9
AUTOMATIC ICE AND WATER DISPENSER
PURESOURCE TM ICE AND WATER FILTER
(SOME MODELS)
Changing the Filter:
Waterconditionsvarythroughouttheworld,butchangingthe
waterlterevery6-9monthsnormallywillensurethehighest
possiblewaterquality.Ice jams in the ice maker and/or
hollow ice cubes (partially frozen cubes with water inside),
may also be a sign that your water filter needs changing.
TheFilterStatuslightwillturnredafter400gallonsofwater
hasowedthroughtheiceandwaterdispenser.Also,ifthelter
hasbeeninarefrigeratorthathasnotbeeninuseforawhile
(duringmovingforexample),changethelterbeforereinstalling
therefrigerator.Thedispensersystemwillalsooperatewithout
ltration(withltercartridgeremoved).
important
Resetting The Filter Status Light (some models)
Afterreplacingtheltercartridge,itwillbenecessarytopress
theFilter Statusresetbuttonlocatedontheiceandwater
dispenser.ThiswillresettheFilterStatuslight.Pushthereset
buttonuntilthegreen,redandamberlightsash(10-15
seconds).Pleaserefertothecompletedispenseroperating
instructionsattachedtotheinsideofthefreezerdoor.
On models without a Filter Status reset button, thereisa
setofReminderStickersincludedintheenvelopethattheUse
&CareManualcamein.Chooseadatedstickerthatindicates
6-9months(dependingonyourwaterqualityandusage)from
thedateofinstallation.Placethestickeronthefrontofthelter
cuptoremindyouwhenitistimetochangethelter.
Order new filter cartridges through the dealer
where you bought the refrigerator, contact the
Electrolux Solutions Hotline at 1-800-944-9044, or
go to our web site at www.frigidaire.com. It might
be good to order some filter cartridges when you
first install your refrigerator. Be sure to ask for the
RG-100 PureSource™ replacement cartridge.
ThePureSource™*NGRG-2000IceandWater
FilterSystemwiththeRG-100cartridgeistested
andcertiedbyNSFInternationaltoNSF/ANSI
Standard42forthereductionofclaimsspecied
ontheperformancedatasheet.
To change filter:
Itisnotnecessarytoturnthewatersupplyofftochangethe
lter.
1.Openfreezerdoorandleaveopenuntillterchangeis
complete.
2. TurnOFFsidemountedicemakerbyraisingwiresignal
armtotheUPposition.TurnOFFrearmountedicemaker
bypressingON/OFFpowerswitchtothe“O”position.
3. Holdltercuprmly,andunscrewtowardsleft.Some
watercouldleakoutasyouremovecup.Thisisnormal.
Filtercartridgeshouldcomedownwithcup.Ifcartridge
remainsinhousing,pulldowngently,whiletwistinglter
backandforth.
4. Rinseoutcupunderrunningwater.
5. Thelargeo-ringthatsealstheltersystemtsintheo-ring
grooveinsidethecup.Shouldtheo-ringfalloutduringlter
cartridgereplacement,simplyplaceitbackinthegroove
priortoscrewingthecupbackinplace.Iftheo-ring
becomesdamaged,youwillneedtoorderonefrom
theElectrolux Solutions Hotline.
6. Discardoldltercartridge.
7. Removenewltercartridgefrompackaging.Placeincup.
Theendwiththesmallo-ringshouldbeup,outofthecup.
8. Screwcup,withlter,backontohousing.Do Not Use
Wrench To Reinstall Cup.Filtercartridgewillself-alignas
cupistightened.Besurecupiscompletelytightenedwith
PureSource™logofacingoutward.Do Not Tighten Past
Stop.
9. TurnONsidemountedicemakerbyloweringwiresignal
armtotheDOWNposition.TurnONrearmountedice
makerbypressingON/OFFpowerswitchtothe“I”
position.
10. Checkforleaks.Openrefrigeratordoor.Wipeanywater
leaksfromtheltercup.Fillaglasswithwater.Ifthereisa
leak,unscrewltercup,andreinsertthelter
cartridge.CheckplacementoflargeO-ring.Reinstalllter
cup,makingcertainitistightenedcompletely.
11. To prime filter system and purge air from water line,
continueushingthesystemforapproximately3minutes
toassurethatthepurestwaterpossibleisstoredinthe
watertank.There will be noticeable spurts and sputters
as the system pushes air out through the system and
out the dispenser nozzle. This is normal.
System Startup:
Watersupplydoesnotneedtobeturnedoff,however,donot
useiceandwaterdispenserwhileinstallinglter.Thelter
cartridgehasalreadybeeninstalledinthelterhousingatthe
factory.RefertotheHow to Prime the Water Supply System
sectiontoproperlyllthesystemwithwater.
Thissystemshouldnotbeusedonwaterthatis
microbiologicallyunsafeorwithwaterofunknownqualityunless
thewaterhasbeenadequatelydisinfectedbeforeorafter
travelingthroughtheltrationsystem.Systemscertiedforcyst
reductionmaybeusedondisinfectedwatersthatmaycontain
lterablecysts.
•RatedCapacity-400gallons
•Ratedserviceow-.5GPM
•Maximum/MinimumRatedPressure-100/30PSI
•Maximum/MinimumOperatingTemp.-100°/33°F