GE RAK148D2 Original instructions

Digital Non-Programmable
GEAppliances.com
Configuration Mode........................ 8–9
Important Safety
Information.................................................. 2
Installation Instructions................ 4–7
Introduction Overview.......................... 3
Operating Functions.......................... 10
Specifications............................................. 2
Testing the Thermostat ............11–12
Troubleshooting Tips.......................... 13
Warranty.................................................... 17
RAK148D2
RAK164D2
Owner’s Manual &
Installation Instructions
LIA307 49-7731 12-13 GE
Thermostats

2
Important safety information.
Specifications.
WARNING!
FIRE AND SHOCK HAZARD
• Always turn off power at the main power supply before
installing, cleaning or removing the thermostat.
• Do not use on voltages over 30 VAC. Higher voltages will
damage the thermostat and could cause shock or fire hazard.
• All wiring must conform to local and national electrical
and building codes.
• Use this thermostat only as described in this manual.
Electrical rating: • 24 VAC (18–30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
Operating temperature range: 40°F–99°F (4°C–37°C)
Temperature set range: 60°F–85°F (15°C–29°C)
Accuracy: ± 1°F (± 0.5°C)
System configurations:
RAK148D2: 2-stage heat (heat pump/resistance heat), 1-stage cool
RAK164D2: 1-stage heat (resistance heat), 1-stage cool
Terminations: R, C, W, Y, G, B (RAK148D2);
R, C, W, Y, G (RAK164D2)
Wiring: Maximum wiring length is 66ft (20 meters) for AWG18
Maximum wiring length is 60ft (18 meters) for AWG20

PARTS DIAGRAM
INTRODUCTION OVERVIEW
3
THERMOSTAT CONTROL
Auto
Cool Off
Heat
On
Display Up/Down Buttons
Function Switch Fan Auto/On Switch
B G
Y
W C
R
COOL OFF
HEAT
RESETRIGHTLEFT
AUTO ON
Display Up/Down Buttons
Wiring
Channel
Mounting
Hole
Function
Switch
Fan Auto/On Switch
Mounting
Hole
Configuration
Buttons

4
INSTALLATION INSTRUCTIONS
TO INSTALL THERMOSTAT
IMPORTANT: Thermostat installation must conform to
local and national building and electrical codes and ordinances.
Note: Mount the thermostat about five feet above the floor.
Do not mount the thermostat on an outside wall, in direct
sunlight, behind a door or in an area affected by a vent or duct.
WARNING!
(/(&75,&$/6+2&.+$=$5'³7XUQRIISRZHUE\
unplugging the unit or by removing the fuse or
switching the appropriate circuit breaker to the OFF
position before removing the existing thermostat.
TO REMOVE EXISTING THERMOSTAT
1. Turn off power to heating and cooling system by removing
the fuse or switching off the appropriate circuit breaker.
2. Remove cover of old thermostat. This should expose the wires.
3. Label the existing wires with the enclosed wire labels
before removing wires.
4. After labeling wires, remove wires from wire terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how
to install this thermostat.
PACKAGE CONTENTS/TOOLS REQUIRED
Package includes: Thermostat on base, thermostat cover,
wiring labels, screws and wall anchors.
Tools needed: Drill with 3/16sbit, hammer, screwdriver and
putty.

5
TO INSTALL THERMOSTAT (cont.)
1. Turn off power to the heating and cooling system
by removing the fuse or switching off the appropriate
circuit breaker.
2. Move the Function switch on the thermostat to Off.
3. Remove the cover by inserting and twisting a coin or
screwdriver in the slots on the top of the thermostat.
4. Put thermostat base against the wall where you plan
to mount it. Make sure wires will feed through the wire
opening in the base of the thermostat.
5. With the base level, mark the placement of the
mounting holes.
6. Set thermostat base and cover away from working area.
7. Using a 3/16sdrill bit, drill holes in the locations you
have marked for mounting.
8. Use a hammer to tap supplied anchors in mounting holes.
9. Align thermostat base with mounting holes and feed
the control wires through the wire opening.
10. Seal hole for wires behind thermostat with non-flammable
insulation or putty, or use a wall plate obtainable from
a local hardware or home building store.
11. Use supplied screws to mount thermostat base to wall.
12. Insert stripped, labeled wires in matching wire terminals
by pressing on the corresponding terminal contact. See
the “Wiring Diagrams” section of this manual.
CAUTION! Make sure exposed portion
of wires does not touch other wires.
13. Gently tug wire to be sure of proper connection.
Double check that each wire is connected to the
proper terminal.

