is ON, press this button to reset.
3. CO WATCHDOG Carbon Monoxide Monitor
Measures the accumulation of poisonous CO gas while
the generator is running. If the level of CO gas gets too
high, the CO Watchdog system will automatically shut
down the generator. See p. 24 for more information.
4. Eco-Mode Switch
Turn ON to increase fuel economy and runtime when the
load is below 2625W (75% load).
5. Parallel Connection Port
Connect two WEN inverter generators through a parallel
connection kit for a higher output.
6. DC 12V Cigarette-Lighter Style Receptacle
7. DC 5V USB Outlet
8. Grounding Nut
Ground generator to reduce risk of electric shock.
9. DC Circuit Breaker (10A)
10. AC 120V NEMA TT-30 Receptacle (29.16A)
11. AC Circuit Breaker for NEMA 5-20R (20A)
12. AC 120V NEMA 5-20 Duplex Receptacles (20A)
13. Manual Shutoff Button
Push down for 10 sec. to shutoff generator manually.
14. 3-in-1 Switch
Turn switch to choke, run, and automatically shut off the
generator.
11
2
912

GENERATOR PREPARATION
REMOVING THE MOUNTING PLATES
Your generator is shipped with four mounting plates that secure the engine to the generator housing in order to
prevent machine damage during shipping. Make sure to remove the four mounting plates before operating your
generator.
To remove the mounting plates:
1. With the help of another person, place generator on an elevated platform such as table or workbench. Make sure
the generator is stable. Do not to tilt the generator as there may be remaining oil inside the crankcase from testing.
2. Remove the four nuts (Fig. 1 - 3) and mounting plates (Fig. 1 - 2) from the generator's baseplate (Fig. 1 - 1).
3. Follow the instructions in the following pages to prepare your generator for starting.
Fig. 1
12
2
3
3
2
2
3
3
12

Synthetic 5W-30
30W
10W-30
GENERATOR PREPARATION
The following section describes the necessary steps to prepare the generator for use. If you are unsure about how
to perform any of the steps, please call (800) 232-1195 M-F 8-5 CST for customer service. Failure to perform these
steps properly can damage the generator or shorten its life.
STEP 1 - ADD / CHECK OIL
The generator is shipped without oil. User must add the proper amount of oil before operating the generator for the
first time. The oil capacity of the engine crankcase is 18.6 fl. oz. (0.55 L).
• 30W Engine Oil
Temperatures above 40°F
• 10W-30 Engine Oil
Temperatures between 0°F - 40°F
• Synthetic 5W-30 Engine Oil
All temperature ranges
ENGINE OIL RECOMMENDATIONS
Select good quality detergent oil bearing the American Petroleum Institute (API) service classifications SJ, SL,
or SM (synthetic oils may be used). Select the SAE viscosity grade of oil that matches the expected operating
temperature.
°F
°C
-20 0 20 32 40 60 80 100
40200
-20 -10 10
-30 30
To add oil, follow these steps:
1. Place the generator on a level surface. Make sure the en-
gine is off before adding or checking oil.
CAUTION: Keep the generator level! Tilting the generator
to assist in filling will cause oil to flow into the wrong
areas of the engine and cause damage.
2. Turn the oil access cover knob to the unlocked position,
and remove the access cover from the side panel. Unscrew
the oil dipstick from the engine (Fig. 2).
3. Using an oil funnel or appropriate dispenser, slowly add
oil into the oil fill, being careful not to overfill the unit. Fill the
crankcase to the upper fill line so you can visually see the oil
coming halfway up the oil fill threads (Fig. 3).
4. Reinstall the oil dipstick and firmly tighten it. Wipe clean
any spilled oil.
5. Reinstall the oil access cover. Turn the oil access cover
knob to the locked position to secure the cover in place.
Fig. 2
Fig. 3
Upper Level
Fill Line
Lower LevelLower Level
Fill LineFill Line
Lower Level
Fill Line
13

