Western IDRA ISKV-12 C6 Technical specifications

USE AND
INSTALLATION
MANUAL IDRA
Heat pump water condenser air
conditioning system
MULTI split
ISKOV2-18 C6/H6
ISKOV3-24 C6/H6
ISKOV4-28 C6/H6
MONO split
ISKV-12 C6/H6
ISKV-18 C6/H6
ISKV-24 C6/H6
ISKUOV-36 CT6/HT6
Vers. 1.1

DECLARATION OF CONFORMITY
Is in compliance with the follow ECC direcrives, latest modication included, and the relevant nationale granting
regulations in force:
2004/108/CE
2006/95/CE
2003/108/CE
2011/65/CE
2012/2016/CE
ISKOV2-18 C6/H6
ISKOV3-24 C6/H6
ISKOV4-28 C6/H6
ISKV-12 C6/H6
ISKV-18 C6/H6
ISKV-24 C6/H6
ISKUOV-36 CT6/HT6
Description
CONDENSING UNIT DC INVERTER WATER TO AIR
Model

1. GENERAL INFORMATION
2. DESCRIPTION UNIT IDRA
3. INSTALLATION
4. INSTALLATION INDOOR UNIT
5. CHECKS AFTER INSTALLATION
6. MAIN FUNCTION IDRA
7. SELF-DIAGNOSIS
8. MAINTENANCE IDRA UNIT
pagechapter
04
06
07
14
17
18
19
22
INDEX

INSTALLATION MANUAL IDRA
4
1.1 SYMBOLS
1.2 PERMITTED USE
In this publication and/or on this unit the following symbols have been used:
These machines have been created to heat or cool the air.
Use of the units for applications other than those specifically
authorised by the manufacturer is considered inappropriate
and, therefore, not allowed. The company declines all
contractual and extra-contractual responsibility for damage
caused to people, animals and objects resulting from errors
in installation, calibration and maintenance, improper use,
or from the partial or superficial reading of the information
contained in this manual. In addition, keeping in mind the
continued product improvement, T.P.I. reserves the right
to change the information found in this manual at any
moment without notice, and declines all responsibility for
any inaccuracies in this manual, if due to errors in printing
or copying.
Carefully read this booklet; all operations must be carried
out by expert and qualified personnel who are familiar with
the related laws in force in the different countries concerned.
USER: In this publication and/or on this
unit the following symbols have been used:
INSTALLER: Information, paragraph or
chapter of manual that concerns the
installer.
TECHNICAL ASSISTANCE CENTRE:
Information, paragraph, chapter of the
manual that concerns the technical
assistance centre.
IMPORTANT: Calls attention to technical
information or practical advice which
makes using the unit efficient and
economical.
COMPULSORY: Calls attention to
mandatory actions in order to obtain
correct machine
1. GENERAL INFORMATION
U
INS
CAT
U INS CAT
The guarantee is invalidated if they do not meet the
above mentioned directions.
The documentation supplied with the unit must be delivered
to the end customer (user) who should keep it carefully for
future maintenance or service.
Upon delivery of the goods by the carrier, check the
integrity of the packaging is that the units. Should you find
any damage or lack of components, indicate this on the
delivery note to the unit’s receipt: please make an all-party
control, in order to verify that the transport did not cause
damage, the damage may be present must be communicated
to the carrier, adding the clause reserves on the transport
document, specifying the type of damage, also inform, by fax
or registered mail within 8 days from the date of receipt of
goods, a formal complaint to the company.
WARNING: Calls attention to actions that,
if not correctly performed, may cause
serious injury.
PROHIBITION: Calls attention to actions
that impose a ban.
VOLTAGE WARNING: Calls attention to
actions that, if not carried out correctly, can
cause serious injury or death to exposed
persons.
DANGER HIGH TEMPERATURES: Calls
attention to actions that, if not correctly
performed, may cause serious personal
injury caused by the high temperature of
the components.

INSTALLATION MANUAL IDRA 5
1.3 OSSERVAZIONI
1.4 FUNDAMENTAL SAFETY RULES
Conserve the manual in a dry place, to avoid deterioration,
for at least 10 years for future reference. Completely and
carefully read all the information contained in this manual. Pay
particular attention to the any rules accompanied by the words
«DANGER», «PROHIBITED» «MANDATORY» in that, if not
followed, may cause damage to the machine and/or people
and objects. For potential problems not considered in this
manual, promptly consult T.P.I.’S service assistance centre.
The manufacturer declines all responsibility for damage due
to improper machine use or the partial or superficial reading
of the information contained in this manual.
Recall that the use of products using electricity and
water, involves the observance of some fundamental
safety rules such as:
The use by children and unassisted disabled persons.
Do not touch the appliance when barefoot or with wet or
damp parts of the body.
It does not carry out cleaning operations without first
disconnecting the electric power supply by moving the
main system switch to “off.”
It is forbidden to modify the safety or adjustment devices
without authorization and instructions from the manufacturer.
The machine must be installed in such a way that makes
maintenance and/or repair operations possible.
In any case, the guarantee does not cover, costs due to
ladders, scaffolding or other systems of elevation which may
be necessary for carrying out repairs under guarantee.
The manufacturer does not issue drawings or specifications
relative to connection systems.
Any deviation from the requirements contained in the following
manual must be validated in writing by the manufacturer’s
technical assistance department
Do not pull, detach or twist the electrical cables coming
from, even when disconnected from the power network.
Do not open the doors of access to internal components, if it
is not switched off the system using the main switch.
You do not climb on the appliance with walking, sitting and /
or rest any type of object.
Do not spray or pour water directly on the unit.
You not dispose of, abandon or leave within reach of children
packaging materials (cardboard, staples, plastic bags, etc.)
As it can be potentially dangerous.
Respect safety distances between the unit and
other equipment or structures to ensure sufficient
drive access space for maintenance and / or service
as described in this handbook (see chapter Technical
spaces).
Power unit: must be done with electric cables of
adequate section for the power of the unit and the
power supply voltage values must match those
indicated on the respective machines; All units must
be earthed in compliance with current legislation in
the different countries.
hydraulic coupling must be performed as
instructed to ensure proper operating condition. If
during the winter period the unit is not in operation it
is necessary to empty the water circuit.
Handle the unit with care avoiding to turn it over and
overlay parcels that could damage it.
Tampering, removal, deterioration of identification
plates, makes difficult any installation,
maintenance and ordering spare parts.
1.5 RECEIPT OF THE PRODUCT AND HANDLING
This equipment is supplied on a wooden pallet protected by
cardboard packaging. A kit is also provided:
- Manual Installation, use and maintenance of comprehensive
warranty and the EC declaration
- Anti-vibration feet, water filter, gas fittings for indoor unit (in
models where necessary).
- Documentation ventilating unit (inside their packaging).
- Connection diagram (adhesive label on the inside of the
inspection panel).
This manual suits for next models
13
Table of contents
Other Western Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual