manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Commend
  6. •
  7. Control Unit
  8. •
  9. Commend C-WSEBIL User manual

Commend C-WSEBIL User manual

www.commend.com
The design and/or specications of products may be subject to change for improvement without prior notice. Errors excepted.
WSEBIL V10-0414 Page 1 |4
Security and Communication
WSEBIL
Induction Loop Amplier Module for barrier-free communication
Commend – Communication and security for everyone
Induction loop amplier modules for sound transmission to hearing aids are
an essential part of Commend’s product portfolio. Upgrading WS stations to
barrier-freeness has never been easier. As an add-in circuit board with on-board
induction loop, the module may be small in size but is a huge advantage for us-
ers of hearing aids. Designed specically for public locations such as building
reception areas or on-street help points, the modules deliver Intercom audio in
high Commend quality directly to hearing aids. Being hard of hearing doesn’t
have to be a barrier – especially with Commend induction loop modules. Take
the opportunity to upgrade your system to barrier-freeness and provide opti-
mum conditions for all Intercom users with the benets of the world’s leading
Intercom technology.
Features and Highlights
– A fully integrated, IEC 60118-4 compliant induction loop system enables
wearers of hearing aids to receive Intercom audio signals in clear, uninter-
rupted quality.
– Flexible integration into vandal resistant or polycarbonate WS stations
without camera or TFT-display
– Energy-efcient and power-saving technology with low heat generation.
– Functions as MLC (Metal Loss Correction) and AGC (Automatic Gain
Control) for easy startup and faultless operation.
–
IEC 60118-4
compliant
Flexible
integration
www.commend.com
The design and/or specications of products may be subject to change for improvement without prior notice. Errors excepted.
WSEBIL V10-0414 Page 2 |4
Security and Communication
Technical data / System requirements
Technical Data
Input: Input impedance 10kΩ
Sensitivity - 15dBu for max output
Overload level +10dBu
Output: Drive Voltage: max. 6.5 Vrms
Drive Current: 2.8 A continuous 1kHz sine wave
Loop resitance: 0.1Ω to 1.0Ω resistive or 1.5Ω maximum reactive impedance
Frequency response: 80 Hz to 8 kHz: - 3dB
MLC (Metall loss correction): 0 to -3dB/ octave
Operating temperature range: –20° C to 70° C (–4° F to 158° F)
Storage temperature range: –20° C to 70° C (–4° F to 158° F)
Relative humidity: up to 95% not condensing
Connection: - pluggable screw terminals
- JST plug (type: PAP-02v-s)
Power supply: external supply 15 – 26 VDC
(max. power consumption 8 W)
Extent of supply
– Induction Loop Amplier Module
– Induction Loop and mounting kit
– Sticker with hearloop symbol
– Line-In connection cable
Requirements
– Power supply: 15 VDC - 26 VDC
– WS station without camera or TFT-display
– Flush Mount Kit (WSFB 50x) or Surface Mount Kit (WSSH 50x)
Mounting instructions / Restrictions
– Do not expose the station to extreme temperature.
– Observe the country specic standards for installation, mounting and
conguration.
– When opening the stations ESD precautions must be observed.
– The housing may only be opened by authorised service engineers.
– Induction Loop Performance compliant with IEC 60118-4 (when correctly
installed)
– Metal Structures signicantly affects performance of the induction loop
system. The magnetic eld generated by an induction loop system,
induces a current in any closed path of a metal structure placed in the
vicinity of the induction loop. These induced currents tend to weaken the
magnetic eld and cause loss.
Examples of metal structures:
– Lightweight oor construction with a (usually proled) metal sheet
under a thin reinforced concrete slab.
– Girders, beams, constructional metal work
– Metal cladding and walls
– Metal box construction (elevators, lifts)
www.commend.com
The design and/or specications of products may be subject to change for improvement without prior notice. Errors excepted.
WSEBIL V10-0414 Page 3 |4
Security and Communication
Please follow the following instruction for the installation of the Induction Loop Amplier module:
– Open the WS station - instruction see respective short reference
– Disconnect the station from the Intercom network and if used, from the external power supply.
– Mount the Induction Loop on the surface or ush mount box as shown in the following picture
– Snap the Induction Loop Amplier module in the slot of the WS station:
– It is only possible to snap the module in the middle slot of the WS station!
– If in the middle slot a Camera module or a TFT-Display module is used, it is not possible to mount the induction loop amplier module.
Quick Start
Note:
It is mandatory to install the induction loop on the right side of
the housing, as shown in the connection diagram. Otherwise
disturbing hum may occur. For the installation use the attached
mounting clips and screws (in extent of supply).
Induction loop
Mounting clip
Surface or Flush Mount Kit
www.commend.com
The design and/or specications of products may be subject to change for improvement without prior notice. Errors excepted.
WSEBIL V10-0414 Page 4 |4
Security and Communication
Quick Start
Quality tested. Reliable. Smart.
COMMEND products are developed and manufactured by Commend
International in Salzburg, Austria.
The development and manufacturing processes are certified in
accordance with EN ISO 9001:2015.
A strong worldwide network
COMMEND is represented the world over by local Commend Partners and
helps to improve security and communication with tailored Intercom solutions.
ALGERIA AUSTRALIA AUSTRIA BELGIUM BRAZIL CANADA CHINA CROATIA CZECH
REPUBLIC DENMARK FINLAND FRANCE GERMANY HUNGARY ICELAND INDIA IRELAND
ISRAEL ITALY LIECHTENSTEIN LUXEMBURG MOROCCO NETHERLANDS NEW ZEALAND
NORWAY POLAND PORTUGAL RUSSIA SERBIA SINGAPORE SLOVAKIA SLOVENIA SPAIN
SOUTH AFRICA SWEDEN SWITZERLAND TUNISIA UNITED KINGDOM USA
www.commend.com
– Carry out the connection of the induction loop, signal input and power supply
– Connect the loop cable (polarity does not matter) via the screw terminals as shown in the following picture.
– Connect Line-In with the connection cable (in the extent of supply) - as shown in the following picture.
– Connect power supply (15 VDC - 26 VDC) as shown in the following picture.
Note: If an external power supply is used for the terminal, it is possible to use this power supply also for the Induction Loop Amplier Module.
– Switch on the external power supply and check if the green “Power” LED illuminates!
– The potentiometers “Level-Input”, “MLC” and “Loop Current” are preset at factory delivery.
– Test the performance of the system using a loop receiver or eld strength meter and adjust ‘MLC’ & ‘LOOP CURRENT’ to achieve acceptable performance -
please consider the respective norm!
– Mount the Intercom Station - see short reference Surface / Flush Mount Kit.
– Place the sticker with the hearloop symbol onto the frontplate of the Intercom Station.
BOC1
BOC2
11
BMK1
BAD-
MARK
BOC1
BOC2
1
6
11
1
1
1
B
O
C
1
B
O
C
2
1
1
BMK
1
BA
D
-
M
A
R
K
B
O
C
1
B
O
C
2
1
6
1
1
1
1
1
LED “Power”
MLC
Level-Input
Loop
Current
LED
“A djust”
IN 1
IN 2
IN 3
GND
OUT 1
OUT 2
OUT 2
IN
1
IN
2
IN
3
G
N
D
OUT
1
1
OU
T 2
O
UT 2
MUTE
GND
LINE–
LINE IN
LINE+
DC+
DC–
-- +
-- +
IP Uplink
(to Intercom Server)
External power supply
15 V DC – 26 V DC
Expansion plug
for EB 2E2A
for fixing
cable straps
External power supply
15 V DC – 26 V DC Output
Induction loop
Induction loop
Mounting clip
Surface or Flush Mount Kit