GENERATOR PREPARATION
STEP 1 - ADD / CHECK OIL (CONTINUED)
For subsequent operation, the oil level should be checked before each use, or after every 8 hours of operation. The
generator is equipped with a low-oil sensor and will not start without a sufficient amount of oil.
To check oil level (before every subsequent start):
1. Place the generator on a level surface. Make sure the engine is off before adding or checking oil.
2. Open the oil access cover. Remove and wipe the dipstick with a clean rag.
3. Insert the dipstick into the oil fill without screwing it in. Remove the dipstick to check the oil mark (Fig. 4).
If the oil mark covers less than one half of the dipstick, slowly add oil until the oil mark reaches to the top of the
dipstick (or when you can see the oil coming halfway up the oil fill threads).
4. Wipe clean any oil leaks and firmly tighten the dipstick. Reinstall the oil access cover.
OIL LEVEL SHUTDOWN
To protect the unit from damage, the generator is equipped
with a low-oil-pressure shutoff that will automatically stop
the engine when the oil level is too low. The yellow low oil
indication light (Fig. 5) will turn ON to remind you that the
engine oil level is low and need to be refilled.
The oil level of the engine should be checked before each
start to ensure that the engine crankcase contains suf-
ficient lubricant.
TIP: Your WEN generator is compatible with the WEN
55201 Magnetic Oil Dipstick (not included), available
for purchase at wenproducts.com. The dipstick’s in-
dustrial-strength magnetic tip will collect metal shav-
ings from your generator’s oil compartment to help
preserve the engine and extend your generator’s lifes-
pan.
Lower Limit
Upper Limit
Fig. 4
Fig. 5
14
Low Oil Indicator

GENERATOR PREPARATION
WARNING! RISK OF EXPLOSION. HIGHLY FLAMMABLE: This generator may emit highly flammable and
explosive gasoline vapors, which can cause severe burns or even death, if ignited. A nearby open flame can lead
to explosion even if not directly in contact with gasoline.
• Do not operate near open flame, heat, or any other ignition source. Do not smoke near the generator.
• Always operate on a firm, level surface.
• Always turn generator off before refueling. Allow generator to cool for at least 2 minutes before removing
fuel cap. Loosen cap slowly to relieve pressure in tank.
• Do not overfill fuel tank. Gasoline may expand during operation. Do not fill to the top of the tank. Allow for
expansion. Always check for spilled fuel before operating.
• If fuel spills, move the generator at least 30 feet away from the spill and wipe clean any spilled fuel before
starting the engine.
• Empty fuel tank before storing or transporting the generator.
STEP 2 - ADD / CHECK FUEL
Use ONLY fresh (within 30 days from purchase), lead-free gasoline with a minimum of 87 octane rating. The genera-
tor performs best with ethanol-free gasoline. DO NOT use gasoline with over 10% ethanol. The capacity of the fuel
tank is 2.2 US gallons (8.50 L). Do not mix oil with gasoline.
To add gasoline:
1. Make sure the generator is shut OFF and on a level sur-
face. Unscrew the fuel cap (Fig. 6) and set it aside. The fuel
cap may be tight and hard to unscrew.
2. Slowly add unleaded gasoline to the fuel tank. Be careful
not to overfill.
NOTE: Do not fill the fuel tank to the very top. If you do so,
gasoline will expand and spill during use, even with the fuel
cap in place.
3. Reinstall fuel cap and wipe clean any spilled gasoline with
a dry cloth.
To check fuel level:
During operation, the fuel level will be displayed by the in-
dicator lights on the right side of the multi-meter. If the fuel
level is low, refill the fuel tank before starting your generator
for the next time.
IMPORTANT:
• Avoid getting dirt or water into the fuel tank.
• Keep gasoline away from sparks, open flames,
pilot lights, heat, and other sources of ignition.
• Gasoline can age in the tank and make starting
difficult. Never store the generator for more
than 2 months with fuel in the tank.
• Never use an oil/gasoline mixture.
• Never use old gasoline.
Fig. 6
Fuel Cap
15