6
TO INSTALL THERMOSTAT (cont.)
14. Replace cover on thermostat by snapping it in place.
15. Plug the unit in or turn on power to the system at the
main service panel.
16. Test thermostat operation as described in the “Testing
the Thermostat” section.
INSTALLATION INSTRUCTIONS
Wiring diagrams.
Table 1: Terminals for five wires 1-stage heat/1-stage
cool system (RAK164D2 only)
Note: Connect G terminal of thermostat to Zoneline GL
terminal for low fan speed or terminal GH for high fan speed.
Only one can be selected.

7
Table 2: Terminals for six wires 2-stage heat/1-stage
cool system (RAK148D2 only)
B G Y W C R
Note: Connect G terminal of thermostat to Zoneline GL
terminal for low fan speed or terminal GH for high fan speed.
Only one can be selected.

Configuration mode.
The configuration mode is used to set the RAK148D2 and RAK164D2
to match the heating/cooling system. These thermostats function
with up to 2-stage heat pump systems (RAK148D2 only).
To configure the RAK148D2 and RAK164D2, perform the
following steps:
Note: Operation being set will blink in the display.
1. Slide the Function switch to the OFF position.
2. Remove the thermostat’s front cover.
3. To enter the configuration mode, simultaneously hold
the LEFT and RIGHT buttons in for 6 seconds while the
thermostat is in OFF mode. (See diagram on page 3.)
4. Once in the configuration mode, press the
<
or
>
button
to change settings within each screen.
-Press the RIGHT button to advance to the next screen.
- Press the LEFT button to return to the previous screen.
NOTE: To exit configuration mode at any time, slide the
Function switch to Heat or Cool.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1. 7HPSHUDWXUH6FDOH)RU&³Choose
Fahrenheit or Celsius.
Press the
<
or
>
button
to select.
Press the RIGHT button to advance to the next screen.
NOTE: Default factory setting is Fahrenheit.
2. 7HPSHUDWXUH'LIIHUHQWLDO³6WDJH³²)
²&
Set the number of degrees between the
“setpoint” temperature and the
“turn on” temperature for first stage.
Press the
<
or
>
button to set differential value.
Press the RIGHT button to advance to the next screen.
Note: Default factory setting is 2°F/1°C for each stage.
8

7HPSHUDWXUH'LIIHUHQWLDO³6WDJH
²)²& RAK148D2 only
Set the number of degrees between when
stage 1 turns on and stage 2 turns on.
Press the
<
or
>
button to set
differential value.
Press the RIGHT button to advance to the next screen.
Note: Default factory setting is 2°F/1°C for each stage.
4. Minimum Cool Setpoint (60, 64, 66, 68,
)
&
Adjust to control the minimum Cool set
temperature allowed.
Press the
<
or
>
button to select.
Press the RIGHT button to advance to the next screen.
Note: Default factory setting is 60°F/15°C.
5. Maximum Heat Setpoint (65, 70, 72, 74,
)
&
Adjust to control the maximum Heat set
temperature allowed.
Press the
<
or
>
button to select.
Press the RIGHT button to advance to the next screen.
Note: Default factory setting is 85°F/29°C.
5RRPWHPSHUDWXUHRIIVHW)WR²)
&WR²&
Adjust to calibrate displayed room
temperature to match actual room
temperature.
Press the
<
or
>
button to select.
Press the RIGHT button to advance to the next screen.
Note: Default factory setting is 0°F/0°C.
9

10
Operating functions.
Off
• In this mode, the thermostat will not turn on the heating or
cooling devices (manual fan can operate).
• Off is also used to access Configuration mode.
Cool
• In this mode, the thermostat
controls the cooling system.
• Press the
<
or
>
button to
set the desired temperature.
Heat
• In this mode, the thermostat
controls the heating system.
• Press the
<
or
>
button
to set the desired temperature.

Once the thermostat is installed, it should be thoroughly tested.
CAUTION! Do not use air conditioning
beyond the simple test when the outdoor temperature is below
50 degrees. This can damage the air conditioning system.
Note: Before testing the thermostat, move the Fan Auto/On
switch to the Auto position.
Fan Test
1. With Function switch set to Off, slide Fan
Auto/On switch to On position.
2. Indoor fan turns on.
3. Slide Fan Auto/On switch to Auto position.
4. Indoor fan turns off.
Cool Test
1. Slide Function switch to Cool
position. Cool mode screen is
displayed.
2. Adjust set temperature so it is 5 degrees below room
temperature.
3. Air conditioning should come on within a few seconds.
4. Adjust the set temperature so it is 2 degrees above the room
temperature and the A/C should turn off. Note: There is a 3
minute time delay and a 3 minute minimum run time for the
compressor when it turns on/off. (On some models, the fan
may also have a minimum run time/off time delay).
Testing the thermostat.
11

