LED Driver Controller LDC-01
—For DCCP series LED driver
Thank you for selecting the product. LDC-01(LED Driver Controller) is an optional accessory for DCCP series LED DC
driver. It can realize max. 4 -timer working. For each timer, 0~9 working hours and 0~100% output power is adjustable.
The output power can also be adjusted automatically with changes of battery voltage and temperature. Read this manual
carefully and thoroughly so as to preferably install and use the product. Under normal service conditions, the warranty
period of the product is two (2) years free of charge, starting from the sales date.
Introductions:
As shown in above picture:
Input terminals: connect controller or other DC power supply.
Output terminals: connect DCCP series LED driver. PWM frequency is 200Hz.
Button: Set the working hours and power percentage.
Display bar: Display the timer and power percentage.
Temperature sensor: fit to the heat sink of LED source.
Functions:
Operations:
1. Under non-setting state, press the button lightly, LED indicators are lighted circularly each time,
2. Press the button for more than 5 seconds till the LED indicator flashing. Release it at this moment. Then press the
button to choose the desired number.
3. Under the setting state, if the desired number appears, stop pressing the button. When the LED indicator stops
flashing, the setting is successfully.
4. If there is no any button pressing within 15 seconds, the LED indicator and digital tube will be turned off
automatically for power saving.
Display bar
Output
terminals
Input
terminals
Button
Temperature sensor
Solar Charge Controller
+
-
Load
~ 2 ~
Timer section
Working mode
Indicator
Working mode
Timer-1
‘0’:non-working
‘1~9’:1-9 hours working
Power%-1
‘0’:no output;
‘1~9’:10%~90% power
‘–’:100% power
Timer-2
‘0’:non-working
‘1~9’:1-9 hours working
Power%-2
‘0’:no output;
‘1~9’:10%~90% power
‘–’:100% power
Timer-3
‘0’:non-working
‘1~9’:1-9 hours working
Power%-3
‘0’:no output;
‘1~9’:10%~90% power
‘–’:100% power
Timer-4
‘0’:non-working
‘1~9’:1-9 hours working
Power%-4
‘0’:no output;
‘1~9’:10%~90% power
‘–’:100% power
Volt.adj.
‘3~9’:30%~90% power, Limited power percentage of voltage control;
‘–’:100% power, no limitation.
Temp.adj.
‘3~9’:30%~90% power, Limited power percentage of temperature control;
‘–’:100% power, no limitation.
Notes:
1. Limited power percentage of voltage control:
When battery voltage changes, the actual operating power is limited, which is a linear increase or decrease. It operates as
per the following formula:
Actual operating power% = [(Battery voltage-11.1V)/(12.0-11.1V)]*(setting power% of current timer section - limited
power%)+limited power %.
Notes: When it is powered for the first time, the system identifies the voltage<18V as 12V system, and ≥18V as 24V
system. The above formula is applicable for 12V system. If it is 24V system, 11.1v is changed into 22.2V and 12.0V into
24.0V in the formula. When the battery voltage is lower than 11.1V or 22.2V, the formula is not applicable and the actual
power is operated as per the limited power. And when the battery voltage is higher than 12V or 24V, the actual power is
operated as per the setting power of current timer.
2. Limited power percentage of temperature control:
The control theory for temperature change is the same as voltage change, with the formula changed into the following:
Actual operating power% = [(current temperature-75℃)/(85℃-75℃)]*(setting power% of current timer section - limited
power%)+limited power %.
Notes: The effective temperature range is 75℃~85℃. When it is lower than 75℃, the actual power is operated as per the
setting power of current timer section. And when it is higher than 85℃, it is operated as per the limited power.
3. If the limited power percentage of voltage control or temperature control is more than current timer section, or there
is no power percentage limitation of voltage and temperature, it operates as per the power of the current timer.
4. When percentage limitations of voltage and temperature work at the same time, the actual power operates as per the
min. power calculated with the above formulas.
5. There is a period of 2-20 seconds for power adjustment each time, so it is not realized at once. The frequency of
PWM is 200Hz. Parameters:
Item
Parameters
Input voltage range
8 ~ 32VDC
Max. input current
9A
Ambient temperature
-40℃~ +65℃
Storage temperature
-40℃~ +85℃
Humidity
0 ~ 95% N.C.
Enclosure
IP30
Altitude
≤5000m
Overall
78mm x 49mm x 21mm
Mounting
69mm (vertical)
Mounting hole
Φ5 (R2.46)
Terminal
2.5mm2
Net weight
38g
Version Number:V1.1

Other WESTECH Controllers manuals

WESTECH LandStar LS1024RP User manual

WESTECH

WESTECH LandStar LS1024RP User manual

WESTECH SeaStar SS1024 User manual

WESTECH

WESTECH SeaStar SS1024 User manual

WESTECH LandStar LS1024R User manual

WESTECH

WESTECH LandStar LS1024R User manual

Popular Controllers manuals by other brands

PAW FC3.10 Installation and operation instructions

PAW

PAW FC3.10 Installation and operation instructions

ICP ICP5085BR specification

ICP

ICP ICP5085BR specification

Festo CMMP Series manual

Festo

Festo CMMP Series manual

Eltako FSR61NP-230V manual

Eltako

Eltako FSR61NP-230V manual

Elan S128P installation manual

Elan

Elan S128P installation manual

Controlli MVE2XX Mounting instructions

Controlli

Controlli MVE2XX Mounting instructions

Bosch Plena LBB1990/00 Use manual

Bosch

Bosch Plena LBB1990/00 Use manual

Steren MODLED-010 instruction manual

Steren

Steren MODLED-010 instruction manual

AMX AutoPatch quick start guide

AMX

AMX AutoPatch quick start guide

vacuubrand CVC 3000 Instructions for use

vacuubrand

vacuubrand CVC 3000 Instructions for use

AMETEK/PRESTOLITE POWER AC500 owner's manual

AMETEK/PRESTOLITE POWER

AMETEK/PRESTOLITE POWER AC500 owner's manual

Ltech LT-3900 quick start guide

Ltech

Ltech LT-3900 quick start guide

Fisher 670F instruction manual

Fisher

Fisher 670F instruction manual

Nectar Sun PVHC-2.01 user manual

Nectar

Nectar Sun PVHC-2.01 user manual

PI V-273 user manual

PI

PI V-273 user manual

Faulhaber MCDC 3002/03/06 RS/CF/CO Series Technical manual

Faulhaber

Faulhaber MCDC 3002/03/06 RS/CF/CO Series Technical manual

SMC Networks LEC-W2 installation manual

SMC Networks

SMC Networks LEC-W2 installation manual

KMC Controls MEP-46 Q Series quick start guide

KMC Controls

KMC Controls MEP-46 Q Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.