GENERATOR PREPARATION
STEP 5 - GROUND THE GENERATOR
To reduce the risk of electric shock and to maximize safety, the genera-
tor should be properly grounded.
Ground the generator by tightening the grounding nut (Fig. 7) on the
front control panel against a grounding wire. A generally acceptable
grounding wire is a No. 12 AWG (American Wire Gauge) stranded cop-
per wire.
This grounding wire should be connected at the other end to a copper,
brass, or steel grounding rod that is driven into the earth. Wire and
grounding rods are not included with the generator.
NOTE: Grounding codes can vary by location. Contact a local electri-
cian to check the area codes.
WARNING! Failure to properly ground the generator increases your risk of electric shock.
HIGH ALTITUDE OPERATION ABOVE 3000 FEET
The fuel system on this generator may be affected by operation at high altitudes. Proper operation can be ensured
by installing an altitude kit at altitudes higher than 3000 feet above sea level. At elevations above 8000 feet, the en-
gine may experience a decrease in performance, even with the proper altitude kit. Operating this generator without
said kit may increase the engine’s emissions and decrease both fuel economy and performance.
You can order the kit at wenproducts.com by searching part 56450i-HA. There are two kits - one for altitudes be-
tween 3000 and 6000 feet (56450i-HA36), and the other for altitudes from 6000 to 8000 feet (56450i-HA68). This
kit should be installed by a qualified mechanic. Refer to the instructions included with your altitude kit for more
information about installation
WARNING! To prevent serious injury from fire, follow the kit installation procedures in a well-ventilated
area away from ignition sources. If the engine is hot from use, shut the engine off and wait for it to cool before
proceeding. Do not smoke near the generator. Warranty will be void if adjustments are not made for high altitude
use.
CAUTION: Engines with the high-altitude kit installed operated at lower altitudes could cause severe engine dam-
age and affect emissions compliance. Be sure to uninstall the high altitude kit when operating at altitudes below
3000 feet.
After completing the above preparation, the generator is ready to be started.
Fig. 7
Grounding Nut
16

CAUTION!
Disconnect all electrical loads from the generator before attempting to start.
Before starting the generator, make sure you have read and performed the steps in the “Generator Preparation”
section of this manual. If you are unsure about how to perform any of the steps in this manual please call 1-(800)
232-1195 M-F 8-5 CST for customer service.
To maximize safety, ALWAYS ground the generator before using it. See section “Ground the Generator”.
Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. GFCIs
are available in-line with some extension cords.
STARTING YOUR GENERATOR
DANGER! CARBON MONOXIDE
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide (CO). This
is a poison gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even
if you cannot smell the exhaust, you could be breathing CO.
NEVER use a generator inside homes, garages, crawl spaces, or other partially enclosed areas. Deadly levels
of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply
enough fresh air. ONLY use a generator outside and far away from windows, doors, and vents. These openings
can pull in generator exhaust.
Even if you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-
backup CO alarm in the home. If you start to feel sick, dizzy, or weak after the generator has been running, move
to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.
WARNING! The exhaust from this product contains chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING! Do not operate generator near open flame or flammable materials This generator may emit
highly flammable and explosive gasoline vapors, which can cause severe burns or even death if ignited. A
nearby open flame can lead to explosion even if it isn’t directly in contact with gasoline. Do not smoke near the
generator.
WARNING! This generator produces powerful voltage, which can result in electrocution.
WARNING! Do not use in rainy or wet conditions. Do not touch bare wires or receptacles (outlets). Do not
allow children or non-qualified persons to operate.
WARNING! Generator should only be connected to electrical devices, either directly or with an extension
cord. NEVER connect to a building electrical system without a qualified electrician and connected to a transfer
switch as a separately derived system. Such connections must comply with local electrical laws and codes.
Failure to comply can create a back-feed, which may result in serious injury or death to utility workers.
Follow the instructions on the next page to start your generator.
17

STARTING YOUR GENERATOR
BEFORE STARTING THE GENERATOR
1. Verify that generator is outside on a dry, level surface with at least two feet of clearance on all sides.
2. To maximize safety, check that the generator is properly grounded (see “Ground the Generator”).
3. Check there is sufficient level of oil in the crankcase. Add oil if necessary (see “Add / check Oil”).
4. Make sure there is sufficient level of gasoline in the fuel tank. Add fuel if necessary (see “Add / check Fuel”).
5. Make sure all electrical devices are unplugged from the generator during ignition. Otherwise it will be difficult for
the engine to start.
STARTING THE GENERATOR
1. Turn the ECO-MODE (Fig. 8) switch to “OFF” during starting.
2. Turn the 3-in-1 dial switch (Fig. 9) to the “CHOKE” position.
3. Pull the recoil starter to start the engine.
4. Turn the 3-in-1 dial switch (Fig. 9) to the "RUN" position.
5. Allow the generator to run for several minutes before attempt-
ing to connect any electrical devices. This allows the generator to
stabilize its speed and temperature.
6. Connect electrical devices.
Fig. 8
Fig. 9
Fig. 10
18

USING YOUR GENERATOR
CALCULATING THE WATTAGE OF YOUR DEVICE(S)
Connect electrical devices running on AC current according to their wattage requirements. Calculate the total run-
ning wattage and starting wattage of the device(s) you wish to connect, and MAKE SURE that they are within the
capacity of your generator and the capacity of each individual outlet.
Generator
Wattage
Capacity
GENERATOR RUNNING (RATED) WATTS GENERATOR STARTING (SURGE) WATTS
3500W 4500W
What this means:
The generator can produce a maximum of
3500W on a continuous basis to supply on-
going power to your electronic devices.
NOTE: Also check the rated amperage for
each outlet and make sure not to overload
the individual outlets.
What this means:
Some devices such as box fans require short
bursts of extra power in addition to the rated
wattage listed by the device to start their mo-
tors.
The generator can produce a maximum watt-
age of 4500W for a short period of time
(seconds) to cover the extra starting power
required by your electronic devices.
Electronic
Device
Wattage
Calculation
Find the wattage information of each device you plan to connect. The information should be
listed on the device or in its instruction manual, or you may refer to page 20, Table 2.
The wattage can be calculated using this equation: Watts = Volts x Amperes
To calculate the total running watts of your
devices:
+Add up the running wattages of all the
device(s) you plan to connect.
=The total running (rated) wattage.
This wattage should NOT exceed the run-
ning wattage of 3500W.
It is recommended to maintain a load at or
below 3150W (90% of the rated output) to
ensure steady voltage output and to prolong
the generator’s lifespan.
To calculate the total starting watts of your
devices:
+Add up the total running wattage of all the
device(s) you plan to connect.
+Add the single highest ADDITIONAL start-
ing wattage out of the device(s) you plan to
connect.
=The total starting (surge) wattage.
This wattage should NOT exceed the starting
wattage of 4500W.
If any of either of the total calculated running watts or starting watts is higher than the capac-
ity of your generator, adjust the load until both wattage requirements are met. Otherwise you
will overload the generator, and cause damage to the engine and your electrical device(s).
Table 1 - How to Calculated Wattages
19

USING YOUR GENERATOR
CALCULATING THE WATTAGE OF YOUR DEVICE(S) - CONTINUED
The chart below serves as a reference for the estimated wattage requirements of common electrical devices. How-
ever, do not solely rely on this chart - all electronics and appliances are built differently. Always check the wattage
listed on the electrical device before consulting this chart.
Tool or Appliance Rated (Running) Watts Surge (Starting) Watts
Electric Water Heater (40 Gal) 4000 0
Hot Plate 2500 0
Saw - Radial Arm 2000 2000
Electric Stove (Each Element) 1500-2800 0
Saw - Circular 1500 1500
Air Compressor (1 HP) 1500 3000
Window Air Conditioner 1200 1800
Saw - Miter 1200 1200
Microwave 1000 0
Well Water Pump 1000 1000
Sump Pump 800 1200
Refrigerator Freezer 800 1200
Furnace Blower 800 1300
Computer 800 0
Electric Drill 600 900
Television 500 0
Deep Freezer 500 500
Garage Door Opener 480 0
Stereo 400 0
Box Fan 300 600
Clock Radio 300 0
Security System 180 0
Dvd Player / VCR 100 0
Common Light Bulb 75 0
Table 2 - Estimated Wattages of Common Electrical Appliances
NOTE: Become familiar with the functions and capacity of each component on the control panel before con-
necting electrical devices. See page 23 for more information about the components of the control panel. Do not
overload generator or individual panel receptacles. Do not connect 50Hz or 3-phase loads to the generator.
20
Table of contents
Other Wen Portable Generator manuals
Popular Portable Generator manuals by other brands

Champion Global Power Equipment
Champion Global Power Equipment 201064 quick start guide

HISPANUS
HISPANUS FUERTES 3000 user manual

Chamberlain
Chamberlain LiftMaster Professional 475M owner's manual

Giga-tronics
Giga-tronics 2502B Operation manual

Tektronix
Tektronix AWG510 Service manual

Briggs & Stratton
Briggs & Stratton Portable Generator Operator's manual