Wetco BNT165 Series User manual

Table of Contents
Introduction………………………………………………………………………………………………...1
Main Functions…………………………………………………………………………………………….1
Specifications……………………………………………………………...………………………………2
Programming………………………………………………………………………………………………3
1.Key Definition………………………………………...…………………………………………..3
2.Setting Methods………………………………………………………………………………….3
3.Inquiry Function………………………………………………………………………………….4
4.System Initialization……………………………………………………………………………..4
5.Menu Diagram at Different Regeneration Modes……………………………………………5
6.Default Settings………………………………………………………………………………….7
Manual Regeneration…………………………………………………………………………………….7
Water Hardness Adjustment (Optional for Softener Valve)……………………………………..……8
Optional Parts……………………………………………………………………………………………..8
1. Inlet/Outlet Screw Standards……………………………………………………………………..8
2. Inlet/Outlet Screw Adaptor (Optional)……………………………………………………………8
3. Inlet/Outlet Connections Types…………………………………………………………..……….9
4. Drain Line Flow Controls (DLFC) and Injector…………………………………………………10
5. Bypass Assembly…………………………………………………………………..……………..12
Valve Powerhead Assembly………………………………………………………………………….13
Valve Body Assembly……………………………………………………………………………………16
Bypass Assembly…………………………………………………………………………………….….19
General Valve Installation……………………………………………………………………………….21
Trouble Shooting……………………………………………………………………………………...…22

BNT165/BNT265 Series Valve Operation Manual
- 1 -
Introduction
This valve is controlled with simple, user-friendly electronics displayed on a LCD screen. The
main page displays the current time. In addition, the main page also shows key valve information
including: regeneration mode, volume remaining (meter mode), regeneration days remaining
(timer mode).
BNT165 Series Outline BNT265 Series Outline
Bnt165 Key Pad Bnt265 Key Pad
Main Functions
●Valve Operation Mode:
1. SOFTENER: Standard water softener operation.
2. FILTER: Automatic backwashing filters such as Multi-Media Depth or
Carbon Filter.
●Regeneration Mode:
1. Calendar Clock 2. Meter Immediate 3. Meter Delayed
4. Meter Override
●Water Hardness can be adjusted:

BNT165/BNT265 Series Valve Operation Manual
- 2 -
User can adjust the mixing valve to get proper water hardness (optional for
softener valve).
●Display Format:
Metric format and US format are available to meet the different customers’
requirements.
●Three factory setting defaults are available:
1. Large capacity mode (ab. L.CAPA.)………fit the large size tank;
2. Medium capacity mode (ab. M.CAPA.)…...fit the medium size tank;
3. Small capacity mode (ab. S.CAPA.)………fit the small size tank.
●Auto-locking:
All keys will be locked after 3 minutes during the stand-by status, press and
hold “MENU” key for 3 seconds to unlock.
Specifications
●Hydrostatic Test Pressure ………....350 psi (24.15 bar)
●Working Pressure…………………...20~125 psi (1.38~8.62 bar)
●Working Temperature……………….1℃~39℃
●Riser Pipe Diameter Required……..1.050 inch (26.7mm)
●Electrical Adapter……………………Input:AC110V/AC240V,50Hz/60Hz; Output:AC12V
●Pressure Tank Thread………..……..2.5″NPSM
●Inlet/Outlet Connector……………....1″, 3/4″, 1/2″ (PPR, PPO, Brass)
BNT165 Series Dimensional Drawing (unit: inch, mm in brackets)

BNT165/BNT265 Series Valve Operation Manual
- 3 -
BNT265 Series Dimensional Drawing (unit: inch, mm in brackets)
Programming
1.Key Definition:
Menu key “ ”:
●Press this key to enter or exit the menu.
●Press and hold this key for 3 seconds to unlock when the screen was locked at
standby status.
Set/Regen. key “ ”:
●Press this key to select a program or to save the settings.
●Press and hold the key for 3 seconds to enter the manual regeneration interface
at standby status.
Up and Down key “ ”, “ ”:
●Press the key to increase or decrease the value of the settings.
●Press the key to enter the previous or the next menu.
2.Setting Methods:
●Press the key “ ” to enter the menu.
●Press the key “ ” or “ ” to select a parameter.
●Press the key “ ” to make the parameters flashing.
●Press the key “ ” or “ ” to change the value.
●Press the key “ ” to save the setting.
●Press the key “ ” or “ ” to select another parameter.
●Follow the above steps to change another parameter.
●Press the key “ ” to exit settings.
You can only change the flashing parameters.
Program will be back to standby status if any key was not operated in 1 minute.
Without being operated in 3 minutes, the keys will be locked.

