7
CONFIGURATIONMENUCONFIGURATIONMENU
CONFIGURATIONMENUCONFIGURATIONMENU
CONFIGURATIONMENU
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
Electrical RatingElectrical Rating
Electrical RatingElectrical Rating
Electrical Rating:
20 to 30 VAC 50/60 Hz or DC
0.05 to 1.5 Amps (Load per terminal)
2.5 Amps Maximum Total Load (All terminals combined)
ELECTRICAL DATAELECTRICAL DATA
ELECTRICAL DATAELECTRICAL DATA
ELECTRICAL DATA
Setpoint Temperature RangeSetpoint Temperature Range
Setpoint Temperature RangeSetpoint Temperature Range
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature RangeOperating Ambient Temperature Range
Operating Ambient Temperature RangeOperating Ambient Temperature Range
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity RangeOperating Humidity Range
Operating Humidity RangeOperating Humidity Range
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature RangeShipping Temperature Range
Shipping Temperature RangeShipping Temperature Range
Shipping Temperature Range:
-40°F to 150°F
THERMAL DATATHERMAL DATA
THERMAL DATATHERMAL DATA
THERMAL DATA
OPERATIONOPERATION
OPERATIONOPERATION
OPERATION
The system "mode" is selected by pressing the SYSTEM
button. Icons on the bottom right corner of the display will
indicate the mode: COOLCOOL
COOLCOOL
COOL( ), AUTOAUTO
AUTOAUTO
AUTO ( ), HEATHEAT
HEATHEAT
HEAT( ), EMEREMER
EMEREMER
EMER,
or OFFOFF
OFFOFF
OFF. In any mode except OFFOFF
OFFOFF
OFF, the setpoint temperature will
be shown on the right side of the display. In OFFOFF
OFFOFF
OFF, this area will
be blank. The current temperature will be displayed on the left
side of the display.
To operate properly in the AUTOAUTO
AUTOAUTO
AUTO mode, the heat setpoint
temperature cannot be the same as or higher than the cool
setpoint temperature. The heat setpoint must be at least 1°
lower than the cool setpoint.
Automatic System ChangeoverAutomatic System Changeover
Automatic System ChangeoverAutomatic System Changeover
Automatic System Changeover
When the thermostat is in the AUTOAUTO
AUTOAUTO
AUTO mode, both the FlameFlame
FlameFlame
Flame and
SnowflakeSnowflake
SnowflakeSnowflake
Snowflake icons are displayed. The thermostat will call for heat
or cool depending on the room temperature. The setpoint
temperature displayed will be that of the last mode called. If the
last system cycle was heat, the HEATHEAT
HEATHEAT
HEATsetpoint will be displayed.
If the room temperature raises above the HEATHEAT
HEATHEAT
HEAT setpoint and
the COOLCOOL
COOLCOOL
COOL setpoint and a call for cool is required, the tempera-
ture displayed will change to be the COOLCOOL
COOLCOOL
COOL setpoint.
10)Select Temporary Program Override TimeSelect Temporary Program Override Time
Select Temporary Program Override TimeSelect Temporary Program Override Time
Select Temporary Program Override Time – The thermo-
stat can hold any temperature you set it to for the amount
of time you select on this option. Your choices are 0:15 to
8:00 hours in 15 minute increments.
Example:
1. You have selected 3:00 hours for the Temporary Pro-
gram Override time period.
2. With the thermostat set to Heat or Cool, press HOLD
for approximately 5 secondsfor approximately 5 seconds
for approximately 5 secondsfor approximately 5 seconds
for approximately 5 seconds until HOLD time (3:00
indicating 3 hours) appears as a setting reminder.
3. After releasing the button, HOLDHOLD
HOLDHOLD
HOLD on the display will blink.
4. Use or to set the temperature to your preference.
The thermostat will maintain this temperature setting for
3 hours with HOLDHOLD
HOLDHOLD
HOLD blinking to remind you it is in
Temporary Hold. After 3 hours, the thermostat will go
back to the program temperature and HOLDHOLD
HOLDHOLD
HOLD will no
longer blink or display.
11)Select F° or C° ReadoutSelect F° or C° Readout
Select F° or C° ReadoutSelect F° or C° Readout
Select F° or C° Readout – Changes the display readout to
Centigrade or Fahrenheit as required.
12)Limited Heat RangeLimited Heat Range
Limited Heat RangeLimited Heat Range
Limited Heat Range – This feature provides a maximum
setpoint temperature for heat. The default setting is 90°F. It
can be changed between 62°F and 89°F by pressing the
temperature uptemperature up
temperature uptemperature up
temperature up or temperature downtemperature down
temperature downtemperature down
temperature down key.
13)Limited Cool RangeLimited Cool Range
Limited Cool RangeLimited Cool Range
Limited Cool Range – This feature provides a minimum
setpoint temperature for cool. The default setting is 45°F. It
can be changed between 46°F and 82°F by pressing the
temperature up or temperature down key.
14)This feature not availableThis feature not available
This feature not availableThis feature not available
This feature not available.
15 & 16) Keypad LockoutKeypad Lockout
Keypad LockoutKeypad Lockout
Keypad Lockout – This menu selection will display
locklock
locklock
lock icon. The and are used to toggle the function and
display the locklock
locklock
lock icon and OFFOFF
OFFOFF
OFF (keypad not locked out,
default) indicating in the time digits to the locklock
locklock
lock icon and ONON
ONON
ON
(keypad locked out). When the keypad lockout function is
enabled (ONON
ONON
ON), and the SYSTEMSYSTEM
SYSTEMSYSTEM
SYSTEM key is pressed again, the
display will indicate the number 00
00
0 (default, still disabled) in
the time digits. The and are used to set the combina-
tion number from 00
00
0 to 999999
999999
999. "00
00
0" will not be a valid combination.
If a combination of 00
00
0 is selected and the system key is
pressed the menu will be exited and keypad lockout will not
be evoked. If 1 to 9991 to 999
1 to 9991 to 999
1 to 999 is selected and the SYSTEMSYSTEM
SYSTEMSYSTEM
SYSTEM key is
pressed again, the combination is locked into non-volatile
memory and the menu is exited. The locklock
locklock
lock icon (to designate
keypad locked with a valid combination) will display when
the menu is exited. The system key will operate for 10
seconds after the menu mode is exited to allow the user to
change the mode from OFFOFF
OFFOFF
OFF to the desired system mode.
While the keypad is locked out, a simul-
taneous press of the temperature and will enter the
menu item from any mode instead of only OFF modeOFF mode
OFF modeOFF mode
OFF mode. When
the menu is entered with the keypad lockout feature en-
abled, the first menu item displayed is the combination
code 00
00
0. The or keys are used to set the combination
unlock number from 00
00
0 to 999999
999999
999. If the unlock number matches
exactly with the combination lock number stored in memory
when the SYSTEMSYSTEM
SYSTEMSYSTEM
SYSTEM key is pressed, the keypad is unlocked
and the locklock
locklock
lock icon is removed. If the unlock number does not
match when the SYSTEMSYSTEM
SYSTEMSYSTEM
SYSTEM key is pressed, menu is exited
and the keypad remains disabled.
To reset the combination code and unlock the keypad if the
code is forgotten, see troubleshooting section.