12
Testing the thermostat.
Heat Test
1. Slide Function switch to Heat
position. Heat mode screen is
displayed.
2. Adjust set temperature so it is 5 degrees above room temperature.
3. Heat should come on within a few seconds.
4. Adjust the set temperature so it is 2 degrees below the room
temperature and the heat should turn off. Note: There is a 3
minute time delay and a 3 minute minimum run time for the
compressor when it turns on/off. (On some models, the fan
may also have a minimum run time/off time delay).

13
Troubleshooting tips.
No display Check for 24 VAC; display is blank
when 24 VAC is not present.
System fan does not Verify that wiring is correct.
come on properly
All thermostat buttons Verify that 24 VAC is present; unit
are inoperative will not operate when 24 VAC is not
present
Thermostat turns on and Adjust temperature differential
off too frequently (see Configuration Mode - Setting
Temperature Differential, Stage 1 and
Stage 2 sections).
Fan runs continuously Check Fan Auto/On switch. If set to
ON position, fan will run continuously.
Room temperature is Verify that wall hole is plugged
not correct with putty or insulation to prevent
airflow from the wall cavity.
Adjust Temperature Offset (see
Configuration Mode - Room
temperature offset section).
Compressor doesn’t run There is a 3 minute time delay and
or turn off immediately a 3 minute minimum run time for
when changing function the compressor when it turns on/off.
or setting
Fan doesn’t run or turn off This is normal. On some models, the
immediately when changing fan may have a minimum run time/
function or setting off time delay.
Problem not listed above Press the Reset button once to reset
the thermostat and restore all factory
settings.
Problem Solution

14
Notes.

Notes.
15

Thermostat Warranty.
For The Period Of: GE Will Replace:
One Year Full Replacement of the thermostat which fails
From the date of the due to a defect in materials or workmanship.
original purchase
What GE Will Not Cover:
Service trips to your location.
Improper installation. If you have an installation problem, contact your
installer. You are responsible for providing adequate electrical connections
to the product.
Failure of the product resulting from modifications to the product or due to
unreasonable use, including failure to provide reasonable and necessary
maintenance.
In commercial locations, labor necessary to move the unit, after it has been
initially installed, to a location where it is accessible for service by an individual
technician; or, if the instructions included in this manual have been disregarded.
Replacement of location fuses or the resetting of circuit breakers.
Damage to the product caused by improper power supply voltage, accident,
fire, floods or acts of God.
Incidental or consequential damage caused by possible defects with this
thermostat.
Staple your receipt here.
Proof of the original purchase date is
needed to validate the warranty.
This warranty is extended to the original purchaser and any succeeding owner for
products purchased for use within the USA and Canada. In Alaska, the warranty
excludes the cost of shipping or service calls to your site.
Some states or provinces do not allow the exclusion or limitation of incidental or
consequential damages. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state or province to province. To know what
your legal rights are, consult your local, state or provincial consumer affairs office or
your state’s Attorney General.
Warrantor: General Electric Company. Louisville, KY 40225
(;&/86,212),03/,(':$55$17,(6³<RXUVROHDQGH[FOXVLYHUHPHG\LV
product exchange as provided in this Limited Warranty. Any implied warranties,
including the implied warranties of merchantability or fitness for a particular
purpose, are limited to one year or the shortest period allowed by law.
16
This manual suits for next models
1
Table of contents
Other GE Thermostat manuals

GE
GE RAK147P1 Operating instructions

GE
GE RAK148H2 Original instructions

GE
GE 60-909-95 User manual

GE
GE IS-ZW-TSTAT-300 User manual

GE
GE RAK348T1 User manual

GE
GE RAK149P2 Original instructions

GE
GE RAK160W2 Original instructions

GE
GE RARWT Series Original instructions

GE
GE RAK348T1 User manual

GE
GE RAK148F2 Operating instructions

GE
GE RAK148P1 Original instructions

GE
GE CC-SCSTAT User manual

GE
GE RAK180W1 Original instructions

GE
GE RAK190V User manual

GE
GE RAK348R1 User manual

GE
GE RARWT Series Original instructions

GE
GE PROGRAMMABLE THERMOSTAT User manual

GE
GE RARWT1W Original instructions

GE
GE RAL163P1 Original instructions

GE
GE RAK148D1 Original instructions