BNT165/BNT265 Series Valve Operation Manual
- 4 -
3.Inquiry Function:
Press the key “ ”and “ ” simultaneously at the standby status, the screen will
display different regeneration information at different regeneration mode.
●Calendar Clock:
The first raw shows the days remaining of one regeneration cycle.
The second raw shows regeneration time.
D-07
02:00 AM
●Meter Immediate, Meter Delayed, Meter Override:
The first raw is the volume remaining of one regeneration cycle in meter. “G”
refers to Gallon
The second raw is total usage.
1300G
0000800G
4.System Initialization:
When power is first supplied, the valve may take about two minutes to initialize,
and the valve will show:
WAITING
PLEASE
Any key will be overridden at this time. When the valve reaches the service
position, it will display:
Regeneration Mode: Calendar Clock
09:00 AM
CC-07
Current Time
Regeneration Days Remaining
Calendar Clock
Regeneration Mode
Regeneration Mode: Meter Immediate
09:00 AM
MI-0900G
Current Time
Volume Remaining
Meter Immediate
Regeneration Mode Gallon
Regeneration Mode: Meter Delayed
09:00 AM
MD-0900G
Current Time
Gallon
Meter Delayed
Regeneration Mode
Volume Remaining

BNT165/BNT265 Series Valve Operation Manual
- 5 -
Regeneration Mode: Meter Override
09:00 AM
MO-0900G
Current Time
Gallon
Meter Override
Regeneration Mode
Volume Remaining
5. Menu Diagram at Different Regeneration Modes:
There is no “BRINE DURATION” and “REFILL DURATION”in filter valve.
METER
OVERRIDE
TIME
REG. TIME
REG. DAYS
REG. CAP.
BACK WASH
BRINE
RINSE
REFILL
LOAD
DEFAULT
CURRENT TIME
REGEN. TIME
DEFAULT 02:00
REGEN. DURATION
REGEN. CAPACITY
BACKWASH DURATION
BRINE&DRAW
DURATION
RINSE DURATION
REFILL DURATION
LOAD DEFAULT DATA
CALENDAR
CLOCK
TIME
REG. TIME
REG. DAYS
BACK WASH
BRINE
RINSE
REFILL
LOAD
DEFAULT
METER
IMMEDIATE
TIME
REG. CAP.
BACK WASH
BRINE
RINSE
REFILL
LOAD
DEFAULT
METER
DELAYED
TIME
REG. TIME
REG. CAP.
BACK WASH
BRINE
RINSE
REFILL
LOAD
DEFAULT
REGEN. MODE
REGIONAL
METRIC REGIONAL
US
Press MENU Key
L CAPA. M CAPA. S CAPA.
END
L CAPA.
FOR LARGER TANK
M CAPA.
For MIDDLE TANK
S CAPA.
FOR SMALLER TANK