Other Commend Control Unit manuals

Commend C-EB8E4A User manual

Commend

Commend C-EB8E4A User manual

Commend C-G3-TEL User manual

Commend

Commend C-G3-TEL User manual

Popular Control Unit manuals by other brands

Omron G9SX Series manual

Omron

Omron G9SX Series manual

Environ ENVIRONCONNECTEDModule installation instructions

Environ

Environ ENVIRONCONNECTEDModule installation instructions

Zetkama zGLO user manual

Zetkama

Zetkama zGLO user manual

Trumbull 367-1414 Installation, operation and maintenance manual

Trumbull

Trumbull 367-1414 Installation, operation and maintenance manual

Fenwal 35-65 Series manual

Fenwal

Fenwal 35-65 Series manual

Niko 78300 Series manual

Niko

Niko 78300 Series manual

SIKA VT 40 Series operating manual

SIKA

SIKA VT 40 Series operating manual

EOS Emotec D Installation and operation manual

EOS

EOS Emotec D Installation and operation manual

DSE DSEPOWER DSE871 Series manual

DSE

DSE DSEPOWER DSE871 Series manual

Velleman K8095 Assembly manual

Velleman

Velleman K8095 Assembly manual

Tellabs 4119 Technical manual

Tellabs

Tellabs 4119 Technical manual

National Instruments NI PCIe-1430 user manual

National Instruments

National Instruments NI PCIe-1430 user manual

Viessmann SM1 Installation and service instructions

Viessmann

Viessmann SM1 Installation and service instructions

Tyco Grinnell F540 quick start guide

Tyco

Tyco Grinnell F540 quick start guide

Hach sc200 user manual

Hach

Hach sc200 user manual

Nexta Tech LOGIC-400-ONE manual

Nexta Tech

Nexta Tech LOGIC-400-ONE manual

Eurotronic NOX WR manual

Eurotronic

Eurotronic NOX WR manual

Burkert 6240 operating instructions

Burkert

Burkert 6240 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.