3
ATTACH SUBBASE TO WALL
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
mainfuse orcircuit breakerbox untilinstallation
is complete.
1. Disconnect electrical power at main fuse or circuit
breaker.
2. Pull wires through opening near center of subbase
andconnectwiresbeneathterminalscrews(seefigs.
2through6fortypicalwiringforeachapplication.Also
refertosubsectionsbelowforspecialsystemconfigu-
rations).
3. Push excess wiring into wall and plug hole with fire-
resistant material (such as fiberglass insulation) to
prevent drafts from affecting thermostat operation.
4. Positionsubbaseoverholeinwallandmarkmounting
hole locations on wall.
5. Drill mounting holes.
6. Fasten subbase loosely to wall, as shown, using two
mounting screws. Place a level against bottom of
subbase,adjustuntillevel,andthentightenmounting
screws to secure subbase. If holes in wall are too
largeand donotallowyoutotightensubbasesnugly,
use plastic screw anchors to secure subbase.
SPECIAL SYSTEM CONFIGURATIONS
Electric Heat Furnaces (Single Transformer Systems
Only)
The subbase as shipped may not operate the fan cor-
rectly. If both the heating and cooling system must oper-
ate the fan relay, remove the yellow factory-installed
jumper wire from the Yterminal and connect it to the A
terminal. The fan should now cycle when the thermostat
calls for either heat or cool.
Two-Transformer Systems
If two transformers are used, they MUST be in
phase. Failure to do so may result in personal
injury and/or property damage.
Wire color DOES NOT indicate polarity. Polarity is ob-
tained from an oscilloscope or voltmeter.
Heat Pump Applications
This subbase WILL NOT provide multi-stage heating or
cooling operation. For single-stage heat pump applica-
tions, install a short jumper wire across terminals Wand
Y.If theoldthermostathas aterminalthat iscontinuously
energized, disconnect the wire from the old thermostat's
terminal and connect it either to the: 1) Bterminal, if the
reversingvalveisenergizedona callforheat; or tothe 2)
Oterminal,ifthe reversingvalveisenergized on acallfor
cool. If the system heats on a call for cool, or vice versa,
this wire has been connected to the wrong terminal.
RHand RC mustbe jumperedforsingletransformerheat
pump systems.
Special Application Terminals
The Band Oterminals can provide switching for special
functions other than heat pump operation. When the
system switch is in the HEAT position, the Bterminal is
energized. When the system switch is in the COOL
position, the Oterminal is energized.
ATTACH THERMOSTAT TO SUBBASE
1. Remove cover from thermostat base by gripping the
basein onehand.Usetheotherhandto pullgentlyat
the top or bottom of the cover.
2. Carefully remove the shipping protective packing
from the switch.
3. Attachthermostatbasetosubbase,beingsurethatall
captivescrewsaretightenedsnugly,sincetheyserve
as electrical connections between thermostat and
subbase (see fig. 7).
4. Snap cover on thermostat and set switches and
temperature lever to desired set point (see OPERA-
TION section).
5. Turn on power to the system.