BNT165/BNT265 Series Valve Operation Manual
- 6 -
PARAMETER
OPTIONS
DESCRIPTION
2
REGIONAL
METRIC
This option controls which unit format should be displayed in
the valve display.
US
3
(REGENERATION
MODE)
CALENDAR
CLOCK
The unit will initiate a regeneration at the next pre-set
regeneration time based on the interval of regeneration days.
METER
IMMEDIATE
The unit will initiate a regeneration immediately after the
volume remaining reaches zero.
METER
DELAYED
This is the most common setting. When the volume
remaining reaches zero, the system will initiate a
regeneration at the next pre-set regeneration time.
METER
OVERRIDE
When the volume remaining reaches zero, the system will
initiate a regeneration at the next pre-set regeneration time. If
the days between regeneration are reached before the
volume remaining reaches zero, the system will override the
meter setting and initiate a regeneration.
4
MO-DA-YE
(MONTH-DATE-YE
AR)
This setting is the current date. The date is used to track the
last time the system regenerated.
5
TIME
This setting is the current time of day.
6
REG. TIME
(REGENERATION
TIME)
This setting controls the time when a regeneration cycle will
start.
7
REG. DAYS
(REGENERATION
DAYS)
This value is the interval (days) between regenerations. It is
used to determine how many days between regenerations
9
REG. CAP.
This value is the total capacity between regenerations. It is
used to determine how many gallons can be used between
regenerations
10
BACKWASH
This setting controls the length of time for the unit to clean the
bed by reversing the flow of water upwards through the bed
and out to the drain.
11
BRINE
This setting controls the length of time for the unit to draw
regeneration (brine for softeners) from the brine tank and
slowly rinse it from the top to bottom of the media tank.
12
RINSE
This setting controls the length of time to give the tank a final
rinse from the top to the bottom in order to remove any last
traces of the regeneration from the tank.
13
REFILL
This setting controls the length of time which the brine valve
will open to refill the brine tank with water in order to produce
the regeneration solution for the next regeneration cycle. The
water accurately measured through the valves brine line flow
control to make a precise quantity of regeneration solution.
14
LOAD DEFAULT
This setting allows the current settings to be erased and
changed back to the default settings.

BNT165/BNT265 Series Valve Operation Manual
- 7 -
6.Default Settings.
Three default settings are available:
●Large capacity mode (L-CAPA.)…….….fit the larger size tank;
●Medium capacity mode (M-CAPA.)…....fit the medium size tank;
●Small capacity mode (S-CAPA.)………fit the smaller size tank.
Default value as follows:
Large
Capacity
Medium
Capacity
Small
Capacity
BACKWASH DURATION (minute)
10
10
10
BRINE DURATION (minute)
60
60
60
RINSE DURATION (minute)
10
10
10
REFILL DURATION (minute)
4.3
2.9
2.1
REGEN. DAYS (day)
8
5
3
REGEN. CAPACITY (Gallon)
FOR METER VALVE
1200
800
525
Manual Regeneration
Press and hold the key “ ” for 3 seconds to unlock screen.
In stand-by position, you can press and hold the key ‘■’for 5 seconds to into the manual
regeneration interface:
MAN.REG.
DELAY
MAN.REG.
IMMEDIAT
(1) If you choose ‘DELAY’ and press key ‘ ’ to exit, the valve will regeneration in next
REGEN. TIME (default is 02:00);
Note: The regeneration mode "METER IMMEDIATE" has no 'DELAY' choice here.
(2) If you choose ‘IMMEDIAT’ and press key ‘ ’ to exit, the valve will regeneration
immediately.
When regeneration started, the screen will display:
BACKWASH
--------
“BACKWASH”starts flashing. When the valve reaches “BACKWASH”position,
“BACKWASH”stops flashing. Dash line (the second raw) will be shortened on the way of
regeneration. Pressing any key will automatically advance the valve to the next cycle position:
BRINE, Screen will display:
BRINE
--------
Valve will be advanced to the rest of the regeneration (RINSE and REFILL) just like the
above steps.

BNT165/BNT265 Series Valve Operation Manual
- 8 -
Water Hardness Adjustment (Optional for Softener Valve)
Users can adjust the Water Hardness Adjustment Nut to get their desired water
hardness (optional for softener valve)
Operation methods:
Rotate the Water Hardness Adjustment Nut in a clockwise direction. The bigger
rotation angle, the higher water hardness.
Optional Parts
The following optional parts are used for both Bnt165 and Bnt265.
1.Inlet/Outlet Screw Standards:
Table I
BSP Screw
NPT Screw
Straight
900 Elbow
Straight
900 Elbow
1/2"、3/4"、1"
1/2"、3/4"、1"
3/4",1"
3/4"
2.Inlet/Outlet Screw Adaptor (Optional):
No.
Name
No.
Name
1
PPR Adaptor 1'
10
Nylon tri-pieces
4F×2F×4M
2
PPR Adaptor 3/4
11
Adaptor Ⅲ
Connect Screw NPT1M
3
PPR Adaptor 1/2
12
Adaptor Ⅲ
Connect Screw NPT6M
4
Adaptor (American standard 1'
black)
13
Adaptor Ⅲ
Universal plug
5
Adaptor (American standard 6")
14
Adaptor Ⅲ
Connect screw 4F
6
Adaptor (American standard 4")
15
Adaptor Ⅲ

BNT165/BNT265 Series Valve Operation Manual
- 9 -
Elbow screw 6M
7
Adaptor Ⅲconnect screw 1M
16
Adaptor Ⅲ
Elbow screw 4M
8
Adaptor Ⅲconnect screw 6M
17
Adaptor Ⅲ
Elbow screw NPT6M
9
Adaptor Ⅲconnect screw 4M
18
Adaptor Ⅲ
Elbow screw 1M
3.Inlet/Outlet Connections Types:

BNT165/BNT265 Series Valve Operation Manual
- 10 -
4.Drain line Flow Controls (DLFC) and Injector:
Replacing Injector and DLFC according to the following picture.
For reference only:Different Size injector & DLFC is available for different Softener tanks as
follows
Item
Tank
Size
Water Softener
Injector
DLFC
BLFC
Serial
number
Color
Spec
Serial
number
Spec
Serial
number
Spec
1
0722
30040079
30040080
Gray
000#
05056185
1#
1.5GPM
05056206
05056076
0.2 GPM
0.3 GPM
2
0735
30040079
30040080
Gray
000#
05056185
1#
1.5GPM
05056206
05056076
0.2 GPM
0.3 GPM
3
0815
30040079
30040080
Gray
000#
05056186
2#
2.0GPM
05056206
05056076
0.2 GPM
0.3 GPM
4
0817
30040079
30040080
Gray
000#
05056186
2#
2.0GPM
05056206
05056076
0.2 GPM
0.3 GPM
5
0835
30040081
30040082
Purple
00#
05056186
2#
2.0GPM
05056206
05056076
0.2 GPM
0.3 GPM
6
0844
30040081
30040082
Purple
00#
05056186
2#
2.0GPM
05056206
05056076
0.2 GPM
0.3 GPM
7
0935
30040083
30040084
Red
0#
05056186
2#
2.0GPM
05056206
05056076
0.2 GPM
0.3 GPM

BNT165/BNT265 Series Valve Operation Manual
- 11 -
8
1015
30040079
30040080
Gray
000#
05056187
3#
2.4GPM
05056206
05056076
0.2 GPM
0.3 GPM
9
1017
30040079
30040080
Gray
000#
05056187
3#
2.4GPM
05056206
05056076
0.2 GPM
0.3 GPM
10
1026
30040085
30040086
White
1#
05056187
3#
2.4GPM
05056206
05056076
05056178
0.2 GPM
0.3 GPM
0.7 GPM
11
1035
30040085
30040086
White
1#
05056187
3#
2.4GPM
05056206
05056076
05056178
0.2 GPM
0.3 GPM
0.7 GPM
12
1044
30040085
30040086
White
1#
05056187
3#
2.4GPM
05056206
05056076
05056178
0.2 GPM
0.3 GPM
0.7 GPM
13
1054
30040085
30040086
White
1#
05056187
3#
2.4GPM
05056206
05056076
05056178
0.2 GPM
0.3 GPM
0.7 GPM
14
1144
30040087
30040088
Blue
2#
05056169
5#
3.5GPM
05056206
05056076
05056178
0.2 GPM
0.3 GPM
0.7 GPM
15
1252
30040089
30040090
Yellow
3#
05056170
6#
4.0GPM
05056206
05056076
05056178
0.2 GPM
0.3 GPM
0.7 GPM
16
1354
30040089
30040090
Yellow
3#
05056171
7#
5.0GPM
05056206
05056076
05056178
0.2 GPM
0.3 GPM
0.7 GPM
17
0713
30040079
30040080
Gray
000#
05056185
1#
1.5GPM
05056206
05056076
0.2 GPM
0.3 GPM
For reference only:Different Size DLFC is available for different Filter tanks as follows
Tank Size
Serial number
DLFC size
07series
05056187
3# 2.4GPM
08series
05056188
4# 3.0GPM
09series
05056169
5# 3.5GPM
10series
05056170
6# 4.0GPM
11series
05056171
7# 5.0GPM
12series
NO DLFC
NO DLFC

BNT165/BNT265 Series Valve Operation Manual
- 12 -
5. Bypass Assembly
Bypass valve is provided with many functions such as bypass, water hardness adjustment.
Different angles of bypass knob have different functions (see following picture). The bigger
angle (value A), the higher water hardness in hardness adjustment position.

BNT165/BNT265 Series Valve Operation Manual
- 13 -
Valve Powerhead Assembly
Bnt165 Powerhead Assembly
Bnt265 Powerhead Assembly

BNT165/BNT265 Series Valve Operation Manual
- 14 -
Bnt165 Powerhead Assembly Parts List
Item No.
Part No.
Part Description
Quantity
B01
05056136
Screw-ST3.5×13(Hexagon with Washer)
4
B02
05056014
Bnt65 Back Cover
1
B03
05010045
Piston Stem Holder
1
A26
13000426
Screw-ST2.9×13(Large Wafer)
1
B04
05056139
Washer-3x13
1
B05
05056005
Main Gear
1
B06
05056083
Screw-M4x14
1
B07
05056166
Screw-ST4.2×12(Large Wafer)
1
B08
05056141
Washer-4x12
1
B09
13111004
Washer-4x9
1
B10
05056016
Refill Regulator
1
B11
05056015
Brine Gear
1
B12
05056089
Nut-M4
1
B13
05056095
Spring Detent
2
B14
05056001
Bnt65 Housing
1
B15
05010037
Screw-ST2.9×10
5
B16
05056504
Bnt165 Pcb
1
B17
05056500
Bnt165 Front Cover
1
05056505
Bnt165 Operation Label
1
05056506
Bnt165 Regen. Label
1
B18
05056509
Screw-ST2.9×10(CSK )
2
B19
05056082
Screw-M3×5
2
B20
05056510
Motor-12v/2rpm
1
11700005
Wire Connector
2
B21
05056045
Motor Mounting Plate
1
B22
05056501
Bnt165 Drive Gear
1
A04
05010081
Bnt65 Piston Rod
1
B23
05056002
Idler Gear
1
B24
05010031
Meter Assembly
1
05010046
Meter Strain Relief
1
B25
05056094
Spring Idler
1
B26
05056098
Motor Pin
1
B27
05056502
Spring Retainer
1
B28
05056507
Bnt165 Power Cable
1
05056013
Bnt65 Power Strain Relief
1
B29
05056092
Ball-1/4inch
2
B30
05056503
Magnet Holder
1
B31
05010023
Magnet-φ3×2.7
1
B32
05056008
Bnt65 Knob
1
05056111
Bnt65 Knob Label
1
B33
05056084
Screw-ST3.5x13
1

BNT165/BNT265 Series Valve Operation Manual
- 15 -
Bnt265 Powerhead Assembly Parts List
Item No.
Part No.
Part Description
Quantity
B01
05056136
Screw-ST3.5×13(Hexagon with Washer)
4
B02
05056014
Bnt65 Back Cover
1
B03
05010045
Piston Stem Holder
1
A26
13000426
Screw-ST2.9×13(Large Wafer)
1
B04
05056139
Washer-3x13
1
B05
05056005
Main Gear
1
B06
05056083
Screw-M4x14
1
B07
05056166
Screw-ST4.2×12(Large Wafer)
1
B08
05056141
Washer-4x12
1
B09
13111004
Washer-4x9
1
B10
05056016
Refill Regulator
1
B11
05056015
Brine Gear
1
B12
05056089
Nut-M4
1
B13
05056095
Spring Detent
2
B14
05056001
Bnt65 Housing
1
B15
05056554
Locking Knob
1
B16
05056561
Screw-ST3.5×15(CSK )
1
B17
05056556
Bnt265 Main Pcb
1
05056557
Bnt265 Wiring Harness
1
B18
05056551
Bnt265 Front Cover
1
05056506
Bnt165 Regen. Label
1
B19
05056082
Screw-M3×5
2
B20
05056510
Motor-12v/2rpm
1
11700005
Wire Connector
2
B21
05056045
Motor Mounting Plate
1
B22
05056501
Bnt165 Drive Gear
1
A04
05010081
Bnt65 Piston Rod
1
B23
05056002
Idler Gear
1
B24
05010031
Meter Assembly
1
05010046
Meter Strain Relief
1
B25
05056094
Spring Idler
1
B26
05056098
Motor Pin
1
B27
05056502
Spring Retainer
1
B28
05056507
Bnt165 Power Cable
1
05056013
Bnt65 Power Strain Relief
1
B29
05056092
Ball-1/4inch
2
B30
05056503
Magnet Holder
1
B31
05010023
Magnet-φ3×2.7
1
B32
05056509
Screw-ST2.9×10(CSK )
2
B33
05010037
Screw-ST2.9×10
2
B34
05056553
Bnt265 Controller Housing
1
B35
05056555
Bnt265 Display
1
B36
05056552
Bnt265 Controller Cover
1
05056559
Bnt265 Label
1
05056560
Bnt265 LOGO
1

BNT165/BNT265 Series Valve Operation Manual
- 16 -
Valve Body Assembly

BNT165/BNT265 Series Valve Operation Manual
- 17 -
Bnt165/Bnt265 Valve Body Assembly Parts List
Item No.
Part No.
Part Description
Quantity
A01
05056087
Screw-M5×12(Hexagon)
3
A02
05056088
Screw-M5×16(Hexagon with Washer)
2
A03
05056047
End Plug Retainer
1
A04
05010081
Bnt65 Piston Rod
1
A05
05056097
Piston Pin
1
A06
05056023
End Plug
1
A07
05056070
Quad Ring
2
A08
05056024
End Plug Washer
1
A09
05056022
Piston Retainer
1
A10
05056520
Piston (Electrical C)
1
A11
05056104
Muffler
1
A12
05056021
Spacer
4
A13
05056073
Seal
5
A14
05056019
Bnt65 Valve Body
1
A15
05056063
O-ring-φ78.74×5.33
1
A16
05056129
O-ring-φ23×3
4
A17
05056025
Adaptor Coupling
2
A18
05056044
Adaptor Clip
2
A19
13000327
Screw-M4×12(Hexagon with Washer)
2
A20
21709003
Secure Clip
2
A21
05056140
Valve Connector
1
A22
26010143
O-ring-φ22.4×3.55
2
A23
21319006
Screw Adaptor
2
A24
26010103
O-ring-φ25×3.55
1
A25
07060007
Valve Bottom Connector
1
A26
13000426
Screw-ST2.9×13(Large Wafer)
2
A27
05010082
Drain Fitting-B
1
A28
05056134
O-Ring-φ12×2
2
A29
05056172
Secure Clip-S
1
A30
05056186
DLFC-2#
1
A31
05056035
BLFC Button Retainer
1
A32
05056191
BLFC-2#
1
A33
05056138
O-Ring-φ14×1.8
1
A34
05056100B
BLFC Fitting
1
A35
05056106
Brine Line Screen
1
A36
05056107
BLFC Tube Insert
1
A37
05056033
BLFC Ferrule
1
A38
05056108
BLFC Fitting Nut
1
A39
05056086
Screw-M5×30(Hexagon with Washer)
2
A40
05056029
Injector Cover
1
A41
05056205
O-Ring-φ23.9×1.8
1

BNT165/BNT265 Series Valve Operation Manual
- 18 -
A42
05056103
Injector Screen
1
A43
05056027
Injector Nozzle
1
A44
05056028
Injector Throat
1
A45
05056177
Injector Body-B
1
A46
05056075
Injector Seat
1
A47
05056054
Injector Stem
1
A48
05056031
Injector Spacer
1
A49
05056081
O-Ring-φ12.5×1.8
1
A50
05056030
Injector Cap
1
A51
05056093
Injector Screen
1
A52
05010049
Special Washer
1
A53
05056105
Retaining Ring
1
A54
05056067
O-Ring-φ7.8×1.9)
2
A55
05056037
Air Disperser
1
A56
05056066
O-Ring-φ11×2
1
A57
05056165
Injector Body (Filter)
1

BNT165/BNT265 Series Valve Operation Manual
- 19 -
Bypass Assembly
This manual suits for next models
1
Table of contents